Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
UNAPPROVED HEATING DEVICE | BASEMENT APARTMENT- USING COOKING STOVE AS HEATING DEVICE. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT APARTMENT- MISSING CARBON MONOXIDE DETECTOR. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | BASEMENT APARTMENT- FRONT ROOM 63, BEDROOM 61. HEATING SYSTEM IS ON AT TIME OF INSPECTION- HEAT IS INSUFFICIENT. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | SOUTH FRONT ENTRANCE GATE - DOUBLE KEY LOCKED.NORTH FRONT ENTRANCE GATE - DOUBLE KEY LOCK. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ENTRANCE DOOR/ BOTTOM OF FRAME - ROTTED. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS - MISSING SCREENS. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2-STORY PARTIALLY ENCLOSED WOOD PORCH/ DECKS - EXCESSIVE SLOPES. RAILING - ONLY 40 INCHES HIGH AND ONLY NAILED TO COLUMNS.STAIR RAILINGS - LADDER TYPE WITH 6 INCHES BETWEEN MEMBERS AND ONLY NAILED TO POSTS.PLANS AND PERMIT REQUIRED TO REPAIR PORCH. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR 20 FEET BY 30 FEET CAR PORT - BUILT FROM LOT LINE TO LOT LINE WITHOUT PLANS OR PERMIT.SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT #100259083 ISSUED ON 9/23/08 FOR REMOVAL OF NON - CODE CONFORMING CAR PORT. EXPIRED WITHOUT ANY ACTIVITY IN THE MATTER. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 2821 N SPRINGFIELD AVE | PERMIT | PASSED | View | |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED . POSTED PAPER SIGN NOT LEGIBLE OR VISIBLE FROM STREET . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED | PERMIT REQUIRED FOR FRONT YARD SIX FOOT HIGH IRON YARD FENCE AND GATES AND REAR YARD SIX FOOT HIGH WOOD YARD FENCES . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT IRON PORCH , UPRIGHTS , STINGERS AND STAIR PANS SEVERELY RUSTED , DETERIORATED WITH FLAKING PAINT . ALL GUARDRAILS IMPROPER DESIGN WITH HORIZONTAL BARS ( LADDER EFFECT ) AND SPACED OVER FOUR INCH MAXIMUM . PLANS AND PERMITS REQUIRED . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR TWO STORY WOOD PORCH , STAIRWAYS AND DECKS LEANING OUTWARDS SEVERELY , HAZARD TO TENANTS AND OCCUPANTS . PLANS AND PERMITS REQUIRED . UNKNOWN FOUNDATION STATUS WITH UPRIGHTS SET IN CONCRETE BLOCKS . UPRIGHT ROTTED , BUTT STACKED . BEAMS OVERSPANNED AND SAGGING AT COLUMN CONNECTIONS, WITH SCABBED CONNECTIONS . STAIRWAYS SAGGING AND LEANING . FLOOR JOIST OVERSPANNED AND UNDERSIZED . GUARDRAILS OVERSPANNED . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | IMMEDIATELY REMOVE OVERSIZED WOOD CARPORT ( BUILT LOT LINE TO LOT LINE , APPROXIMATE SIZED 24 BY 30 FEET ) INSTALLED IN REAR OF LOT WITHOUT PLANS OR PERMITS AND RESTORE THE PROPERTY TO THE ORIGINAL STATE . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | BRICKS PILED NEXT TO SOUTH FENCE BY PORCH , RAT HARBORAGE . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | STOP ALL WORK / CONSTRUCTION PERFORMED WITHOUT A PERMIT PER SECTION 13-12-080, 13-32-035 | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | ACQUIRE PERMIT FOR CARPORT BUILT AT REAR OF PROPERTY THE STRUCTURE IS WOOD FRAMED WITH DRYVIT STUCCO IT SPANS FROM LOT LINE TO LOT LINE ABOUT 20'-0" DEEP AND 14'HT. | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | FRONT , REAR AND SIDE YARDS , LANDSCAPE DEBRIS . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES ( INCLUDING PLUMBING AND ELECTRICAL ) INSTALLED IN THE BASEMENT WITHOUT A PERMIT . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD AND UNDER REAR PORCH , JUNK , DEBRIS , RAT HARBORAGE . | 2821 N SPRINGFIELD AVE | COMPLAINT | FAILED | View |
OPEN | 2821 N SPRINGFIELD AVE | PERMIT | PASSED | View |