The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2ND AND 3RD FLOORS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION HAS BROKEN WINDOW PANE | 1701 W 79TH ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING HAS NOT BEEN REGISTERED | 1701 W 79TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PROVIDE | 15-4-880, 15-4-900 REDUCED EGRESS WEST EMPLOYEE COUNTER AREA AS FOLLOW 31" COUNTER-WALL AND DOOR OPENING AT 18 1/2 | 1701 W 79TH ST | COMPLAINT | FAILED | View |
NO BARBED WIRE ON FENCE < 8FT | WEST CHAIN LINK FENCE HAS RAZOR WIRE | 1701 W 79TH ST | COMPLAINT | FAILED | View |
REPAIR FENCE | WEST CHAIN LINK FENCE HAS DISCONNECTED TOP RAIL LOOSE WEBBING AND OUT OF PLUMB | 1701 W 79TH ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | WEST CHAIN LINK FENCE OVER 5', REDUCE HEIGHT, REMOVE, OR OBTAIN A PERMIT | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | FLEXIBLE SUPPLIES ON LAUNDRY TUB, LAV, TOILET SOUTHEAST ELEVATION | 1701 W 79TH ST | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMIT FOR LAUNDRY TUB SOUTHEAST ELEVATION 1ST FLOOR | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | PROVIDE OPEN FRONT TOILET SEAT SOUTHEAST ELEVATION 1ST FLOOR | 1701 W 79TH ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | PVC P-TRAP FOR LAUNDRY TUB SOUTHEAST ELEVATION 1ST FLOOR | 1701 W 79TH ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL ENTRY DOORS ON EXTERIOR OF RESIDENTIAL AND COMMERCIAL EXIT DOORS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SYSTEM III | INSTALL EMERGENCY LIGHTING SYSTEM WITH BATTERY BACK UP AND CHICAGO APPROVED FIXTURES | 1701 W 79TH ST | COMPLAINT | FAILED | View |
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS | 1701 W 79TH ST | COMPLAINT | FAILED | View | |
OBTAIN PERMIT BEFORE SIGN WORK | FOR INSTALLATION OF VINYL BANNER 3'X 10' NORTH ELEVATION SIGN READS" JORDAN FOR MART" 13-20-550, 13-20-520 | 1701 W 79TH ST | COMPLAINT | FAILED | View |
OBTAIN PERMIT BEFORE SIGN WORK | FOR INSTALLATION OF VINYL BANNER 3'X 4' NORTHEAST ELEVATION SIGN READS" JORDAN FOR MART" 13-20-550, 13-20-520 | 1701 W 79TH ST | COMPLAINT | FAILED | View |
OBTAIN PERMIT BEFORE SIGN WORK | FOR INSTALLATION OF VINYL BANNER 3'X 10' EAST ELEVATION SIGN READS" JORDAN FOR MART" 13-20-550, 13-20-520 | 1701 W 79TH ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | BOARDED WINDOWS AT WEST ELEVATION (14X3-303.13) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
MIXED OCCUPANCY SEPARATION | 1 HR FIRE SEPARATION REQUIRED WITHIN ELECTRICAL PANEL ROOM LOCATED WITHIN THE REAR OF STORE CURRENTLY CEILING MISSING SECTION OF DRYWALL/PLASTER (14B-5-508) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
BUILDING IN DISREPAIR | SOUTH ELEVATION AT 1701 STOREFRONT LOCATION WINDOW UNIT MOUNTED FROM WINDOW WITH POOR MEANS OF SUPPORT (DANGEROUS AND HAZARDOUS) 14A-3-315 | 1701 W 79TH ST | COMPLAINT | FAILED | View |
REPAIR COPING | MISSING COPING TILE AT THE EAST AND NORTH ELEVATION REPAIRS REQUIRED (14X-3-303.6) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPERLY | LAVATORY BASIN IS INSTALLED TOO CLOSE TO TOILET LAVATORY IS INSTALLED IN A MANNER THAT THE BASIN OF LAVATORY IS DIRECTLY ABOVE TANK OF TOILET | 1701 W 79TH ST | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | OPEN BOXES BEHIND CEILING LIGHT FIXTURE LOCATIONS 1ST FLOOR STORE 1701 CLOSE OPEN BOXES WHERE REQUIRED | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | UNAPPROVED FLEXIBLE METAL CONDUIT AT COUNTER AREA 1ST FLOOR STORE 1701 REMOVE WHERE REQUIRED (14E-3-348.10) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES AT LOWER FRONT WINDOW AREA, AT WINDOW AREA AND WHERE REQUIRED TO PREVENT EXTENSION CORD USAGE 1ST FLOOR STORE 1701 DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PROVIDE REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRE DEVICE AND EQUIPMENT AT 1ST FLOOR STORE 1701, WEST EXTERIOR STAIR AREA AND WHERE REQUIRED THROUGHOUT PREMISES MISCELLANEOUS ELECTRIC STORE NEW LIGHTING WEST EXTERIOR STAIRS NO/INSUFFICIENT INSPECTIONS PREVIOUS PERMITS (14A-5-505.2) | 1701 W 79TH ST | COMPLAINT | FAILED | View | |
INSTALL COVERS | PANEL USED AS JUNCTION BOX HAS BROKEN COVER FRONT COUNTER AREA 1ST FLOOR STORE 1701 | 1701 W 79TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ALLOW FULL INTERIOR INSPECTION OF THE ENTIRE PROPERTY (ENTRY ONLY 1701 W 79) AND EXTERIOR INSPECTION CONDUCTED AT PROPERTY ONLY (14A-1-104.7) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE PERMIT TO CORRECT VIOLATIONS AND FOR THE INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRE DEVICES AND EQUIPMENT AT 1ST FLOOR STORE 1701, WEST EXTERIOR STAIR AREA AND WHERE REQUIRED THROUGHOUT PREMISES MISCELLANEOUS ELECTRIC STORE NEW LIGHTING WEST EXTERIOR STAIRS NO/ INSUFFICIENT INSPECTIONS PREVIOUS PERMITS (14A-4-404.6) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | MISSING KO FILLERS VARIOUS 1ST FLOOR STORE 1701 INSTALL WHERE REQUIRED DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | CENTER BATTERY LIGHTS NOT OPERABLE 1ST FLOOR STORE ENSURE EXISTING EMERGENCY LIGHTING AND EXIT SIGN SYSTEM WHERE REQUIRED THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | UNAPPROVED ROUND BOWL TOILET SHOULD BE ELONGATED TYPE WITH ELONGATED OPEN FRONT SEAT | 1701 W 79TH ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | OPEN WIRING PROTRUDING FROM FITTING AT FRONT EXTERIOR REMOVE OPEN WIRING WHERE REQUIRED THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | ENGAGE LICENSED AND BONED PLUMBING CONTRACTOR TO INSTALL PLUMBING | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SECURE RACEWAY | LOSE RACEWAYS AT FRONT COUNTER AREA COUNTER PANEL/JUNCTION BOX 1ST FLOOR STORE 1701 SECURE RACEWAYS IN APPROVED MANNER WHERE REQUIRED THROUGHOUT PREMISES | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PANEL SCHEDULES | INSUFFICIENT PANEL SCHEDULES 1ST FLOOR STORE 1701 INSTALL WHERE REQUIRED | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | UNAPPROVED PVC TUBULAR WASTE PIPING AT BATHROOM LAVATORY | 1701 W 79TH ST | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | SERVICE CONDUCTORS VISIBLY DETERIORATED AT REAR EXTERIOR SERVICE HEAD SERVICE HEAD DAMAGED OVERHEAD SERVICE SPLICES ARE VISIBLY DETERIORATING LOW VOLTAGE WIRES IN CONTACT WITH OVER HEAD SERVICE WIRES ENSURE SERVICE(S) IN APPROVED CONDITION DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND BOX | UNSUPPORTED BOX FRONT COUNTER AREA 1ST FLOOR STORE 1701 SECURE BOXES WHERE REQUIRED THROUGHOUT PREMISES | 1701 W 79TH ST | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | OBTAIN PERMIT BEFORE CONSTRUCTING ALTERING OR USING PLUMBING SYSTEM | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PROVIDE ACCESS TO INSPECT CONDITION OF ELECTRICAL SERVICE EQUIPMENT (14A-5-505.2) | 1701 W 79TH ST | COMPLAINT | FAILED | View | |
DEFECTIVE OUTLETS | LOOSE RECEPTACLES WITH MISSING TRIM PLATES AT FRONT COUNTER 1ST FLOOR STORE 1701 REPAIR DEVICES AND INSTALL TRIM PLATES WHERE REQUIRED THROUGHOUT PREMISES | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PROVIDE | NO MIXING VALVE AT EMPLOYEE BATHROOM (18-29-607) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | RACEWAY PULLED AWAY FROM BOX AT WEST EXTERIOR STAIRS ENSURE GROUND CONTINUITY WHERE REQUIRED THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | REMOVE EXPOSED WIRING TO EXHAUST FAN IN BATHROOM | 1701 W 79TH ST | COMPLAINT | FAILED | View |
18-27-240.24(D)(E) RELOCATE PANEL AWAY FROM SINK IN CLOSET | 1701 W 79TH ST | COMPLAINT | FAILED | View | |
UNAPPROVED CORDS | REMOVE ALL EXTENSION CORDS THROUGHOUT STORE. INSTALL ADDITIONAL OUTLETS TO AVOID USE OF CORDS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PROVIDE | NO MIXING VALVE AT EMPLOYEE BATHROOM (18-29-607) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
INSTALL COVERS | 7901 OPEN BOXES FIRST FLOOR CEILING CLOSE WHERE REQUIRED DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | 7901 ADD RECEPTACLES AT FRONT WINDOW AREAS AND WHERE REQUIRED TO PREVENT USE OF CORDS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | 1 HOUR FIRE SEPARATION ROOM REQUIRED FOR FURNACE AND ALL MECHANICALS (14B-5-509) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | 7901-05 NO EMERGENCY LIGHTING SYSTEM AT NORTH BASEMENT INSTALL WHERE REQUIRED DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
1HR ENCL FLR TO FLR SHAFT/DUCT | ALL PIPE PENETRATIONS THROUGHOUT BASEMENT AREAS SHOULD BE SEALED WITH FIRE RESISTANT MATERIAL CURRENTLY MISSING SECTIONS OF MASONRY MULTIPLE LOCATIONS THROUGHOUT (14X-5-502.3) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | 7901-05 OPEN AIR SPLICES BETWEEN FLEXIBLE METAL CONDUIT NORTH BASEMENT ENSURE GROUND CONTINUITY WHERE REQUIRED NO EQUIPMENT GROUND VISIBLE AT REFRIGERATION DISCONNECT BASEMENT DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | 7901-05 PROVIDE ACCESS TO INSPECT CONDITION OF ELECTRICAL SERVICE EQUIPMENT (14A-5-505.2) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | 7901-05 INSTALL OPERABLE ILLUMINATION AT ALL EXTERIOR ENTRIES, STAIRS, BASEMENT AREAS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
INSTALL COVERS | 7901-05 OPEN BOXES THROUGHOUT NORTH BASEMENT INSTALL COVERS WHERE REQUIRED DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | 7901-05 SERVICE RACEWAY AND SERVICE CABLES DETERIORATED SERVICE RACEWAY HAS HEAD BROKEN/MISSING ENSURE SERVICE IN APPROVED CONDITION DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | 7901-05 DAMAGED CORDS NORTH BASEMENT REMOVE WHERE REQUIRED DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | UNAPPROVED PVC TUBULAR WASTE PIPING AT BATHROOM LAVATORY | 1701 W 79TH ST | COMPLAINT | FAILED | View |
DETERIORATED CONDUCTORS | 7901-05 DETERIORATED CLOTH WIRING VISIBLE AT NORTH BASEMENT REPLACE WHERE REQUIRED | 1701 W 79TH ST | COMPLAINT | FAILED | View |
7901-05 UNSUPPORTED LOW VOLTAGE CABLES WEST AND REAR EXTERIOR SECURE WHERE REQUIRED (14E-8-800.24) | 1701 W 79TH ST | COMPLAINT | FAILED | View | |
PROPER SIZE OCP | 7901-05 INSTALL GFCI PROTECTION NORTH BASEMENT, KITCHEN,BATH,EXTERIOR | 1701 W 79TH ST | COMPLAINT | FAILED | View |
STOP LEAKING WATER | LEAKING WATER THROUGHOUT BASEMENT | 1701 W 79TH ST | COMPLAINT | FAILED | View |
7901-05 EXTERIOR LIGHT FIXTURES,BOXES,FITTINGS, RACEWAYS MUST BE SUITABLE FOR WET LOCATIONS 14E-1-110.3) | 1701 W 79TH ST | COMPLAINT | FAILED | View | |
REMOVE STAGNANT WATER BSMT | STAGNANT WATER THROUGHOUT BASEMENT FLOOR DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | 7901-05 OPEN WIRE NORTH BASEMENT AND FRONT EXTERIOR REMOVE WHERE REQUIRED DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | NOXIOUS ODORS THROUGHOUT 1ST FLOOR COMMERCIAL SPACE (14X-6-603.4) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
ARMORED CABLE | 7901-05 EXCESSIVE UNAPPROVED, UNSUPPORTED BX AT NORTH BASEMENT REMOVE WHERE REQUIRED | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND BOX | 7901-05 UNSUPPORTED BOXES NORTH BASEMENT AND WEST EXTERIOR SECURE WHERE REQUIRED | 1701 W 79TH ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | 7901 MISSING EQUIPMENT GROUND REFRIGERATION DISCONNECT BASEMENT DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | 7901-05 NUMEROUS MISSING KO FILLERS NORTH BASEMENT INSTALL WHERE REQUIRED DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SECURE RACEWAY | 7901-05 UNSUPPORTED BOXES NORTH BASEMENT AND WEST EXTERIOR SECURE WHERE REQUIRED | 1701 W 79TH ST | COMPLAINT | FAILED | View |
7901-05 OBTAIN PERMIT TO CORRECT VIOLATIONS AND FOR THE INSTALLATION OF ELECTRICAL CONDUIT,BOXES,WIRE,DEVICES AND EQUIPMENT MISCELLANEOUS WORK THROUGHOUT NORTH BASEMENT (14A-4-404.6) | 1701 W 79TH ST | COMPLAINT | FAILED | View | |
PROVIDE OPEN FRONT TOILET SEAT | UNAPPROVED ROUND BOWL TOILET. TOILET SHOULD BE ELONGATED TYPE WITH ELONGATED OPEN FRONT SEAT | 1701 W 79TH ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | MISSING FIRE SEPARATION OVER BASEMENT AREA CEILINGS THROUGHOUT CURRENTLY 1/2" DRYWALL USED AS FIRE SEPARATION AT CEILINGS THROUGHOUT (14B-6-605.4) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | CEILINGS WITHIN 1ST FLOOR COMMERCIAL SPACE WATER DAMAGED (14X-3-304.3) FURNACE SUSPENDED OVER STAIRWAY LEADING TO BASEMENT IN DANGEROUS AND HAZARDOUS POSITION 1 | 1701 W 79TH ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT ENTRY DOOR OBSTRUCTED AND NOT ABLE TO OPEN TO A FULL 90 DEGREES DUE TO CLOSER NOT PROPERLY INSTALLED REAR DOOR MARKED EXIT UNABLE TO OPEN AND REQUIRES KEY TO ENTER DUE TO PADLOCK AND SCISSOR GATE (14X-3-304.3) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRS LEADING TO BASEMENT AREAS (DANGEROUS AND HAZARDOUS) LOOSE RAILS (2) HORIZONTAL SPINDLES (3) LOOSE TREADS REPAIRS REQUIRED (14X-3-304.4) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
INTERIOR FINISH FIRERESISTANCE | BATHROOM THROUGHOUT 1ST FLOOR CEILING IMPROPER MATERIAL USED (14B-8-803.1.1) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHERS REQUIRED THROUGHOUT 1ST FLOOR COMMERCIAL SPACE (14X-5-504.5) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | 90 MINUTE DOOR REQUIRED FOR FURANCE AND ALL MECHANICAL (14B-7-716) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
OPEN | NO FLOOR DRAIN AT BATHROOM (18-29-412.4.3) | 1701 W 79TH ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | BROKEN SUSPENDED CAST IRON HUB AND LEAKING ILLEGAL CLEANOUT PLUG TO SUSPENDED CAST IRON CLEANOUT AT BASEMENT DANGEROUS AND HAZARDOUS | 1701 W 79TH ST | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING | 1701 W 79TH ST | COMPLAINT | FAILED | View |
PRV SLUDGE DRAIN FRO GRAV TANK | OBTAIN PLUMBING PERMIT BEFORE CONSTRUCTING ALTERING OR USING PLUMBING SYSTEM | 1701 W 79TH ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | 7901 OBTAIN PERMIT TO CORRECT VIOLATIONS (14A-4-404.6) | 1701 W 79TH ST | COMPLAINT | FAILED | View |