Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN WINDOW | ALL ELEVATION WINDOW FRAME ROTTED/LOOSE | 3006 W WALNUT ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | FOR SOUTH ELEVATION LOOSE/MISSING SHINGLES | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST FLOOR FRONT WINDOW BROKEN PANE | 3006 W WALNUT ST | COMPLAINT | CLOSED | View |
DEFECTIVE OUTLETS | #2 FLOOR WALL OUTLET LOOSE HANGING | 3006 W WALNUT ST | COMPLAINT | CLOSED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALK BROKEN CONCRETE | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | 2ND FLOOR KITCHEN FLOOR ROTTED WOOD MISSING TILES | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR HALLWAY STAIR MISSING SMOKE DETECTOR | 3006 W WALNUT ST | COMPLAINT | CLOSED | View |
REPAIR DOOR HARDWARE | FRONT/REAR DOOR BROKE LOCKS/LOOSE HANDLE @2ND FLOOR | 3006 W WALNUT ST | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | REAR OPEN WOODEN PORCH COLUMN ERECTED ON SOIL UPRIGHT COLUMN ROTTED OUT OF PLUMB LEDGER BOARD BEAMS ROTTED AND STRINGERS ATTACHED TO BUILDINGS EXTERIOR WALLS WITH NAIL UNDERSIZE 2X8 FLOOR JOISTS OPERATED THAN 10' SPANS FLOOR JOISTS ARE TOE NAILED TO HEADER JOISTS THRU-OUT STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMN RAILING SECTIONS LESS 42" HIGH,LOOSE AND PULLING AWAY D&H | 3006 W WALNUT ST | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLAN AND PERMIT TO REPLACE REAR OPEN WOODEN PORCH | 3006 W WALNUT ST | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | (SR#07-00878269) - FRONT STAIRS - COLUMNS ARE RESTED ON SOIL AND LOOSE. ROTTED TREADS, RISERS, DECKBOARDS, GUARDRAIL. SYSTEM SWAYS UPON WALL. IMPROPERLY CONNECTS - MOST MEMBERS ARE TOE NAILED TOGETHER AND SEPARATING AT THE CONNECTIONS. POSTED DANGEROUS AND HAZARDOUS. PLANS AND PERMIT ARE REQUIRED FOR REPLACEMENT. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMIT ARE REQUIRED FOR RECENTLY CONSTRUCTED REAR PORCH. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS - ROTTED AND BROKEN WINDOW FRAMES. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH - TORN, LOOSE AND MISSING SHINGLES. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | APT. 2 - LOOSE WALL OUTLET. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR - FRACTURED AND SPALLING CONCRETE. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | APT. 2 - KITCHEN FLOOR IS ROTTED AND MISSING TILES. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY - MISSING SMOKE DETECTORS. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | FRONT, REAR AND APT. 2 ENTRY DOORS - BROKEN LOCKS AND LOOSE HANDLES. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS OF EXISTING 2 STORY MASONRY HOUSE INCLUDING BUT NOT LIMITED TO:ERECTING NEW PARTITIONS IN FIRST AND SECOND FLOOR.REMOVED BASEMENT CONCRETE AND EXVAVATING DEEPER. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 3006 W WALNUT ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 3006 W WALNUT ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 3006 W WALNUT ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 3006 W WALNUT ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 3006 W WALNUT ST | COMPLAINT | CLOSED | View | |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS OF EXISTING 2 STORY MASONRY HOUSE INCLUDED BUT NOT LIMITED TO:ERECTING NEW PARTITIONS IN FIRST AND SECOND FLOOR.REMOVED BASEMENT CONCRETE AND EXCAVATING. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 3006 W WALNUT ST | PERMIT | PASSED | View | |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 1ST/ BASEMENT TO VERIFY SMOKE ORIGINAL | 3006 W WALNUT ST | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 3006 W WALNUT ST | COMPLAINT | CLOSED | View | |
BLANK-TEXT MUST CITE CODE SECT | 80, 13-32- STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 13-13-0035. | 3006 W WALNUT ST | COMPLAINT | FAILED | View |