Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING, MISSING BUILDING OWNERS ID. SIGN. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | FRONT BUILDING, SOUTH BASEMENT AND 2ND FLOOR, NORTH BASEMENT WINDOWS HAVE BROKEN PANES. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | FRONT BUILDING, NORTH 2ND FLOOR WINDOW EXTERIOR CASING, MISSING ALUMINUM CAPPING. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | YARD HAS REFUSE ACCUMULATION, DRY TREE BRANCHES, FRONT BUILDING REAR PORCH AT 2ND FLOOR HAS JUNK. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR BUILDING, ATTIC GUARDRAIL HEIGHT IS 32", GUARD AND HANDRAILS HAVE HORIZONTAL RAILS, 8" APART, DEEP SIDE OF TREAD TO BOTTOM RAIL 12", (6" MAX). COLUMN TO BEAM CONNECTIONS MISSING STEEL ANGLES. FRONT BULDING REAR PORCH, 1ST FLOOR GUARDRAILS HEIGHT IS 32", COLUMN TO BEAM CONNECTION, MISSING STEEL ANGLES. PERMIT REQUIRED TO REPAIR PORCHES. FRONT BUILDING, FRONT PORCH, GUARDRAIL HEIGHT IS 32", GUARD AND HANDRAILS HAVE HORIZONTAL RAILS 8" APART, STRINGERS ARE OVER-NOTCHED BY LANDING CONNECTION AND TOENAILED TO RIM JOIST, 2X7" JOIST IS CRACKED AND SCABBED, BRICK RAIL PILLAR IS LEANINF AND LOOSE (WEST), LEDGER BOARD SUPPORTED BY A 1X2", AND ANCHORED TO EXTERIOR WALL WITH NAILS ONLY.PERMIT REQUIRED FOR REPAIRS. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BUILDING, FRONT STAIRS, STRINGER IS TOE-NAILED TO RIM JOIST, GUARD AND HANDRAILS PICKETS ARE ANCHORED TO TREADS WITH NAILS, SEVERAL ARE LOOSE, (MISSING BOTTOM RAIL), GUARDRAILS HEIGHT IS 36", LANDING JOISTS ARE MISSING JOIST HANGERS, LEDGER BOARD, ANCHORED TO EXTERIOR WALL WITH DECK SCREWS ONLY, PERMIT REQUIRED TO REPAIR. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
ILLUMINATE EXIT AREAS | REAR BUILDING, FRONT STAIRS, MISSING LIGHT FIXTURE. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 2ND FLOOR REAR BEDROOM ELECTIC OUTLET, MISSING COVER. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REAR BUILDING, FRONT BEDROOM MISSING LIGHT FIXTURE. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | REAR BUILDING, 2ND FLOOR, MISSING FLOOR TILES. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR BUILDING, 2ND FLOOR FRONT DOOR, MISSING DOORKNOBS. FRONT BUILDING, REAR DOOR AT GRADE, BOTTOM IS BENT, MISSING EXTERIOR DOORKNOB, AND HARD TO OPEN. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | REAR BUILDING, 2ND FLOOR, MISSING CARBON MONOXIDE DETECTOR. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
RELOCATE SMOKE DETECTOR | FRONT AND REAR BUILDING, REAR PORCHES, SMOKE DETECTOR NOT ON ATTIC LEVEL. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST SERVICE WALK, HAS HOLES, MISSING SECTION, HOLES AND ERODED CONCRETE. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | YARD HAS REFUSE ACCUMULATION, DRY TREE BRANCHES. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | FRONT BUILDING UNITS AND FRONT STAIRWAY AND REAR BUILDING 1ST FLOOR, NO ENTRY TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 3756 W GEORGE ST | COMPLAINT | FAILED | View |
DEFECTIVE POWER SERVICE | REAR BUILDING SERVICE TAMPERED WITH, EXPOSED & DAMAGED SERVICE CONDUCTORS IN ATTIC. IMPROPER OVER CURRENT PROTECTION. 1ST FLOOR PAYING, 2ND FLOOR ELECTRIC USAGE. DANGEROUS & HAZARDOUS | 3756 W GEORGE ST | COMPLAINT | PASSED | View |
ADD BRANCH CIRCUITS | COACH HOUSE 1ST, 2ND & ATTIC TO RELIEVE NUISANCE TRIPPING & USE OF EXTENSION CORDS | 3756 W GEORGE ST | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | COACH HOUSE ALL CONDUIT & CABLE 1ST, 2ND & ATTIC.PERMIT REQUIRED (D&H) | 3756 W GEORGE ST | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | REAR BUILDING 1ST & 2ND | 3756 W GEORGE ST | COMPLAINT | PASSED | View |
REPLACE ALL DAMAGED CLOTH WIRE AT CEILING BOXES DAMAGED BY HEAT. | 3756 W GEORGE ST | COMPLAINT | PASSED | View | |
INSTALL COVERS | REAR BUILDING THROUGHOUT | 3756 W GEORGE ST | COMPLAINT | PASSED | View |
NO PERMIT WIRING | COACH HOUSE REPAIRS MADE BY NOW LICENSED PERSON. REPAIRS ARE DEFECTIVE & DANGEROUS. LIGHTS RECEPTACLES & SERVICE (D&H) | 3756 W GEORGE ST | COMPLAINT | PASSED | View |