Last Modification Date: 2024-08-30 @ 5:12 PM
PIN: 13243110050000
Property Address: 3345 N TROY ST
City - Zip: CHICAGO - 60618
2023 Property Class:
2023 Township: -
2023 Neighborhood:
2023 Tax District:
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 37 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM REAR PORCH IMPROPER STRING CONNECTIONS,IMPROPER BEAM/UPRIGHT CONNECTIONS, RAILS LOW/DEFLECT, JOISTS OVER SPANNED PLANS AND PERMITS REQUIRED FOR REPAIRS 3345 N TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT EXTERIOR STAIR- ROTTING, BUCKLING DECK. ROTTING RAILS ANCHORED TO OTHER WOOD MEMBERS WITH NAILS AND/OR SCREWS ONLY. LOOSE PICKETS. BEAMS AND COLUMNS ANCHORED WITH NAILS ONLY. JOISTS ANCHORED WITH NAILS ONLY. STRINGERS ANCHORED WITH NAILS ONLY. 2X6 JOISTS SPAN 7' 6". 2X6 BEAMS SPAN 5' 6". 6" PICKET SPACING. OBTAIN PERMIT. 3345 N TROY ST COMPLAINT FAILED View
REPAIR EAVES FRONT PORCH EAVES, SOFFIT AND FASCIA- ROTTING AND SEPARATING ON SOUTH SIDE NEXT TO BUILDING. 3345 N TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL REAR- SIDING - LOOSE, TORN. SOUTH GANG WAY AT BASEMENT- FRACTURES, SPALLING BRICK, ERODING AND LOOSE MORTAR. 3345 N TROY ST COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY REAR SERVICE WALK, SIDE SERVICE WALK- FRACTURES, UNEVEN, VOIDS. 3345 N TROY ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE- NO OVERHEAD DOOR. BROKEN SERVICE DOOR. OPEN ELECTRICAL BOX INSIDE WEST WALL- EXPOSED WIRES. 3345 N TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT EXTERIOR DOOR- NO STRIKE PLATE, DOOR DOES NOT SECURE. 3345 N TROY ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOW WEST ELEVATION AT 3. 3345 N TROY ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH- GUARD RAILS 39" IN HEIGHT, SPAN 10' 6"- DEFLECTING, MISSING PICKETS. 2X8 JOISTS SPAN 10' 6". SOUTH SIDE UNDER LOOKOUT BEAM A 2X4 IS LOOSE AND HANGING OFF STRUCTURE. STRINGERS ANCHORED WITH NAILS ONLY. BEAM AND COLUMN CONNECTIONS ANCHORED WITH NAILS ONLY. 6X6 LOOKOUT BEAMS SPAN 7' 6". LANDING JOISTS ANCHORED WITH NAILS ONLY. SINGLE 2X6 STRINGER HEADER SPANS 7' 6". 2X4 LANDING JOISTS SPAN 3' 9" INSTALLED AT 2' ON CENTERS. OBTAIN COMPLETE PLAN AND PERMIT. 3345 N TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT EXTERIOR STAIR- ROTTING, BUCKLING DECK. ROTTING RAILS ANCHORED TO OTHER WOOD MEMBERS WITH NAILS AND/OR SCREWS ONLY. LOOSE PICKETS. BEAMS AND COLUMNS ANCHORED WITH NAILS ONLY. JOISTS ANCHORED WITH NAILS ONLY. STRINGERS ANCHORED WITH NAILS ONLY. 2X6 JOISTS SPAN 7' 6". 2X6 BEAMS SPAN 5' 6". 6" PICKET SPACING. OBTAIN PERMIT. 3345 N TROY ST COMPLAINT CLOSED View
REPAIR EXTERIOR WALL REAR- SIDING - LOOSE, TORN. SOUTH GANG WAY AT BASEMENT- FRACTURES, SPALLING BRICK, ERODING AND LOOSE MORTAR. 3345 N TROY ST COMPLAINT CLOSED View
REPAIR/REBUILD GARAGE OR SHED GARAGE- NO OVERHEAD DOOR. BROKEN SERVICE DOOR. OPEN ELECTRICAL BOX INSIDE WEST WALL- EXPOSED WIRES. 3345 N TROY ST COMPLAINT CLOSED View
REPAIR EXTERIOR DOOR HARDWARE FRONT EXTERIOR DOOR- NO STRIKE PLATE, DOOR DOES NOT SECURE. 3345 N TROY ST COMPLAINT CLOSED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOW WEST ELEVATION AT 3. 3345 N TROY ST COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR PORCH- GUARD RAILS 39" IN HEIGHT, SPAN 10' 6"- DEFLECTING, MISSING PICKETS. 2X8 JOISTS SPAN 10' 6". SOUTH SIDE UNDER LOOKOUT BEAM A 2X4 IS LOOSE AND HANGING OFF STRUCTURE. STRINGERS ANCHORED WITH NAILS ONLY. BEAM AND COLUMN CONNECTIONS ANCHORED WITH NAILS ONLY. 6X6 LOOKOUT BEAMS SPAN 7' 6". LANDING JOISTS ANCHORED WITH NAILS ONLY. SINGLE 2X6 STRINGER HEADER SPANS 7' 6". 2X4 LANDING JOISTS SPAN 3' 9" INSTALLED AT 2' ON CENTERS. OBTAIN COMPLETE PLAN AND PERMIT. 3345 N TROY ST COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION NO ENTRY INTERIOR. 3345 N TROY ST COMPLAINT CLOSED View
REMOVE ILLEGAL BASEMENT UNIT UNDERGOING GUT REHAB IN ORIGINAL 3 STORY 3 UNIT BUILDING IN RS-3 ZONING DISTRICT. BASEMENT PARTIONS REMOVED, BASEMENT SLAB REMOVED AND BASEMENT LEVEL HAS BEEN DUG DOWN APPROX. 18'' (ORIGINAL CEILING HEIGHT APPROX 6' 9'' NOW INCREASED TO 8' 3'' APPROX). ELECTRIC AND PLUMBING WORK INCLUDED. PROHIBITED USE;17-2-0204 3345 N TROY ST COMPLAINT FAILED View
WORK NOT ALLOWED ILLEGAL BASEMENT UNIT UNDERGOING GUT REHAB; PARTITIONS REMOVED, BASEMENT SLAB REMOVED AND DUG DOWN 18'' DEEPER, PLUMBING AND ELECTRICAL WORK. OBTAIN PLAN AND PERMIT TO RESTORE BASEMENT TO ORIGINAL STATE. 3345 N TROY ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR STOP WORK; GUT REHAB OF ILLEGAL BASEMENT UNIT INCLUDING PLUMBING, ELECTRIC, REMOVED SLAB AND LOWERED FLOOR 18''. 13-32-035, 13-12-080, 13-12-050.OBTAIN PLAN AND PERMIT TO RESTORE BASEMENT TO ORIGINAL STATE. 3345 N TROY ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR EXTERIOR 3 STORY WOOD PORCH; GUARD RAILS 39'' IN HEIGHT SPAN 10' 6''- DEFLECTING, PICKETS MISSING. 2X8 JOISTS SPAN 10' 6''. SOUTH SIDE UNDER LOOKOUT BEAM 2X4 LOOSE AND HANGING OFF OF STRUCTURE. STRINGERS ANCHORED WITH NAILS ONLY. BEAM AND COLUMN CONNECTIONS ANCHORED WITH NAILS ONLY. 6X6 LOOKOUT BEAMS SPAN 7' 6''. LANDING JOISTS ANCHORED/ FASTENED WITH NAILS ONLY. SINGLE 2X6 STRINGER HEADER SPANS 7' 6''. 2X4 LANDING LOISTS SPAN 3' 9'' INSTALLED AT 2' CENTERS. OBTAIN PLAN AND PERMIT. 3345 N TROY ST COMPLAINT FAILED View
REPAIR LINTELS WEST ELEVATION SOUTH WEST WIDOW OF 3RD FLOOR BAY LINTEL DETERIORATING. 3345 N TROY ST COMPLAINT FAILED View
ARMORED CABLE REPLACE AND REMOVE DEFECTIVE ARMORED CABLE THROUGHOUT ALL UNITS AND IN PANEL ROOM OF ALL UNITS 3345 N TROY ST COMPLAINT FAILED View
CLOSE BOX OPENINGS INSTALL COVER FOR ELECTRICAL PANEL ON 2ND FLOOR 3345 N TROY ST COMPLAINT FAILED View
PROPER SIZE GRD ELECTRODE COND INSTALL PROPER WATER GROUND TO SERVICE 3345 N TROY ST COMPLAINT FAILED View
DEFECTIVE POWER SERVICE DEFECTIVE SERVICE, ALL EQUIPMENT MUST BE RATED FOR USE. (SERVICE EQUIPMENT OUTSIDE) 3345 N TROY ST COMPLAINT FAILED View
SERVICE MUST BE INSTALLED ON 1ST FLOOR OR BASEMENT OF BUILDING 18-27-230.70 3345 N TROY ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF NOT ENOUGH HEAT.UNVERIFIED OCCUPANCY AND DETECTORS. 3345 N TROY ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S I.D SIGN POSTED. 3345 N TROY ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR OF PROPERTY / 3 STORY WOODEN PORCH - ALAGE GROWTH ON 2ND AND 3RD FLOOR LANDINGS. 1ST FLOOR, FLOOR BOARD WARPED AND TWISTED. 3RD FLOOR BALUSTERS WARPED AND OR WEATHERED. 3345 N TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION / EXTERIOR WALL - GROUND LEVEL, WASHED OUT MORTAR. FRONT OF BUILDING / EXTERIOR WALL - VERTICAL CRACK AT FRONT FACE SOUTH SECTION OF WALL. STEP FRACTURES NEAR WINDOWS. 3345 N TROY ST COMPLAINT FAILED View
REPAIR FENCE SOUTH ELEVATION / REAR OF PROPERTY / FENCE - IRON FENCE, LEANING, MISSING POST. WIRE TIED TO CHAIN LINK FENCE. 3345 N TROY ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING / NO OWNER'S ID SIGN POSTED. 3345 N TROY ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING / NO ENTRY,UNVERIFIED DETECTORS,UNABLE TO VERIFY COMPLAINT OF FROZEN WATER PIPE IN BASEMENT. 3345 N TROY ST COMPLAINT FAILED View
PARAPET NORTH ELEVATION / PARAPET WALL - WASHED OUT MORTAR AND OR OPEN MORTAR JOINTS. 3345 N TROY ST COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY REAR SERVICE WALK, SIDE SERVICE WALK- FRACTURES, UNEVEN, VOIDS. 3345 N TROY ST COMPLAINT CLOSED View
REPAIR EAVES FRONT PORCH EAVES, SOFFIT AND FASCIA- ROTTING AND SEPARATING ON SOUTH SIDE NEXT TO BUILDING. 3345 N TROY ST COMPLAINT CLOSED View
NO PERMIT WIRING PROVIDE PERMITS FOR ALL ELECTRICAL WORK PERFORMED IN BASEMENT UNIT WITHOUT PERMITS. ALSO PERMIT NEEDED FOR WORK DONE IN UNITS 1, 2 AND 3 CAN LIGHTING, INSTALLING OF PANELS AND INSTALLING OF OUTLETS FOR WASHER AND DRYERS IN CLOSETS IN EACH UNIT 3345 N TROY ST COMPLAINT FAILED View