The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MICE/RODENTS | MICE, ROOM 8,9,7 & 6 | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | NO PEEPHOLE THRU-OUT, ROOM 8,7 | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | NON-WORKING SMOKE DETECTOR, ROOM 8 | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | BROKEN ENTRANCE DOOR, ROOM 9 | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | NO FIRE EXTINGUISHERS TAG THRU-OUT | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | LOOSE TREADS & RISERS AT REAR INTERIOR STAIRWAY, 1ST FLOOR TO ATTIC FLOOR | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NO FOUNDATION FOOTING FOR THE REAR PORCH SYSTEM, 4X4 COLUMNS RESTING ON SERVICE WALKWAY | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM: NO JOIST HANGERS, NO BOLTS ON COLUMNS, RAILINGS MISSING PICKETS AT 2ND FLOOR LANDING, UNDERSIZED RAILINGS & GUARD RAILS LESS THAN 42 INCHES HIGH; FULL PLANS & PERMIT NEEDED FOR REPAIRS | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | FLAKING PAINTS ON FRONT ATTIC WINDOW FRAME & SASHES | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
ATTIC, DISCONTINUE | ATTIC FLOOR ALTERED TO FROM 3 ROOMING UNITS & 1 FULL TOILET | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
LIGHT AND VENT | NO ADEQUATE LIGHT & VENTILATION IN ATTIC FLOOR ROOMING UNITS | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' | ATTIC FLOOR TO CEILING HEIGHT LESS THAN 7 FEET, HEIGHT IS 5'3" | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
BASEMENT, DISCONTINUE | BASEMENT FLOOR ALTERED TO FORM 4 ROOMING UNITS AND A TOILET | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
STAIRWELL ENCLOSURE - BASEMENT | BASEMENT TO 1ST FLOOR INTERIOR STAIRWAY WALLS NOT ADEQUATELY ENCLOSED | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT FLOOR TO CEILING HEIGHT LESS THAN 7 FEET HIGH, MOST AREA HEIGHT SHOWS 5'6" HIGH | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
NATURAL LIGHT NEEDED | BASEMENT: NO ADEQUATE NATURAL LIGHT TO ROOMS AND HALLWAYS (13-172-150, 13-196-730M 13-200-230E) | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
PAINT SHUT | BASEMENT: NO ADEQUATE VENTILATION TO OUTER AIR, GLASS BLOCK USED IN ALL WINDOWS | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | CURLED AND MISSING SHINGLES ALL ELEVATIONS. | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | GAS SERVICE-SHUT OFF, NO HEAT PROVIDED. | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | USING PORTABLE HEATING EQUIPMENT, ELECTRICT SPACE HEATERS. | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | TO RAIL TO FENCE IN FRONT MISSING ALSO GATE AT REAR BROKEN | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO POSTING OF OWNERSHIP | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | PORCH RAILINGS AT FRONT HAVE SPACING OF PICKETS THAT EXCEED 4" CORAL TYPE RAILINGS ON NORTH END OF FRONT PORCH NOT PERMITTED | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
EGRESS | ATTIC FLOOR HAS ONLY ONE MEANS OF EGRESS | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | GAS SERVICE-SHUT OFF, NO HOT WATER FURNISHED. | 7214 S PRINCETON AVE | COMPLAINT | FAILED | View |