Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROVIDE | EXIT DIAGRAMS NOT POSTED AS REQUIRED FOR THIS OCCUPANCY TYPE. (13-84-400) EXIT DIAGRAMS REQUIRED FOR PUBLIC PLACES OF ASSEMBLY. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE WOOD PLATFORM AND SPIRAL STAIR SYSTEM ATTACHED TO NEIGHBORING BUILDING AT SOUTH. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | IN SMALL LOUNGE AT SOUTH BUILDING EAST AND WEST INTERIOR DOORS SWING INWARD AND ARE 30 INCHES WIDE. DOORS MUST BE AT LEAST 36 INCHES WIDE AND SWING OUT. (13-160-220(A,9), (13-160-250) | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
POST APPROVED OCCUPANCY CARD | THIS SMALL ASSEMBLY TYPE OCCUPANCY OPERATING WITHOUT CAPACITY PLACARD. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
DOOR W/PANIC HRDWR-200+ ASMBLY | INSTALL PANIC STYLE HARDWARE AT ALL BUILDING EXIT DOORS. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
DOOR SWING IN DIR. OF TRAVEL | REHANG FOUR BUILDING EXIT DOORS TO SWING IN DIRECTION OF EXIT TRAVEL. EXISTING EXIT DOORS SWING-IN. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | REMOVE KEY OPERATED LOCK FROM EGRESS SIDE OF SOUTHEAST BUILDING EXIT DOOR. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FOR REAR EXITS PROVIDE UNINTERRUPTED ACCESS TO ALLEY. EXISTING CONDITION HAS REAR EXITS DISCHARGING INTO REAR YARD AND GATE TO ALLEY IS LARGE ASSEMBLY USED FOR VEHICLE ACCESS THAT IS ALSO CHAINED AND PADLOCKED. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | PROVIDE ONE HOUR FIRE RESISTIVE ENCLOSURE AT FURNACE. EXISTING ROOM DOES NOT PROVIDE REQUIRED FIRE SEPARATION. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | INSTALL SELF-CLOSING, SELF-LATCHING CLASS "B" FIRE DOOR ASSEMBLY AT FURNACE ENCLOSURE. EXISTING IS NOT A FIRE DOOR. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROVIDE | SMALL LOUNGE AREA AT SOUTHEAST CORNER OF BUILDING DOES NOT PROVIDE MINIMUM CEILING HEIGHT OF 7 FT.- 6 IN. EXISTING HEIGHT IS 7 FT.- 2 IN. (13-64-050) | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | REPLACE BROKEN FIRE EXTINGUISHER. DISCHARGE HOSE SEPARATED FROM CANISTER. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN ASSEMBLY | INSTALL CARBON MONOXIDE DETECTOR. CLUB OPERATING WITHOUT A DETECTOR. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
INTERIOR FINISH FIRERESISTANCE | PROVIDE FLAME SPREAD PROTECTION AT EXPOSED WOOD ROOF ASSEMBLY IN LARGE REAR BUILDING. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROVIDE | CORRIDOR IN CONNECTING LINK BETWEEN NORTH AND SOUTH BUILDINGS WITH CORRIDOR AT 36 INCHES WIDE THAT IS LESS THAN MINIMUM REQUIREMENT OF 44 INCHES. (13-160-270) | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | FRONT MIDDLE BUILDING, WOMEN'S BATHROOM - LAVATORY FLEXIBLE WATER SUPPLY TUBES MUST BE METAL. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | FRONT MIDDLE BUILDING, KITCHEN SINKS - P.V.C. WASTE PIPING MUST BE METAL. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROVIDE GREASE INTERCEPTOR | FRONT MIDDLE BUILDING, KITCHEN SINKS - INSTALL AN APPROVED GREASE TRAP. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | MIDDLE BUILDING FRONT, LAUNDRY TUB - NO TRAP AND PIPED WITH P.V.C. PIPE - MUST BE METAL. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | MIDDLE BUILDING FRONT, LAUNDRY TUB - INSTALL AIR CHAMBERS ON HOT AND COLD LINES. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPERLY | MIDDLE BUILDING FRONT, LAUNDRY TUB - FAUCET NOT ATTACHED TO FIXTURE. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | MIDDLE BUILDING FRONT, LAUNDRY TUB - NO VENT PIPING FOR FIXTURE. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | MIDDLE BUILDING FRONT, MENS BATHROOM - CLOSED FRONT TOILET SEATS, MUST BE OPEN FRONT. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | MIDDLE BUILDING FRONT, MENS BATHROOM - FLEX WATER SUPPLY TO TOILET AND LAVATORIES. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | MIDDLE BUILDING FRONT, MENS BATHROOM - P.V.C. PIPE TO LAVATORY WASTE MUST BE METAL. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
SUBMIT PLANS FOR PLUMBING PRMT | PROVIDE PLANS AND PERMITS FOR ALL PLUMBING INSTALLED. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | REMOVE ALL WATER, WASTE AND VENT PIPING INSTALLED WITHOUT A PERMIT. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANEL IN SOUTH FRONT AREA AND KITCHEN AREA OF BUILDING. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | PROPERLY INSTALL COVER TO ELECTRICAL PANEL IN SOUTH FRONT AREA OF BUILDING - DANGEROUS AND HAZARDOUS CONDITION. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT REAR CEILING AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR PIPES APART AT FITTINGS AT BAR COUNTERTOP AREAS, BARE WIRES TO HOT WATER HEATER, IN REAR CEILING AREAS WHERE CORDS ARE USED TO FEED LIGHTS, AND AT ELECTRICAL PANEL WHERE BARE WIRES ENTER AND LEAVE PANEL THROUGH WALLS THROUGHOUT THE ENTIRE BUILDING. DANGEROUS AND HAZARDOUS CONDITION. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN SWITCHES AND RECEPTACLES WITHOUT COVERS, OPEN JUNCTION BOXES WITH EXPOSED WIRES THROUGHOUT THE ENTIRE BUILDING. DANGEROUS AND HAZARDOUS CONDITION. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE ALL DEFECTIVE LIGHTS THROUGHOUT THE BUILDING. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | ALL BOXES SHALL BE ACCESSIBLE, COVERED AND COMPLY WITH THE DIMENSION REQUIREMENTS OF ARTICLE 370. THERE ARE BURIED JUNCTION BOXES IN WALLS AND JUNCTION BOXES SIZE ARE TOO SMALL THROUGHOUT THE BUILDING AREA. (18-27-370) | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROVIDE WEATHERPROOF BOXES, LIGHTS, FITTINGS AND APPROVED RACEWAYS AT FRONT AND SOUTH EXTERIOR AREAS OF BUILDING. (18-27-110.11) | 810 S TRIPP AVE | COMPLAINT | FAILED | View | |
REMOVE EXCESSIVE USE OF SEALTITE AT SOUTH EXTERIOR AREA OF BUILDING. (18-27-351.4B) | 810 S TRIPP AVE | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BUILDING WITHOUT INSPECTION. (13-12-380) | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BUILDING WITHOUT PLANS AND PERMITS. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
MAINTAIN REQUIRED CLEARANCES FOR SERVICE DROP CONDUCTORS. (18-27-230.24) | 810 S TRIPP AVE | COMPLAINT | FAILED | View | |
CONTRARY TO ORIGINAL PLAN | COMMERCIAL STORAGE BUILDING AND YARD CONVERTED TO PUBLIC PLACE OF ASSEMBLY DOING BUSINESS AS "TRIPP STREET SOCIAL CLUB". BUILDING IS ORGANIZED BY FOUR AREAS. FIRST SECTION IS AT MAIN ENTRANCE WHICH IS THE BAR AREA THAT IS APPROXIMATELY 15 FT. WIDE X 65 FT. LONG LOCATED ON THE NORTHEAST CORNER OF THE PROPERTY. IMMEDIATELY TO THE WEST OF THE BAR IS THE SECOND SECTION WHICH IS THE DANCE AREA THAT IS APPROXIMATELY 30 FT. WIDE BY 60 FT. LONG LOCATED AT THE NORTHWEST CORNER OF THE PROPERTY. THESE TWO AREAS ARE REFERRED TO AS THE NORTH BUILDING IN THIS REPORT. THERE IS A SOUTH BUILDING LOCATED AT THE SOUTHEAST CORNER OF THE PROPERTY THAT COMPRISES THE THIRD SECTION AND CONTAINS A SMALL LOUNGE, MENS ROOM AND SMALL STORAGE ROOM. THE NORTH AND SOUTH BUILDINGS ARE LINKED BY A SMALL STRUCTURE THAT CONTAINS A CONNECTING CORRIDOR, SMALL KITCHEN AND WOMEN'S ROOM. THE FOURTH AREA IS A LARGE OUTDOOR DECK BETWEEN THE NORTH AND SOUTH BUILDINGS. A SHIPPING CONTAINER ADJACENT TO THE SOUTH BUILDING PARTIALLY ENCLOSES THE OUTDOOR DECK. THE SOUTH HALF OF THE PROPERTY IS PRIMARILY A STORAGE YARD THAT IS OVERGROWN WITH WEEDS. AT THE SOUTHWEST CORNER OF THE YARD IS AN ABANDONED SEMI-TRUCK TRAILER SURROUNDED BY JUNK AND DEBRIS. AT THE ALLEY THERE IS A 10 FT. TALL FENCE AND VEHICLE GATE. ALONG THE SOUTH PROPERTY LINE IS A VACANT TWO FLAT. ON THE WALL OF THE TWO FLAT FACING THE YARD THE CLUB ERECTED A SMALL WOOD PLATFORM AT THE SECOND FLOOR AND SPIRAL STAIR SYSTEM. CAPACITY OF THE CLUB BASED ON FLOOR AREA IS AT LEAST 250 PERSONS. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PERMIT FOR ALL INTERIOR AND EXTERIOR ALTERATIONS. WORK INCLUDED BUT WAS NOT LIMITED TO: 1. CONVERSION OF COMMERCIAL STORAGE BUILDING AND YARD TO PUBLIC PLACE OF ASSEMBLY. 2. CONSTRUCTION OF ONE STORY MASONRY BUILDING AT NORTHEAST CORNER OF PROPERTY. 3. CONSTRUCTION OF GROUND LEVEL WOOD DECK BETWEEN NORTH AND SOUTH BUILDINGS. 4. CONSTRUCTION OF MENS AND WOMEN'S TOILET ROOMS. 5. INSTALLATION OF KITCHEN. 6. INSTALLATION OF FURNACE. 7. INFILL OF WINDOW OPENINGS WITH CONCRETE BLOCK. 8. INSTALLATION OF NEW EXTERIOR DOORS AND WINDOWS. 9. INSTALLATION OF BAR IN NORTH BUILDING. 10. INSTALLATION OF LOUNGE IN SOUTH BUILDING. 11. FENCE IN EXCESS OF 5 FT. IN HEIGHT. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REPLACE MISSING DOWNSPOUTS AT SOUTH ELEVATION OF NORTH BUILDING. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REMOVE OVERGROWTH OF WEEDS IN REAR YARD. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REMOVE ACCUMULATION OF JUNK AND DEBRIS AT INTERIOR AND EXTERIOR. 1. JANITOR'S CLOSET ADJACENT TO WOMEN'S ROOM CLOGGED WITH JUNK. 2. STORAGE ROOM AT WEST OF SOUTH BUILDING FULL OF JUNK AND DEBRIS. 3. ABANDONED SEMI-TRUCK TRAILER IN REAR YARD. 4. JUNK UNDER AND AROUND TRAILER. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PRV DISCHARGE PIPE FROM PRV | NORTH BUILDING FRONT, WATER HEATER UNDER BAR - RELIEF VALVE PIPING NOT PIPED TO FLOOR. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | NORTH BUILDING FRONT, BAR SINK WASTE - P.V.C. PIPE MUST BE METAL PIPE. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROVIDE ADEQUATE SUPPORT | NORTH BUILDING FRONT, BAR SINK WASTE - NOT SUPPORTED PROPERLY. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | NORTH BUILDING FRONT, BAR SINK - FLEXIBLE WATER SUPPLY TUBES, MUST BE METAL. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | NORTH BUILDING FRONT, BAR SINK - WATER LINES, NO AIR CHAMBERS. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
PROVIDE TRAP FOR FIXTURE | NORTH BUILDING FRONT - INSTALL A FLOOR DRAIN FOR WATER HEATER RELIEF VALVE PIPING. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |
INSTALL VENT PIPE FOR TRAP | FRONT MIDDLE BUILDING, WOMEN'S BATHROOM - LAVATORY P.V.C. WASTE PIPING MUST BE METAL. | 810 S TRIPP AVE | COMPLAINT | FAILED | View |