PIN: 21303310030000
Property Address: 7807 S MARQUETTE AVE
City - Zip: CHICAGO - 60649
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70100
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 4 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO ENTRY, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. 7807 S MARQUETTE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM EAST ELEVATION / 2 STORY WOOD PORCH / 6X6 COLUMNS - STACKED ON ONE ANOTHER. COLUMNS - MISSING METAL BASES. DECKING HAS HOLE NEAR 4X4 SUPPORT POST. GUARDRAILS - UNDERSIZED. STEEL HARDWARE IS RUSTED AND DETERIORATED. WEST ELEVATION / FRONT PORCH / RAILINGS - FASTENED WITH NAILS ONLY. PERMIT FOR ALL PORCH REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. WEST 1 STORY WOOD PORCH / RAILINGS - FASTENED WITH NAILS ONLY. PERMIT REQUIRED FOR ALL PORCH REPAIRS. 7807 S MARQUETTE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH - FOUNDATION STATUS UNKNOWN; 1)MISSING NEW 6X6 COLUMN (PER PLANS); 2)SISTERED 2X10 RIM JOISTS INSTEAD OF SISTERED 2X12 RIM JOISTS (PER PLANS); 3)LATERAL SWAY AT UPPERMOST LANDING; 4)SPLITTING TREADS THROUGHOUT; 5)GAPS AT BOTTOM RAIL OF HANDRAIL (G-1ST), TOPS OF SPINDLES THROUGHOUT, AND SPLICE JOINT - 6X6 COLUMNS NOT FLUSH (1ST FLOOR); 6)LOOSE DECKBOARD AT 1ST FLOOR; 7)SPINDLES CUPPING, WARPED THROUGHOUT; 8)2X8 RIM JOISTS OVEREXTENDED AT 1ST, 2ND FLOORS; 9)4X4 COLUMN (AND BOLTS) TWISTING AT 2ND FLOOR RAIL; 10)LOOSE BOLTS AT STRINGER/COLUMN CONNECTIONS; 11)UNDERSIZED BOLTS AT BASEMENT LEDGER BOARD, NOT 5/8" (PER PLANS); 12)2X6 SCAB BOARD MISSING AT STRINGER (BASEMENT/GRADE). 7807 S MARQUETTE AVE PERMIT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF APTS. - NO ENTRY, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO VERIFY COMPLAINT OF WOMAN AT BASEMENT HOUSING RACOONS, RODENTS AND CATS. UNABLE TO VERIFY CONDITION OF BASEMENT. 7807 S MARQUETTE AVE COMPLAINT FAILED View