Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR LINTELS | 1ST TO 2ND FLOOR WINDOW RUSTED LINTELS | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2ND FLOOR REAR BROKEN WINDOW PANE | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | VACANT AND SECURED. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
SUBMIT PLANS/GET VENT PERMIT | SUBMIT PLAN/OBTAIN PERMIT FOR CHANGE IN USE OF BUILDING INCLUDE LAYOUT OF BUILDING WITH ALL AREAS AND SHOW HOW VENTILATION HEATING WILL BE PROVIDED PER CODE 13-32-020,13-32-130,13-40-010,18-28-403.14 | 5035 W FOSTER AVE | COMPLAINT | PASSED | View |
NO SUPPLY AIR F/BSMNT/CELLAR | OBTAIN PERMIT FOR NEW HEATING EQUIPMENT INSTALLED OR PLANNED TO BE INSTALLED 13-40-140,13-32-270 | 5035 W FOSTER AVE | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | ARRANGE INSPECTION AFTER PERMIT IS OBTAINED 13-12-100,13-20-290,13-32-270 | 5035 W FOSTER AVE | COMPLAINT | PASSED | View |
REPAIR LINTELS | RUSTED WINDOW LINTELS NORTH 1ST AND 2ND FLOOR | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | 1. CATEGORY I TEST AS REQUIRED BY CODE. 2. REPAIR TOP FLOOR HALL BUTTON PIPING. 3. CLEAN ELEVATOR PIT. 4. PROVIDE WORKING CLEARANCE AROUND CONTROLLER AND PUMP UNIT. 18-30-010, 13-20-120. EV002119 | 5035 W FOSTER AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PERFORM CATEGORY 1 TEST. TAG AND DOCUMENT AS REQUIRED. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR OR REPLACE DEFECTIVE ALARM BUTTON - SHOCK HAZARD. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROPERLY SECURE DOOR UNLOCKING DEVICE AT BASEMENT LEVEL. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ADD HYDRAULIC OIL AS REQUIRED TO REACH TOP FLOOR WITHOUT CAVITATING. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | CLEAN ELEVATOR PIT AND MACHINE ROOM. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | FIX ALARM BELL BUTTON | 5035 W FOSTER AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PATCH ALL HOLES IN HOIST WAY | 5035 W FOSTER AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | CLEAN OIL FROM PIT. | 5035 W FOSTER AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL EMERGENCY TELEPHONE | 5035 W FOSTER AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL CODE DATA TAG | 5035 W FOSTER AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REMOVE SPRINKLER FROM ELEVATOR MACHAINE ROOM | 5035 W FOSTER AVE | PERIODIC | PASSED | View |
INSTALL EXIT SIGN | 1ST FLOOR ENTRANCE BY WEST DOCK, - MISSING EMERGENCY EXIY SIGN. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
PROVIDE | THROUGHOUT 1ST FLOOR SEVERAL STEEL BEAMS MISSING FIRE PROOFING. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | AT 1ST FLOOR WEST DOCK, RAMP IS POORLY CONSTRUCTED, - GUARDRAILS ARE LESS THEN 42" IN HEIGHT, - GUARD RAILS ARE HORIZONTAL CREATING THE LADDER EFECT, - RAMP IS MADE WITH COMBUSTIBLE MATERIALS, - PLANS AND PERMIT ARE REQUIRED TO REPAIR RAMP. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER¿S INFORMATION. | 5035 W FOSTER AVE | PERIODIC | FAILED | View |