The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | 7838 APARTMENT 1-E ROOM TEMPERATURE OF 65 DEGREES WITH STOVE @ 10:55 AM HEATING SYSTEM NOT IN SERVICE AT TIME OF INSPECTION | 7836 S ADA ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 7838 APARTMENT 1-E HOT WATER TEMPERATURE OF 65 DEGREES INADEQUATE HOT WATER SERVICE | 7836 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | ALL ENTRANCE DOORS OF 7836-38: GLASS PANES BROKEN | 7836 S ADA ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | PEEPHOLE MISSING, 7838, APT. 3W | 7836 S ADA ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | NON WORKING SMOKE DETECTOR-7838, APT. 3W | 7836 S ADA ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | DEFECTIVE WALL OUTLET, 7838, APT. 3W | 7836 S ADA ST | COMPLAINT | FAILED | View |
PROVIDE KIT SNK TO FAMILY UNIT | PEELING PAINT ON BATHROOM SINK, 7838, APT. 3W; AND BROKEN BATHROOM SINK, 7838, APT. 2E | 7836 S ADA ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | BROKEN FLOOR TILES, 7838, APT. 2E, KITCHEN | 7836 S ADA ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 7838, REAR PORCH SYSTEM: LOOSE GUARD RAIL AT 2ND FLOOR, LOOSE & UNDERSIZED GUAD RAIL AT 1ST FLOOR-LESS THAN 42" HIGH, NO BOLTS ON STRINGERS & LEDGERBOARDS, NO JOIST HANGERS THRU-OUT, INCLUDING 7836 REAR PORCH, LOOSE GUARD RAIL AT 3RD FLOOR, 7836, ALSO, NO BOLTS ON STRINGERS & LEDGERBOARDS; PERMIT ONLY REQUIRED FOR 7836-38, REAR PORCH REPAIRS; NO PLANS NEEDED | 7836 S ADA ST | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | STAGNANT & SEWAGE WATER ON REAR BASEMENT, 7838 | 7836 S ADA ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNERSHIP I.D. SIGN NOT POSTED | 7836 S ADA ST | COMPLAINT | FAILED | View |
CARPETING | TORN CARPET-7838, FRONT INTERIOR STAIRWAY | 7836 S ADA ST | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | SEWER ODOR AT 7838, REAR YARD | 7836 S ADA ST | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | ROD MAIN SEWER 18.29.102.3 18.29.301.3 | 7836 S ADA ST | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | MUST ALSO REMOVE RESIDUE 18.29.705.1 THRU 16 | 7836 S ADA ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BSMT | 7836 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT BASEMENT STAIRS - NO HANDRAIL | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTHWEST STAIRS - BROKEN CONCRETE | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTHWEST OPEN WOOD PORCH - GRADE TO 1ST FLOOR WINDER TREAD LOOSE; GRADE TO 1ST FLOOR STAIR STRINGER SPLIT WOOD; GRADE TO 3RD FLOOR STAIR STRINGERS NAILED; 4X4 COLUMNS UNDERSIZED; 4X4 COLUMN SPLICES INSUFFICIENT,TOO SMALL; LEDGER BOARDS NAILED TO WALL; GUARDRAILS HAVE WARPED MEMBERS AT VARIOUS LOCATIONS; GUARDRAILS LESS THAN 42" HIGH; GUARDRAILS NAILED TO WALLS; LOOSE AND WORN DECKING; TOP TREAD AT 3RD FLOOR WEAK; NAILS PULLED AWAY FROM WOOD AT VARIOUS LOCATIONS; 3RD FLOOR BURN MARKS IN DECKING; LOOSE AND PEELING PAINT THRU-OUT; PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT OF PORCH. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTHEAST OPEN WOOD PORCH - LEDGER BOARDS,STAIR STRINGERS,GUARDRAILS AND COLUMN SPLICES ARE NAILED; 4X4 COLUMNS UNDERSIZED; 4X4 COLUMN SPLICES INSUFFICIENT,TOO SMALL; 4X4 COLUMNS ARE NOT PROPERLY ATTACHED TO ROOF; 2ND FLOOR GUARDRAIL ROTTED WOOD AT TOP MEMBER; ALL LEVELS GUARDRAILS LESS THAN 42" HIGH; 2X8 JOISTS UNDERSIZED FOR 11'-5" DECK SPAN; RISER BOARDS SPLIT WOOD AT VARIOUS LOCATIONS; ROTTED WOOD AT ROOF BOARDS; PEELING PAINT; PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT OR PORCH. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT BASEMENT DOOR - GAP AT BOTTOM OF DOOR | 7836 S ADA ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT BASEMENT STAIRS - NO GUARDRAILS | 7836 S ADA ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR AT TIME OF 2009 ANNUAL INSPECTION; UNVERIFIED CONDITIONS AND DETECTORS. | 7836 S ADA ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED ON BUILDING | 7836 S ADA ST | PERIODIC | FAILED | View |
CHIMNEY | SOUTHWEST CHIMNEY - WASHED OUT MORTAR. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTHEAST OPEN WOOD PORCH - LEDGER BOARDS,STAIR STRINGERS,GUARDRAILS AND COLUMN SPLICES ARE NAILED; 4X4 COLUMNS UNDERSIZED; 4X4 COLUMN SPLICES INSUFFICIENT,TOO SMALL; 4X4 COLUMNS ARE NOT PROPERLY ATTACHED TO ROOF; 2ND FLOOR GUARDRAIL ROTTED WOOD AT TOP MEMBER; ALL LEVELS GUARDRAILS LESS THAN 42" HIGH; 2X8 JOISTS UNDERSIZED FOR 11'-5" DECK SPAN; RISER BOARDS SPLIT WOOD AT VARIOUS LOCATIONS; ROTTED WOOD AT ROOF BOARDS; PEELING PAINT; PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT OR PORCH. | 7836 S ADA ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTHWEST BASEMENT STAIRWAY - GRADE TO BASEMENT AT GRADE - '' LADDER'' TYPE GUARDRAILS - ONLY 28'' HIGH - MISSING PICKETS - 9'' TO 12'' SPACE BETWEEN HORIZONTAL TIES. | 7836 S ADA ST | PERIODIC | FAILED | View |
WINDOW AREA ABOVE GROUND | SOUTH AND WEST ELEVATIONS / BASEMENT WINDOW OPENINGS FILLED IN WITH BRICKS RECENTLY , REDUCING NATURAL LIGHT AND VENTILATION. | 7836 S ADA ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FOR 2010 AND 2011. | 7836 S ADA ST | PERIODIC | FAILED | View |
CHIMNEY | SOUTHWEST CHIMNEY - WASHED OUT MORTAR. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTHEAST AND SOUTHWEST PORCHES - UNDERSIZED 4 X 4 COLUMNS OVERSPANNED AT 22' TO 28'. COLUMN SPLICES - LENGTH IS ONLY 8'' TO 14'' AND ONLY NAILED. STRINGERS ARE SPLIT -ONLY NAILED TO HEADER JOISTS , COLUMNS , AND MASONARY. DECK JOISTS ONLY NAILED TO LEDGER BEAMS. LEDGER BEAMS ONLY NAILED TO BUILDING. ROOF BEAMS ONLY NAILED TO COLUMNS. STAIR TREADS - LOOSE AND WORN . GUARD AND HANDRAILS - ROTTED AND LOOSE - PULLING AWAY FROM COLUMNS. GUARDRAILS ARE ONLY 38'' HIGH. DECKING IS ROTTED AND BUCKLED. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 7836 S ADA ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | 7836 S/ SOUTHWEST GRADE TO BASEMENT EXTERIOR STAIRWAYS - MISSING GUARD RAILS AT GRADE.(28 INCH DROP).7838 S./ SOUTH ELEVATION/ CENTER GRADE TO BASEMENT EXTERIOR STAIRWAYS NEAR EAST SIDE - MISSING GUARD RAILS AT GRADE.(23 INCH DROP). | 7836 S ADA ST | PERIODIC | FAILED | View |
WINDOW AREA ABOVE GROUND | SOUTH AND WEST ELEVATIONS / BASEMENT WINDOW OPENINGS FILLED IN WITH BRICKS RECENTLY , REDUCING NATURAL LIGHT AND VENTILATION. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTHWEST OPEN WOOD PORCH - GRADE TO 1ST FLOOR WINDER TREAD LOOSE; GRADE TO 1ST FLOOR STAIR STRINGER SPLIT WOOD; GRADE TO 3RD FLOOR STAIR STRINGERS NAILED; 4X4 COLUMNS UNDERSIZED; 4X4 COLUMN SPLICES INSUFFICIENT,TOO SMALL; LEDGER BOARDS NAILED TO WALL; GUARDRAILS HAVE WARPED MEMBERS AT VARIOUS LOCATIONS; GUARDRAILS LESS THAN 42" HIGH; GUARDRAILS NAILED TO WALLS; LOOSE AND WORN DECKING; TOP TREAD AT 3RD FLOOR WEAK; NAILS PULLED AWAY FROM WOOD AT VARIOUS LOCATIONS; 3RD FLOOR BURN MARKS IN DECKING; LOOSE AND PEELING PAINT THRU-OUT; PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT OF PORCH. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR LINTELS | FRONT ELEVATION/ BASEMENT WINDOW LINTELS - RUSTED.NORTH ELEVATION/ 1ST, 2ND AND 3RD FLOORS/ VARIOUS LINTELS (RANGING IN SIZE FROM APPROXIMATELY 30, 59 AND 78 INCHES) - RUSTED, SAGGING AND LARGE GAP ABOVE IS PACKED WITH HARD AND LOOSE MORTAR.PLAN AND PERMIT IS REQUIRED TO REPLACE ANY DEFECTIVE LINTEL OVER 6 FEET IN LENGTH.PERMIT ONLY IS REQUIRED TO REPLACE ANY DEFECTIVE LINTELS UNDER 6 FEET IN LENGTH.REPLACEMENT OF DEFECTIVE LINTELS COULD BE DETERMINED BY LICENSED MASONRY CONTRACTOR. SUBJECTED TO FIELD INSPECTION AND APPROVAL. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR CORNICE | FRONT AND NORTH ELEVATION/ ORNAMENTAL CORNICE STONES BELOW PARAPET WALLS - WASHED OUT MORTAR. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | SOUTH ELEVATION/ ALL LEVELS/ VARIOUS WINDOW SILLS - WASHED OUT MORTAR. | 7836 S ADA ST | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | NO PLANS FOR PERMIT # 100362521 OF 11/1/12 ON SITE FOR INSPECTOR'S REVIEW AT TIME OF INSPECTION. | 7836 S ADA ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | 7836-38 S./ ALL APARTMENTS - NO RESPONSE.UNABLE TO VERIFY DETECTORS, CINDITIONS, OCCUPANCY AND COMPLAINT OF ROACHES AND CEILINGS LEAKING, CAVING IN THROUGHOUT BUILDING.UNABLE TO INSPECT INTERIOR STAIRWAYS AND FINAL INSPECTION OF REAR PORCHES PER PLANS. | 7836 S ADA ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTHEAST AND SOUTHWEST PORCHES - UNDERSIZED 4 X 4 COLUMNS OVERSPANNED AT 22' TO 28'. COLUMN SPLICES - LENGTH IS ONLY 8'' TO 14'' AND ONLY NAILED. STRINGERS ARE SPLIT -ONLY NAILED TO HEADER JOISTS , COLUMNS , AND MASONARY. DECK JOISTS ONLY NAILED TO LEDGER BEAMS. LEDGER BEAMS ONLY NAILED TO BUILDING. ROOF BEAMS ONLY NAILED TO COLUMNS. STAIR TREADS - LOOSE AND WORN . GUARD AND HANDRAILS - ROTTED AND LOOSE - PULLING AWAY FROM COLUMNS. GUARDRAILS ARE ONLY 38'' HIGH. DECKING IS ROTTED AND BUCKLED. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 7836 S ADA ST | PERIODIC | FAILED | View |