Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 4:58 PM
PIN: 13094010050000
Property Address: 5035 W FOSTER AVE
City - Zip: CHICAGO - 60630
2023 Property Class: 597
2023 Township: 71 - Jefferson
2023 Neighborhood: 71060
2023 Tax District: 71108
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 23 Violations
Violation Inspector Comments Address Category Status View
REPAIR LINTELS 1ST TO 2ND FLOOR WINDOW RUSTED LINTELS 5035 W FOSTER AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 2ND FLOOR REAR BROKEN WINDOW PANE 5035 W FOSTER AVE PERIODIC FAILED View
NOTIFY DOB, USE OF VACANT LND VACANT AND SECURED. 5035 W FOSTER AVE PERIODIC FAILED View
SUBMIT PLANS/GET VENT PERMIT SUBMIT PLAN/OBTAIN PERMIT FOR CHANGE IN USE OF BUILDING INCLUDE LAYOUT OF BUILDING WITH ALL AREAS AND SHOW HOW VENTILATION HEATING WILL BE PROVIDED PER CODE 13-32-020,13-32-130,13-40-010,18-28-403.14 5035 W FOSTER AVE COMPLAINT PASSED View
NO SUPPLY AIR F/BSMNT/CELLAR OBTAIN PERMIT FOR NEW HEATING EQUIPMENT INSTALLED OR PLANNED TO BE INSTALLED 13-40-140,13-32-270 5035 W FOSTER AVE COMPLAINT PASSED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE INSPECTION AFTER PERMIT IS OBTAINED 13-12-100,13-20-290,13-32-270 5035 W FOSTER AVE COMPLAINT PASSED View
REPAIR LINTELS RUSTED WINDOW LINTELS NORTH 1ST AND 2ND FLOOR 5035 W FOSTER AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA 1. CATEGORY I TEST AS REQUIRED BY CODE. 2. REPAIR TOP FLOOR HALL BUTTON PIPING. 3. CLEAN ELEVATOR PIT. 4. PROVIDE WORKING CLEARANCE AROUND CONTROLLER AND PUMP UNIT. 18-30-010, 13-20-120. EV002119 5035 W FOSTER AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PERFORM CATEGORY 1 TEST. TAG AND DOCUMENT AS REQUIRED. 5035 W FOSTER AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR OR REPLACE DEFECTIVE ALARM BUTTON - SHOCK HAZARD. 5035 W FOSTER AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROPERLY SECURE DOOR UNLOCKING DEVICE AT BASEMENT LEVEL. 5035 W FOSTER AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA ADD HYDRAULIC OIL AS REQUIRED TO REACH TOP FLOOR WITHOUT CAVITATING. 5035 W FOSTER AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA CLEAN ELEVATOR PIT AND MACHINE ROOM. 5035 W FOSTER AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA FIX ALARM BELL BUTTON 5035 W FOSTER AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PATCH ALL HOLES IN HOIST WAY 5035 W FOSTER AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA CLEAN OIL FROM PIT. 5035 W FOSTER AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL EMERGENCY TELEPHONE 5035 W FOSTER AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL CODE DATA TAG 5035 W FOSTER AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA REMOVE SPRINKLER FROM ELEVATOR MACHAINE ROOM 5035 W FOSTER AVE PERIODIC PASSED View
INSTALL EXIT SIGN 1ST FLOOR ENTRANCE BY WEST DOCK, - MISSING EMERGENCY EXIY SIGN. 5035 W FOSTER AVE PERIODIC FAILED View
PROVIDE THROUGHOUT 1ST FLOOR SEVERAL STEEL BEAMS MISSING FIRE PROOFING. 5035 W FOSTER AVE PERIODIC FAILED View
REPAIR EXTERIOR STAIR AT 1ST FLOOR WEST DOCK, RAMP IS POORLY CONSTRUCTED, - GUARDRAILS ARE LESS THEN 42" IN HEIGHT, - GUARD RAILS ARE HORIZONTAL CREATING THE LADDER EFECT, - RAMP IS MADE WITH COMBUSTIBLE MATERIALS, - PLANS AND PERMIT ARE REQUIRED TO REPAIR RAMP. 5035 W FOSTER AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# MISSING OWNER¿S INFORMATION. 5035 W FOSTER AVE PERIODIC FAILED View