Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
TENANT ACCESS TO SERVICE | 8125 S COLFAX AVE | COMPLAINT | FAILED | View | |
CIRCUIT ONE UNIT ONLY | MAINTENANCE MAN LIVING IN BASEMENT, ILLEGAL DWELLING UNIT | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
FIRE & WATER DAMAGE | LIGHT FIXTURE KITCHEN 2ND FLOOR | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 2ND FLOOR REAR BED ROOM,OPEN GROUND AND NOT SECURE PAINTED RECEPTACLES ALSO | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | BATH ROOM AND FRONT BED ROOM 2ND FLOOR | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | POST ADDRESS ON BUILDING. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATION EXTERIOR WALL MORTAR MISSING. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
ILLUMINATE EXIT AREAS | EXTERIOR PORCH LIGHTS BROKEN. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO INTERIOR AND APARTMENTS. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH PARAPET - WASHED OUT MORTAR. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | SOUTH MIDDLE WINDOW SASHES - 1ST THROUGH 3RD - WEATHERED WITH PEELING PAINT. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2005 THROUGH 2011. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
NO POSTED ADDRESS | BUILDING ADDRESS - MISSING. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST AT 1ST - WINDOW - BROKEN PANE. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
REPUTTY WINDOW PANES | NORTH WINDOWS - CRACKED , BROKEN , AND MISSING PUTTY. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
INSECTS | 2ND FLOOR NORTH APARTMENT - BED BUG INFESTATION THROUGHOUT . PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT , BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
ROACHES | 2ND FLOOR NORTH APARTMENT - KITCHEN - ROACHES. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
MICE/RODENTS | 2ND FLOOR NORTH APARTMENT - MICE. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - MOST APARTMENTS - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS . UNABLE TO INSPECT ALL INTERIOR STAIRWAYS. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE SLABS AND CONCRETE BASES - FOUNDATION STATUS UNKNOWN. DECK JOISTS ONLY NAILED TO RIM JOISTS AND LEDGER BEAMS, SPACED 19'' ON CENTERS. LEDGER BEAMS ONLY NAILED TO BUILDING. BEAMS ONLY NAILED TO COLUMNS. COLUMNS WITH LAP SPLICES ONLY 8'' LONG AND ONLY NAILED. COLUMNS OVERNOTCHED. STRINGERS ONLY NAILED TO HEADER JOISTS. LOOSE HAND AND GUARDRAILS. SOME GUARDRAILS ONLY 35'' HIGH. PORCH SWAYS AND IS UNSTABLE. DECKING IS ROTTED AND BUCKLED. STAIR TREADS ARE SPLIT AND WORN. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | WEST EXTERIOR WALL, 3RD FLR.; BUCKLING OUT [SUBMIT PERMITS TO RESET BRICKS.NORTH AND SOUTH EXTERIOR WALLS; MORTAR MISSING.ENCLOSE PORCH EXTERIOR WALL; SIDING BROKEN AND BUCKLING OUT. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | CANOPY IS NEEDED TO PROTECT SIDEWALK. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | PORCH AREA; JUNK AND DEBRIS. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH 3RD FLR.WINDOW FRAME; ROTTED. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | 18-27-570.8 PROVIDE GFCI PROTECTION KITCHENS AND BATHS | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWAY - STAIR RAIL 2ND TO 3RD - BALUSTERS MISSING . | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | SOUTH MIDDLE WINDOWS - 1ST THROUGH 3RD - FRAMES - WEATHERED WITH PEELING PAINT. | 8125 S COLFAX AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR. | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |
SYSTEM III | 8125 S COLFAX AVE | COMPLAINT | FAILED | View |