Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR INTERIOR WALLS/CEILING | EAST STAIRWAY AT 3RD HOLE. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | EAST STAIRWAY AT 3RD MISSING SMOKE DETECTOR. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | EAST STAIRWAY AT 3RD EXPOSED WIRES. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2439 TO VERIFY OCCUPANCY- SMOKE AND CARBON MONOXIDE DETECTOR. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING YEAR 2004 THRU 2008. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH COLUMNS MISSING FOOTINGS, STRINGERS MISSING BOLTS, 2X8 JOISTS ROTTED, SCABBED AND UNDERSIZED FOR 12-0 SPAN- FLR BUCKLED AND ROTTED AREAS, TREADS NARROW AND LOOSE WITH DIFFERENT HEIGHTS OF RISERS, LOOSE RAILING- PROVIDE PLAN AND PERMIT TO REPAIR OR REPLACE. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTH ELEVATION LINTELS ALL LEVELS RUSTED, FLAKING OR PARTLY MISSING | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | STEP FRACTURES FROM SECOND FLOOR TO THIRD FLOOR AND FROM THIRD TO PARAPET ON NORTH ELEVATION AND SOUTH. MASONRY PERMITS REQUIRED. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | SOUTH LOT AND REAR YARD LOADED WITH DEBRIS | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | EAST STAIRWAY AT THIRD FLOOR, HOLE. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | EAST STAIRWAY NOW WORKING SMOKE DETECTORS. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | EAST STAIRWAY THIRD FLOOR EXPOSED WIRING | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR PORCH SYSTEM WITH THE FOLLOWING DEFECTS, ROTTEN JOISTS, JOIST OVER SPANNED 13', NO BOLTS BEAM TO COLUMN CONNECTION, NO BOLTS STRINGERS TO SUPPORT POSTS, NO VISIBLE FOOTINGS FOR 6X6 COLUMNS, 2X6 SCABBED BELOW BEAM TO COLUMN CONNECTIONS, TREADS LOOSE, ROTTEN, DIFFERENT SIZE THRU-OUT, GUARDRAILS MISSING ON NORTH ELEVATION OF PORCH, CHAIN LINK FENCE IN ITS PLACE. PLANS AND PERMITS REQUIRED. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION STAIR SYSTEM WITH FOLLOWING DEFECTS, NO VISIBLE FOOTINGS FOR 6X6 COLUMNS, NO BOLTS STRINGER TO SUPPORT POSTS OR BUILDING, TREADS LOOSE, DIFFERENT SIZE THRU-OUT, HAND RAILS DEFLECT UNDER LOAD. PLANS AND PERMITS REQUIRED FOR REPAIRS OR REPLACEMENT. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW | FOUR WINDOWS BOARDED UP ON FIRST FLOOR NORTH ELEVATION. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | 1ST FLOOR VACANT STORE ACCUMULATION OF JUNK AND DEBRIS. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR REAR PORCH AND SOUTH SIDE ELEVATION STAIR SYSTEM. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH ELEVATION STAIR SYSTEM BLOCKED AT 1ST AND 2 ND FLOOR LANDINGS. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | !ST FLOOR VACANT STORE- ACCUMULATION OF JUNK AND DEBRIS | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR APARTMENT SMOKE DETECTOR MISSING. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR APARTMENT CARBON MONOXIDE DETECTOR MISSING BATTERIES. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR YARD MASONARY FENCE UNDER CONSTRUCTION-NO PERMIT POSTED. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 1358 N ARTESIAN AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 1358 N ARTESIAN AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 1358 N ARTESIAN AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 1358 N ARTESIAN AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 1358 N ARTESIAN AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 1358 N ARTESIAN AVE | COMPLAINT | CLOSED | View | |
REPAIR LINTELS | NORTH ELEVATION LINTELS ALL LEVELS RUSTED, FLAKING OR PARTLY MISSING | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | REAR APARTMENT DOORS (WEST) - MISSING SCREEN DOORS. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE FOR 2016 ANNUAL INSPECTION TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | THE STONE COURSE OF MASONRY BELOW THE PARAPETT WALL (3RD LEVEL-NORTH AND EAST ELEVATIONS) HAS SEVERELY DEGRADED, LOOSE AND DISPLACED, HEAVY STONE PIECES; SEVERAL OF WHICH HAVE FALLEN TO THE SIDEWALK. THIS INSPECTION WAS THE RESULT OF AN EMERGENCY DISPATCH CALL. SOME OF THE REMAINING STONEWORK IS IN A STATE OF POTENTIAL COLLAPSE (SOME OF THIS LOOSE STONEWORK IS ABOVE THE 1358 ENTRANCE DOOR). THIS CONDITION REMAINS DANGEROUS AND HAZARDOUS. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 1358 N ARTESIAN AVE | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | THIS REPORT SHOULD FOCUS ON THE STONE WATER COURSE AT THE 3RD LEVEL OF THE NORTH AND EAST ELEVATIONS. | 1358 N ARTESIAN AVE | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | A PROTECTIVE CANOPY IS NEEDED ACROSS THE ENTIRE WIDTH OF THE NORTH AND SOUTH ELEVATIONS DUE TO UNSTABLE STONEWORK (SOME OF WHICH HAS FALLEN TO THE PUBLIC SIDEWALK). | 1358 N ARTESIAN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH COLUMNS MISSING FOOTINGS,STRINGERS MISSING BOLTS,2X8 FLOOR JOISTS ROTTED,SCABBED AND UNDERSIZED FOR 12'SPAN,FLOORING BUCKLE IN ROTTED AREAS,TREADS NARROW AND LOOSE WITH DIFFERENT HIGHS OF RISERS,LOOSE RAILINGS.SOUTH ELEVATION STAIR SYSTEM UPRIGHTS MISSING FOOTINGS,WARPED OUT OF PLUMB,TREADS 8"WIDE,RISERS LOOSE AND DIFFERENT HIGHTS,STRINGERS MISSING BOLTS,UPRIGHTS IMPROPER SPLICE CONNECTION,STAIRS GOING TO ROOF MISSING RAILINGS, | 1358 N ARTESIAN AVE | PERIODIC | FAILED | View |