Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY CAPPING | CHIMNEY CAP MISSING | 6640 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR ENCLOSED ROOF - SAGGING IN VARIOUS LOCATIONS | 6640 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | ALL FLOORS - SMOKE DETECTORS MISSING | 6640 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND FIRST FLOOR - CARBON MONOXIDE DETECTORS MISSING | 6640 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT OPEN WOOD PORCH WITH ROOF -(1) ALL WOOD IN VARYING STAGES OF ROTT WITH JOINTS PULLING CREATING GAPS THAT EXPOSE RUSTING NAILS(2) JOIST HANGERS AND BOLTED CONNECTIONS MISSING(3) COLUMNS BEAR ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS(4) WEAK WOOD TREADS BEND WHEN STEPPED ON(5) PERMIT REQUIRED FOR REPAIRS | 6640 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT SPACES/ROOMS BUILT WITH NO PLANS OR PERMITS ON FILE. PLANS AND PERMITS REQUIRED FOR EXISTING ROOMS TO REMAIN OR DECONVERSION PERMIT REQUIRED TO RESTORE THE BASEMENT TO ONE LARGE OPEN SPACE/ROOM. | 6640 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR OF BUILDING REHAB WITHOUT PERMITS. 1ST FLOOR DUPLEXED WITH BASEMENT SPACE; PARTITION WALLS FORMED IN BASEMENT CREATING BEDROOMS AND BATHROOMS; 1ST AND 2ND FLOOR REAR DIVIDING / LOAD BEARING WALLS REMOVED CREATING OPEN KITCHEN CONCEPT AND LARGE BEDROOM; WALLS REPLACED APPEAR TO BE SUPPORTED WITH A BEAM SUPPORT - UNKNOWN SIZE AND COLUMN SUPPORTS; ALL WOOD LATH AND PLASTER REMOVED AND REPLACED WITH DRYWALL; ALL NEW ELECTRICAL AND PLUMBING FIXTURES; NEW HEATING AND VENTILATION EQUIPMENT, ALL THESE ALTERATIONS DONE WITHOUT PERMITS. SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, 1ST, AND 2ND FLOORS. | 6640 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED ONE STORY PORCH. 2X4 JOISTS FRAMING; 2X4 JOIST BEAM; 6X6 COLUMN ERECTED ON TOP OF CONCRETE SIDEWALK; 6X6 COLUMN OVERNOTCHED WITH SCAB BLOCKING; WOOD FRAME WALLS UNDERNEATH ENCLOSURE MISSING FOUNDATION AND RESTING ON GRADE; FRAMED WALLS APPEAR TO BE SEPARATING FROM MASONRY WALLS - LARGE GAPS BETWEEN WALLS AND MASONRY CONNECTING POINT. STAIR RISER HEIGHTS NOT UNIFORMED; STAIR RAILS LOOSE AND PULLING AWAY; STAIRS MISSING LANDING. SUBMIT PLANS AND OBTAIN PERMIT TO REPLACE REAR PORCH. (REMOVE AND REPLACE ENTIRE REAR PORCH). | 6640 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |