The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | 1ST 65 DEGREES, LIVING ROOM | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
ADD BRANCH CIRCUITS | THROUGHOUT FIRST FLOOR APARTMENT 18-27-210.11 | 6938 S PAULINA ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS GRADE TO 2ND FLOOR - NO FOOTINGS, STRINGERS OVERCUT, NO JOIST HANGERS, NO LEDGER BOLTS, GUARDRAILS UNDER 42" INCHES, TREADS NOT 10" INCHES, STRINGERS NOT BOLTED, LOOSE NAILS, REAR STAIRS GRADE TO 1SAT NO JOIST HANGERS NO LEDGER BOLTS, NO HAND RAIL AT BASEMENT STAIRS. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS NEEDED FOR STAIRS GRADE TO 2ND, SHOW PLANS FOR EXTENSIVE DORMER WORK. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO WHOLE BUILDING AND REAR GARAGE. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | OPEN MORTAR JOINTS SOUTH WALL. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REPAIR SERVICEWALK- SOUTH AND WEST ELEVATION/ BROKEN AND UNEVEN CONCRETE- TRIPPING HAZARD. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRSYSTEM- SOUTHEAST ELEVATION/ IRON 2 STORY STAIRYSTEM. 4X4 COLUMNS ERECTED ON TOP OF SEVICEWALK NO VISIBLE FOUNDATION FOOTING. NO FOUNDATION FOOTING AND NO PERMIT OBTAINED. OBTAIN PERMIT FOR 2 STORY IRON STAIRSYSTEM AND ARRANGE A FOOTING INSPECTION WITH PERMIT ON PREMISES. REAR GRADE TO BASEMENT STAIRSYSTEM- GUARDRAIL MISSING | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FOUNDATION WALL- REAR FOUNDATION WALL- SPALLING BRICKS, PEELING PAINT AND WASHED OUT MORTAR | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLAN AND OBTAIN NEW PERMIT. SEE PERMIT #100216468 ISSUED 12/14/2007. REAR PORCH NOT FINALIZED. SUBMIT PLAN AND OBTAIN PERMIT FOR 2ND FLOOR ADDITION. NO PERMIT OBTAINED. PLAN AND PERMIT NOW REQUIRED. SUBMIT PLAN AND OBTAIN PERMIT FOR GARAGE ALTERATION. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
CONTRARY TO ORIGINAL PLAN | GARAGE ORIGINALLY 2 CAR GARAGE CONVERTED INTO DWELLING UNIT. DISCONTINUE USE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL NON LOAD BEARING PARTITION INSTALLED IN GARAGE WITHOUT A PERMIT | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING/ REFUSED ENTRY BY 2ND FLOOR TENANT. UNVERIFIED DETECTORS AND OCCUPANCY. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR 2ND FLOOR/ SIDING LOOSE AND DETACHED | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH- COLUMNS ERECTED ON TOP OF CONCRETE BASE AND OR ON CONCRETE SLAB; FOUNDATION FOOTING STATUS UNKNOWN. 6X6 COLUMN OUT OF PLUMB, NOT CENTERED ON BASES. 6X6 BEAM SUPPORTING DECK JOINT, NOT RUNNING FULL LENGTH OF DECK, 6X6 COLUMN NOT SUPPORTING BEAM; WEDGED UNDERNEATH (IMPROPER) 6X6 COLUMN 2X10 SWAY BRACES AT BOTTOM OF COLUMNS. SCAB WOOD USED BETWEEN COLUMN AND EXTERIOR WALL. DECK JOIST MISSING JOIST HANGERS. ALL COMPONENTS- TOE NAILED | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | 18-27-210.25 PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREA AND GARAGE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
13-12-360 PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES, WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT 2ND FLOOR DOORMED ADDITION AND GARAGE AREAS | 6938 S PAULINA ST | COMPLAINT | FAILED | View | |
18-27-110.3 PROVIDE INTERIOR INSPECTION TO VERIFY LOCATION AND CONDITION OF ELECTRICAL PANEL | 6938 S PAULINA ST | COMPLAINT | FAILED | View | |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES, WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT 2ND FLOOR DORMER AREA AND GARAGE AREA | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
DEMO DEBRIS | ACCUMULATION OF CONSTRUCTION DEBRIS UNDERNEATH REAR PORCH | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | 2ND FLOOR THROUGHOUT DEFLECTS WHEN WALKING | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | OBTAIN A STRUCTURAL ENGINEER'S REPORT ON 2ND FLOOR LOAD | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR SCREENS | TORN SCREEN ON 2ND FLOOR WINDOWS | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | DOOR TO BEDROOM, 2ND FLOOR, ONLY 6 FOOT 4 INCHES | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | BROKEN FLOOR TILES ON 1ST FLOOR | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO WORKING SMOKE DETECTORS ON THE 1ST FLOOR- A DANGEROUS AND HAZARDOUS CONDITION | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO WORKING CARBON MONOXIDE DETECTORS ON 1ST FLOOR - A DANGEROUS AND HAZARDOUS CONDITION | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | REMOVE LOCK FROM REAR SECURITY GATE AND REMOVE SMOKER FROM REAR FIRST FLOOR PORCH, WHICH IS AGAINST REAR DOOR - A DANGEROUS AND HAZARDOUS CONDITION | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | OBTAIN STRUCTURAL ENGINEER'S REPORT ON THE FIRST FLOOR STRUCTURE, WHICH HAS DEFLECTION WHERE REAR ORIGINAL STAIRS WERE REMOVED AND IMPROPER CONNECTIONS DONE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | FLOOR HAS DEFLECTED WITH NO JOIST HANGERS OBSERVED, AND DEFLECTS UNDER LOAD- A DANGEROUS AND HAZARDOUS CONDITION | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | STEEL BEAMS IN THE BASEMENT RUSTING, REPAIR OR REPLACE, PURSUANT TO 130-148-010B OF THE CODE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
INSECTS | FIRST FLOOR FLEA INFESTED | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | STAIR SYSTEM LEADING TO BASEMENT AT THE REAR HAS NO HANDRAIL OR GUARDRAIL | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | MISSING PLASTER AND LATH THROUGHOUT BASEMENT AREA | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | NO SEPARATION AROUND WATER HEATER IN THE BASEMENT | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | BASEMENT-SINK STACK-REMOVE THREE 2" PVC PIPES AT THE BASE OF STACK AND SEAL OPENINGS | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | ROD SINK LINE OUT TO GREASE TRAP TO CLEAR BLOCKAGE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REMV SADDLE HUB CONNECTIONS | REMOVE SADDLE CONNECTION AT BASE OF 4" SOIL STACK | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
CLEAN CATCH BASIN | CLEAN CATCH BASIN | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
PRV WATER AT PLUMBING FIXTURE | REPLENISH FLOOR DRAIN TRAP SEAL | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
PRV CNTRL VALVE WATER SUPPLY | REPLACE VALVES ON WATER HEATERS WITH FULL OPEN VALVES, SWEAT JOINTS | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
PRV DISCHARGE PIPE FROM PRV | REMOVE PVC PIPE AND FITTINGS USED ON WATER HEATER RELIEF VALVES AND RE-PIPE WITH METAL PIPE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | REMOVE ALL PLUMBING INSTALLED WITHOUT A PERMIT IN THE SECOND FLOOR APARTMENT AND COACH HOUSE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | REMOVE RAW SEWAGE FROM BASEMENT FLOOR, AND CLEAN THOROUGHLY | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PERMIT FOR PLUMBING WORK | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR KITCHEN COUNTERTOP AREAS, BATHROOM AND LAUNDRY AREA OF BASEMENT, 1ST AND 2ND FLOOR AREAS, PURSUANT TO 18-27-210.8, 18-27-570.8 OF THE CODE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
PROVIDE WEATHERPROOF BOXED LIGHT FITTINGS AND APPROVED RACEWAYS FOR REAR PORCH LIGHTS, PURSUANT TO 18-27-110.11 OF THE CODE | 6938 S PAULINA ST | COMPLAINT | FAILED | View | |
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT 1ST AND 2ND FLOOR UNITS IN FRONT BUILDING AND IN REAR BUILDING, PURSUANT TO 13-12-380 OF THE CODE | 6938 S PAULINA ST | COMPLAINT | FAILED | View | |
SECURE RACEWAY | PROPERLY SUPPORT ALL CONDUIT RUNS THROUGHOUT ALL BASEMENT AREAS | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
GROUND EQUIPMENT | PROVIDE A WATER MAIN GROUND CONDUCTOR TO WITHIN 5' OF WATER METER OR VALVE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | BOND ELECTRICAL PANELS TO CONNECT ALL OF THE METALLIC ENCLOSURES THAT ARE LIKELY TO BECOME ENERGIZED SO AS TO ESTABLISH AN EFFECT PATH FOR FAULT CURRENT, PURSUANT TO 18-27-250.2 OF THE CODE | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
MOGUL TYPE L.B. REQUIRED ON SUPPLY SIDE OF SERVICE, PURSUANT TO 18-27-370.16 OF THE CODE | 6938 S PAULINA ST | COMPLAINT | FAILED | View | |
INSTALL ILLUMINATION | PROVIDE ILLUMINATION THROUGHOUT ALL BASEMENT AREAS OF FRONT BUILDING | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES THROUGHOUT BASEMENT AREAS | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES, WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED WITHOUT PLANS AND PERMITS IN 1ST AND 2ND FLOOR OF FRONT BUILDING, AND THROUGHOUT REAR BUILDING STRUCTURE WITHOUT PLANS AND PERMITS, AND NEW METER BOX PANELS FOR FRONT BUILDING WITHOUT PERMITS | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | THE WALLS AND CEILINGS ARE WATER DAMAGED | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | THE GAS SERVICE HAS BEEN SHUT OFF AND NO HEAT IS PROVIDED | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | THE COLD WATER PIPES ARE FROZEN AND BUSTED AND NO COLD WATER IS PROVIDED | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR BARE WIRES TO KITCHEN LIGHT BOX IN FIRST FLOOR UNIT- DANGEROUS AND HAZARDOUS CONDITION | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
ARMORED CABLE | REMOVE ALL DEFECTIVE ARMORED CABLE THROUGHOUT FIRST FLOOR AREA | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | BROKEN FLOOR TILES ON 2ND FLOOR | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
CHIMNEY | OPEN MORTAR JOINTS AT NORTH CHIMNEY. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | HIGH WEEDS ALL ELEVATIONS. | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | SUPPLY ADEQUATE HOT WATER WITH MINIMUM TEMPERATURE OF 120 DEGREES F PURSUANT | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REINSTATE UTILITY SERVICE | GAS SHUT OFF TO SECOND FLOOR AND USING A PROPANE HEATER FOR HOT WATER AND HEAT IN THE BATHROOM - A DANGEROUS AND HAZARDOUS CONDITION | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | FRONT AND REAR DOORS, FIRST FLOOR, HAVE PILLOWS AND TOWELS AT DOORWAYS TO STOP DRAFTS - A DANGEROUS AND HAZARDOUS CONDITION | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | FIRST FLOOR, GARBAGE AND CLOTHES THROUGHOUT | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR | 6938 S PAULINA ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | THE GAS SERVICE HAS BEEN SHUT OFF AND NO HEAT IS PROVIDED | 6938 S PAULINA ST | COMPLAINT | FAILED | View |