The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCH IMPROPER STRING CONNECTIONS,IMPROPER BEAM/UPRIGHT CONNECTIONS, RAILS LOW/DEFLECT, JOISTS OVER SPANNED PLANS AND PERMITS REQUIRED FOR REPAIRS | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIR- ROTTING, BUCKLING DECK. ROTTING RAILS ANCHORED TO OTHER WOOD MEMBERS WITH NAILS AND/OR SCREWS ONLY. LOOSE PICKETS. BEAMS AND COLUMNS ANCHORED WITH NAILS ONLY. JOISTS ANCHORED WITH NAILS ONLY. STRINGERS ANCHORED WITH NAILS ONLY. 2X6 JOISTS SPAN 7' 6". 2X6 BEAMS SPAN 5' 6". 6" PICKET SPACING. OBTAIN PERMIT. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR EAVES | FRONT PORCH EAVES, SOFFIT AND FASCIA- ROTTING AND SEPARATING ON SOUTH SIDE NEXT TO BUILDING. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR- SIDING - LOOSE, TORN. SOUTH GANG WAY AT BASEMENT- FRACTURES, SPALLING BRICK, ERODING AND LOOSE MORTAR. | 3345 N TROY ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALK, SIDE SERVICE WALK- FRACTURES, UNEVEN, VOIDS. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE- NO OVERHEAD DOOR. BROKEN SERVICE DOOR. OPEN ELECTRICAL BOX INSIDE WEST WALL- EXPOSED WIRES. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT EXTERIOR DOOR- NO STRIKE PLATE, DOOR DOES NOT SECURE. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW WEST ELEVATION AT 3. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH- GUARD RAILS 39" IN HEIGHT, SPAN 10' 6"- DEFLECTING, MISSING PICKETS. 2X8 JOISTS SPAN 10' 6". SOUTH SIDE UNDER LOOKOUT BEAM A 2X4 IS LOOSE AND HANGING OFF STRUCTURE. STRINGERS ANCHORED WITH NAILS ONLY. BEAM AND COLUMN CONNECTIONS ANCHORED WITH NAILS ONLY. 6X6 LOOKOUT BEAMS SPAN 7' 6". LANDING JOISTS ANCHORED WITH NAILS ONLY. SINGLE 2X6 STRINGER HEADER SPANS 7' 6". 2X4 LANDING JOISTS SPAN 3' 9" INSTALLED AT 2' ON CENTERS. OBTAIN COMPLETE PLAN AND PERMIT. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIR- ROTTING, BUCKLING DECK. ROTTING RAILS ANCHORED TO OTHER WOOD MEMBERS WITH NAILS AND/OR SCREWS ONLY. LOOSE PICKETS. BEAMS AND COLUMNS ANCHORED WITH NAILS ONLY. JOISTS ANCHORED WITH NAILS ONLY. STRINGERS ANCHORED WITH NAILS ONLY. 2X6 JOISTS SPAN 7' 6". 2X6 BEAMS SPAN 5' 6". 6" PICKET SPACING. OBTAIN PERMIT. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | REAR- SIDING - LOOSE, TORN. SOUTH GANG WAY AT BASEMENT- FRACTURES, SPALLING BRICK, ERODING AND LOOSE MORTAR. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE- NO OVERHEAD DOOR. BROKEN SERVICE DOOR. OPEN ELECTRICAL BOX INSIDE WEST WALL- EXPOSED WIRES. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT EXTERIOR DOOR- NO STRIKE PLATE, DOOR DOES NOT SECURE. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW WEST ELEVATION AT 3. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR PORCH- GUARD RAILS 39" IN HEIGHT, SPAN 10' 6"- DEFLECTING, MISSING PICKETS. 2X8 JOISTS SPAN 10' 6". SOUTH SIDE UNDER LOOKOUT BEAM A 2X4 IS LOOSE AND HANGING OFF STRUCTURE. STRINGERS ANCHORED WITH NAILS ONLY. BEAM AND COLUMN CONNECTIONS ANCHORED WITH NAILS ONLY. 6X6 LOOKOUT BEAMS SPAN 7' 6". LANDING JOISTS ANCHORED WITH NAILS ONLY. SINGLE 2X6 STRINGER HEADER SPANS 7' 6". 2X4 LANDING JOISTS SPAN 3' 9" INSTALLED AT 2' ON CENTERS. OBTAIN COMPLETE PLAN AND PERMIT. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY INTERIOR. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
REMOVE | ILLEGAL BASEMENT UNIT UNDERGOING GUT REHAB IN ORIGINAL 3 STORY 3 UNIT BUILDING IN RS-3 ZONING DISTRICT. BASEMENT PARTIONS REMOVED, BASEMENT SLAB REMOVED AND BASEMENT LEVEL HAS BEEN DUG DOWN APPROX. 18'' (ORIGINAL CEILING HEIGHT APPROX 6' 9'' NOW INCREASED TO 8' 3'' APPROX). ELECTRIC AND PLUMBING WORK INCLUDED. PROHIBITED USE;17-2-0204 | 3345 N TROY ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | ILLEGAL BASEMENT UNIT UNDERGOING GUT REHAB; PARTITIONS REMOVED, BASEMENT SLAB REMOVED AND DUG DOWN 18'' DEEPER, PLUMBING AND ELECTRICAL WORK. OBTAIN PLAN AND PERMIT TO RESTORE BASEMENT TO ORIGINAL STATE. | 3345 N TROY ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | STOP WORK; GUT REHAB OF ILLEGAL BASEMENT UNIT INCLUDING PLUMBING, ELECTRIC, REMOVED SLAB AND LOWERED FLOOR 18''. 13-32-035, 13-12-080, 13-12-050.OBTAIN PLAN AND PERMIT TO RESTORE BASEMENT TO ORIGINAL STATE. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR 3 STORY WOOD PORCH; GUARD RAILS 39'' IN HEIGHT SPAN 10' 6''- DEFLECTING, PICKETS MISSING. 2X8 JOISTS SPAN 10' 6''. SOUTH SIDE UNDER LOOKOUT BEAM 2X4 LOOSE AND HANGING OFF OF STRUCTURE. STRINGERS ANCHORED WITH NAILS ONLY. BEAM AND COLUMN CONNECTIONS ANCHORED WITH NAILS ONLY. 6X6 LOOKOUT BEAMS SPAN 7' 6''. LANDING JOISTS ANCHORED/ FASTENED WITH NAILS ONLY. SINGLE 2X6 STRINGER HEADER SPANS 7' 6''. 2X4 LANDING LOISTS SPAN 3' 9'' INSTALLED AT 2' CENTERS. OBTAIN PLAN AND PERMIT. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST ELEVATION SOUTH WEST WIDOW OF 3RD FLOOR BAY LINTEL DETERIORATING. | 3345 N TROY ST | COMPLAINT | FAILED | View |
ARMORED CABLE | REPLACE AND REMOVE DEFECTIVE ARMORED CABLE THROUGHOUT ALL UNITS AND IN PANEL ROOM OF ALL UNITS | 3345 N TROY ST | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | INSTALL COVER FOR ELECTRICAL PANEL ON 2ND FLOOR | 3345 N TROY ST | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | INSTALL PROPER WATER GROUND TO SERVICE | 3345 N TROY ST | COMPLAINT | FAILED | View |
DEFECTIVE POWER SERVICE | DEFECTIVE SERVICE, ALL EQUIPMENT MUST BE RATED FOR USE. (SERVICE EQUIPMENT OUTSIDE) | 3345 N TROY ST | COMPLAINT | FAILED | View |
SERVICE MUST BE INSTALLED ON 1ST FLOOR OR BASEMENT OF BUILDING 18-27-230.70 | 3345 N TROY ST | COMPLAINT | FAILED | View | |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF NOT ENOUGH HEAT.UNVERIFIED OCCUPANCY AND DETECTORS. | 3345 N TROY ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S I.D SIGN POSTED. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR OF PROPERTY / 3 STORY WOODEN PORCH - ALAGE GROWTH ON 2ND AND 3RD FLOOR LANDINGS. 1ST FLOOR, FLOOR BOARD WARPED AND TWISTED. 3RD FLOOR BALUSTERS WARPED AND OR WEATHERED. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / EXTERIOR WALL - GROUND LEVEL, WASHED OUT MORTAR. FRONT OF BUILDING / EXTERIOR WALL - VERTICAL CRACK AT FRONT FACE SOUTH SECTION OF WALL. STEP FRACTURES NEAR WINDOWS. | 3345 N TROY ST | COMPLAINT | FAILED | View |
REPAIR FENCE | SOUTH ELEVATION / REAR OF PROPERTY / FENCE - IRON FENCE, LEANING, MISSING POST. WIRE TIED TO CHAIN LINK FENCE. | 3345 N TROY ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / NO OWNER'S ID SIGN POSTED. | 3345 N TROY ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING / NO ENTRY,UNVERIFIED DETECTORS,UNABLE TO VERIFY COMPLAINT OF FROZEN WATER PIPE IN BASEMENT. | 3345 N TROY ST | COMPLAINT | FAILED | View |
PARAPET | NORTH ELEVATION / PARAPET WALL - WASHED OUT MORTAR AND OR OPEN MORTAR JOINTS. | 3345 N TROY ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALK, SIDE SERVICE WALK- FRACTURES, UNEVEN, VOIDS. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
REPAIR EAVES | FRONT PORCH EAVES, SOFFIT AND FASCIA- ROTTING AND SEPARATING ON SOUTH SIDE NEXT TO BUILDING. | 3345 N TROY ST | COMPLAINT | CLOSED | View |
NO PERMIT WIRING | PROVIDE PERMITS FOR ALL ELECTRICAL WORK PERFORMED IN BASEMENT UNIT WITHOUT PERMITS. ALSO PERMIT NEEDED FOR WORK DONE IN UNITS 1, 2 AND 3 CAN LIGHTING, INSTALLING OF PANELS AND INSTALLING OF OUTLETS FOR WASHER AND DRYERS IN CLOSETS IN EACH UNIT | 3345 N TROY ST | COMPLAINT | FAILED | View |