Chicago Building Violations Data: 38 Violations
Violation Inspector Comments Address Category Status View
REMOVE AND REPLACE***** REPLACE MISSING SIGN FACE IN THE BUSINESS SIGN STRUCTURE 13-20-530 7131 S STATE ST COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT D&H REMOVE DEFECTIVE METER SOCKET (CLUTTER AND OBSTRUCTED DEBRIS IN WAY) 7131 S STATE ST COMPLAINT PASSED View
LISTED FOR USE TEMP & LOCATION ELECTRICAL EQUIPMENT SHALL BE LISTED FOR USE , TEMPERATURE AND LOCATION EXTERIOR OF BUILDING 7131 S STATE ST COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS BOARDED WINDOWS LOCATED AT THE WEST ELEVATION 7131 S STATE ST COMPLAINT PASSED View
WALL & CEILING NO HOLES/CRACKS WATER DAMAGED CEILING TILES THROUGHOUT PROPERTY 7131 S STATE ST COMPLAINT PASSED View
HEATING PLANT ENCLOSURE 1HOUR ENCLOSURE REQUIRED FOR FURNACE LOCATED AT REAR OF PROPERTY. 7131 S STATE ST COMPLAINT PASSED View
INTERIOR FINISH FIRERESISTANCE REAR OF PROPERTY STORAGE ROOM FINISHED WITH WOOD PANELING REMOVE AND REPLACE WITH PROPER FIRE RESISTANT MATERIAL 7131 S STATE ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMITS REQUIRED FOR STORAGE SPACES CONSTRUCTED AT REAR OF PROPERTY, ALSO PLANS AND PERMITS REQUIRED FOR REAR OVERHANG CONSTRUCTED WITHOUT PLANS OR PERMITS. 7131 S STATE ST COMPLAINT PASSED View
STRUCTURAL MEMBER, PIER BLOCK REPAIR STRUCTURAL MEMBER, CURRENTLY STEEL COLUMN REMOVED AT REAR OF PROPERTY AT COOLER AREA AT SOUTH/EAST SECTION OF PROPERTY AND REPLACED WITH 6X6 WOOD COLUMN. 7131 S STATE ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR THROUGHOUT PROPERTY. 7131 S STATE ST COMPLAINT PASSED View
CARB MONOX DETECT IN ASSEMBLY INSTALL WORKING CARBON MONOXIDE DETECTORS THROUGHOUT PROPERTY 7131 S STATE ST COMPLAINT PASSED View
UNAPPROVED HEATING DEVICE STOP USING SPACE HEAT FOR 2ND MEANS OF HEAT 7131 S STATE ST COMPLAINT PASSED View
OBTN PERMIT FOR PLUMBING WORK 7131 S STATE ST COMPLAINT PASSED View
LICENSED BONDED PLMBG CONTRCTR 7131 S STATE ST COMPLAINT PASSED View
REPLACE DEFECTIVE PLBG FIXTURE NO COMMERICAL ELONGATED TOILET IS INSTALLED IN COMMERICAL PROPERTY PER CITY OF CHICAGO CODE 7131 S STATE ST COMPLAINT PASSED View
PROVIDE OPEN FRONT TOILET SEAT NO OPEN FRONT TOILET SEAT IS INSTALLED ON TOILETS IN COMMERICAL LOCATION 7131 S STATE ST COMPLAINT PASSED View
SOIL/WASTE,VENT PIPE MATRL PVC IS INSTALLED FOR DRAIN, WASTE, AND VENT PIPING TROUGHOUT COMMERICAL LOCATION D&H 7131 S STATE ST COMPLAINT PASSED View
PRV FLOOR DRAIN WITH METAL STR FLOOR DRAINS THROUGHOUT LOCATIONS DOES NOT HAVE METALIC STAINER COVERS 7131 S STATE ST COMPLAINT PASSED View
SOIL/WASTE,VENT PIPE MATRL LAVATORIES AND HAND SINKS BEHIND MEAT COUNTER HAS ACCORDIAN WASTE PIPING FOR DRAIN P-TRAP 7131 S STATE ST COMPLAINT PASSED View
PRV BALLCOCK,VB,OR AIR GAP NO VACCUM BREAKER ON MOP SINK FAUCET BEHIND MEAT COUNTER 7131 S STATE ST COMPLAINT PASSED View
PRV BALLCOCK,VB,OR AIR GAP NO VACUUM BREAKER ON HOSE CONNECTORS ATTACHED TO POTABLE WATER SYSTEM BEHIND MEAT COUNTER AT 3 COMPARTMENT SINK 7131 S STATE ST COMPLAINT PASSED View
PRV GREASE INTCPT OR CTH BASIN GREESE INTERCEPTOR AT 3 COMPARTMENT SINK IS NOT OF CORRECT SIZE AND IS NOT TIGHTLY SEALED 7131 S STATE ST COMPLAINT PASSED View
PRV DISCHARGE PIPE FROM PRV PVC PIPE IS INSTALLED ON TEMPETURE AND PRESSURE RELIEF VALVE ON HOT WATER TANK 7131 S STATE ST COMPLAINT PASSED View
REPLACE DEFECTIVE WASTE PIPING HAND SINK BEHIND COUNTER IS NOT CONNECTED TO SEWER WASTE PIPE. THIS IS CREATING AN OPEN SEWER 7131 S STATE ST COMPLAINT PASSED View
RMV PLBFIX INSTALLD W/0 PERMIT BATHROOM IN REAR OF STORE BY BUSINESS OFFICE WITH SHOWER IS NOT OF ORGINAL STORE AND NEEDS PLANS AND PERMITS AND INSPECTION 7131 S STATE ST COMPLAINT PASSED View
REMOVE MINI-BREAKERS D&H REMOVE UNAUTHORIZED MINI BREAKERS 7131 S STATE ST COMPLAINT PASSED View
PROPER SIZE GRD ELECTRODE COND D&H INSTALL PROPER SIZE GROUNDING CONDUCTOR (NOT RECOGNIZED) 7131 S STATE ST COMPLAINT PASSED View
SUPPLEMENTAL GROUND D&H INSTALL REQUIRED SUPPLEMENTAL GROUNDING CONDUCTOR 7131 S STATE ST COMPLAINT PASSED View
WORKING SPACE D&H PROVIDE AT LEAST 3FEET CLEAR SPACE AROUND ELECTRICAL PANEL AND RELATED EQUIPMENT 7131 S STATE ST COMPLAINT PASSED View
ADD RECEPTACLES D&H INSTALL ADDITIONAL RECEPTACLE OUTLETS TO EASE EXTENSION CORD USAGE 7131 S STATE ST COMPLAINT PASSED View
CONTINUITY OF RACEWAYS D&H PROVIDE GROUND CONTINUITY FOR ELECTRICAL CABLE, RACEWAYS AND ENCLOSURES INSIDE AND OUTSIDE BUILDING 7131 S STATE ST COMPLAINT PASSED View
EXPOSED WIRING FIXTURES D&H REMOVE EXPOSED WIRING AT LIGHT FIXTURES THROUGH-OUT INTERIOR OF BUILDING 7131 S STATE ST COMPLAINT PASSED View
SYSTEM II D&H INSTALL EXIT AND EMERGENCY LIGHTING SYSTEM AND RELATED EQUIPMENT TO WORKING CONDITION. INSTALL MIN (2) BATTERY PACK EM LIGHTS ON GENERAL FLOOR. 7131 S STATE ST COMPLAINT PASSED View
PANEL SCHEDULES PROVIDE DETAIL AND LEGIBLE PANEL SCHEDULES 7131 S STATE ST COMPLAINT PASSED View
CLOSE BOX OPENINGS D&H CLOSE UNUSED OPENINGSIN ELECTRICAL BOX OR CABINET 7131 S STATE ST COMPLAINT PASSED View
CORD WIRED EQUIPMENT D&H REMOVE UNAPPROVED CORD SUPPLY TO PERMANENTLY INSTALLED APPLIANCE 7131 S STATE ST COMPLAINT PASSED View
SUPPORT OUTLET AND BOX D&H FASTEN AND SUPPORT CONDUIT THROUGH-OUT BUILDING INTERIOR AND EXTERIOR 7131 S STATE ST COMPLAINT PASSED View
OBTAIN ELECTRICAL PERMIT AND LICENSED ELECTRICIAN TO PERFORM WORK 7131 S STATE ST COMPLAINT PASSED View