The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLCE WINDOW PANES, PLEXGLAS | ALL WINDOWS BOARDED WITH WOOD | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | BUILDING REFUSE AND GARBAGE IN THE BUILDING | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT EAST FENCE PADLOCKED WITH CHAIN | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH SERVICE WALKWAY SLABS BROKEN AND LOOSEN | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | SOUTH ELEVATION STRUCTURE EXTENDED | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO CARBON MONOXIDE DETECTOR IN THE BUILDING | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FOUNDATION CRACKS/FRACTURES ON BASEMENT WALLS | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | BROKEN GUTTERS AND DOWNSPOUT (SEC 18-29-1101-2-1) | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT AND REAR FENCE 5' | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY MISSING CAP | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL (OVERHANG-5 FEET X 26 FEET)-SOUTH 4X4 EDGE BEAMS WERE ADDED AND ONLY SET ON TOP OF SMALL PIECES OF LUMBER AND SPALLED MASONRY COLUMNS. EAST AND WEST 2X4 EDGE BEAMS ARE ONLY TOE NAILED INTO, AND SEPERATING AT THE NORTH EXTERIOR WALL CONNECTIONS. 2X4 BEAMS ARE SET ON TOP OF THE MASONRY COLUMNS AND ONLY TOE NAILED AND SEPERATING FROM THE 4X4 EDGE BEAM AND NORTH EXTERIOR WALL CONNECTIONS. 2X4 DECK JOISTS ARE ONLY TOE NAILED INTO AND SEPERATING FROM THE 2X4 BEAM CONNECTIONS; 2X4 DIAGNOL BRACING WAS ADDED TO THE DECK JOISTS UNDERSIDE FOR ADDITIONAL SUPPORT. (WEST) MISSING SIDING; EXPOSED PLYWOOD SHEATHING. SUBMIT PLANS / OBTAIN PERMIT FOR REPAIRS TO THE BUILDING OVERHANG. | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRS-(EAST 44 INCH HEIGHT; 8 SQ. FT.) ROTTED HEADER BEAM; FRACTURED, ROTTED STRINGERS; ROTTED TREADS; LOOSE RAILS; MOST MEMBERS ARE ONLY TOE NAILED TOGETHER AT THE CONNECTIONS. (WEST 44 INCH HEIGHT; 15 SQ. FT.) OUT OF PLUMB 4X4 COLUMNS; LEDGER IS ONLY SCREWED INTO THE EXTERIOR WALL CONNECTIONS; EDGE BEAM IS ONLY NAILED INTO THE COLUMN CONNECTIONS; DECK JOISTS ARE ONLY SCREWED INTO THE LEDGER / EDGE BEAM CONNECTIONS; WORN, OVERCUT STRINGERS ARE ONLY NAILED INTO THE HEADER BEAM CONNECTION; 2X4 MEMBERS WERE ADDED TO SUPPORT THE STRINGERS; FLIGHT SHIFTS LATERALLY UPON LOAD; LOOSE RAILS; HORIZONTAL 2X4 MEMBERS UTILIZED IN LIEU OF VERTICAL BALUSTERS AT RAILS. NO PERMIT REQUIRED FOR REPLACEMENT OF EAST / WEST EXTERIOR STAIRS. | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY-OPEN JOINTS; MISSING CAP. | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF (SOUTH SLOPE)-EXPOSED PLYWOOD SHEATHING. | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | GUTTERS-LOOSE; BENT. SOUTH DOWNSPOUT-MISSING. | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ENTRY DENIED (OCCUPANT AT THE REAR WINDOW)-UNVERIFIED COMPLAINT OF: SR#121893837-NO WORKING SMOKE DETECTORS. | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View | |
WINDOW REPAIR FOR AIR SEEPAGE | ALL WINDOWS ARE NOT WEATHER TIGHT ... EXTREMELY DRAFTY. | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View |
UNAPPROVED HEATING DEVICE | GAS LEAK AT THIS PROPERTY CAUSED PEOPLE'S GAS CO. TO DISCONECT SERVICE. THE TENANATS ARE USING ELECTRIC SPACE HEATERS AS A PRIMARY HEAT SOURCE. | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO GAS SERVICE ... NO HOT WATER AT THIS SINGLE FAMILY HOME. | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | MULTIPLE LEAKS IN THE PIPING THAT SUPPLIES GAS TO THE STOVE AND FURNACE ... DANGEROUS AND HAZARDOUS. | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTORS IN THIS SINGLE FAMILY HOME. | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE DETECTORS IN THE BASEMENT AND FIRST FLOOR OF THIS SINGLE FAMILY HOME. | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View |
HEAT UNIT ADEQUATELY | THERE ARE MULTIPLE LEAKS IN THE GAS SUPPLY PIPING CAUSING THE FURNACE TO BE INOPERABLE. NO HEAT. TEMPERATURE READING OF 43 DEGREES. DANGEROUS AND HAZARDOUS. | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View |
POST OWNER NAME OF VACNT BLDG | VIOLATIONS CLOSED WHEN INSPECTION IS CLOSED OR CANCELLED | 6440 S SEELEY AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | EAST AND WEST STAIR SYSTEM ROOFED AND WEAK | 6440 S SEELEY AVE | COMPLAINT | FAILED | View |