The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | INSUFFICIENT HEAT 7446 #1 56 DEGREES | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 7446 #1 ELECTRIC HEATER | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 7446 #1 ONLY SOME OF RADIATORS | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER 7446 #1 | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR 7446 #1 | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | EAST ELEVATION / ALL LINTELS - RUSTED SAGGING AND DETERIORATED. PLANS AND PERMIT REQUIRED FOR ALL LINTEL REPLACEMENT. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL EVLEVATIONS / EXTERIOR WALLS - EXTREME MASONRY FRACTURES WITH LOOSE AND FALLEN BRICKS. NORTH EXTERIOR WALL AT 2ND FLOOR HAS COLLPASED TO THE GROUND. PLANS AND PERMIT REQUIRED FOR ALL MASONRY REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION / 2 STORY WOOD PORCH / COLUMNS ERECTED ON COCRETE SLAB. FOUNDATION STATUS - UNKNOWN. SOME COLUMNS HAVE CONCRETE POURED AROUND BOTTOMS OF COLUMNS THAT ARE CRACKED AND SPALLING. STAITR LANDING - FASTENED TO COLUMNS WITH NAILS ONLY. UPPER ENDS OF STRINGERS - FASTENED WITH SCREWS ONLY. STAIR TREADS AND RISERS - SPLITTING AND CRACKING. ENTIRE STRUCTURE MOVES WHEN SHAKEN. PLANS AND PERMIT REQUIRED TO REPLACE 2 STORY WOOD PORCH. | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | EAST ELEVATION / CORNICE - SHIFTING WITH WASHED OUT MORTAR. | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST AND WEST ELEVATIONS / WINDOWS - BOARDED WITH PLYWOOD AT VARIOUS LOCATIONS. | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH SOUTH AND EAST ELEVATIONS / PARAPET - SPALLING MASONRYU WITH WASHED OUT MORTAR. NORTHEAST CORNER - FRACTURED AND PIUILLING AWAY FROM BUILDING. CORNER IS ON THE VERGE OF COLLAPSE. PLANS AND PERMIT REQUIRED FOR ALL MASONRY REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | EAST ELEVATION / FRONT OF BUILDING / INSTALL PROTECTIVE CANOPY OVER PUBLIC SIDEWALK. PERMIT ISSUED BY DEPT. OF TRANSPORTION REQUIRED FOR SUCH INSTALLATION. | 7446 S HARVARD AVE | COMPLAINT | FAILED | View |