Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 31 Violations
Violation Inspector Comments Address Category Status View
REPLCE WINDOW PANES, PLEXGLAS ALL WINDOWS BOARDED WITH WOOD 6440 S SEELEY AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE BUILDING REFUSE AND GARBAGE IN THE BUILDING 6440 S SEELEY AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY FRONT EAST FENCE PADLOCKED WITH CHAIN 6440 S SEELEY AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY NORTH SERVICE WALKWAY SLABS BROKEN AND LOOSEN 6440 S SEELEY AVE COMPLAINT FAILED View
SUBMIT 2 COPY STRUCTURAL RPT SOUTH ELEVATION STRUCTURE EXTENDED 6440 S SEELEY AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO CARBON MONOXIDE DETECTOR IN THE BUILDING 6440 S SEELEY AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION FOUNDATION CRACKS/FRACTURES ON BASEMENT WALLS 6440 S SEELEY AVE COMPLAINT FAILED View
REPAIR OR REPLACE BROKEN GUTTERS AND DOWNSPOUT (SEC 18-29-1101-2-1) 6440 S SEELEY AVE COMPLAINT FAILED View
REPAIR FENCE FRONT AND REAR FENCE 5' 6440 S SEELEY AVE COMPLAINT FAILED View
CHIMNEY CAPPING CHIMNEY MISSING CAP 6440 S SEELEY AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL (OVERHANG-5 FEET X 26 FEET)-SOUTH 4X4 EDGE BEAMS WERE ADDED AND ONLY SET ON TOP OF SMALL PIECES OF LUMBER AND SPALLED MASONRY COLUMNS. EAST AND WEST 2X4 EDGE BEAMS ARE ONLY TOE NAILED INTO, AND SEPERATING AT THE NORTH EXTERIOR WALL CONNECTIONS. 2X4 BEAMS ARE SET ON TOP OF THE MASONRY COLUMNS AND ONLY TOE NAILED AND SEPERATING FROM THE 4X4 EDGE BEAM AND NORTH EXTERIOR WALL CONNECTIONS. 2X4 DECK JOISTS ARE ONLY TOE NAILED INTO AND SEPERATING FROM THE 2X4 BEAM CONNECTIONS; 2X4 DIAGNOL BRACING WAS ADDED TO THE DECK JOISTS UNDERSIDE FOR ADDITIONAL SUPPORT. (WEST) MISSING SIDING; EXPOSED PLYWOOD SHEATHING. SUBMIT PLANS / OBTAIN PERMIT FOR REPAIRS TO THE BUILDING OVERHANG. 6440 S SEELEY AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR EXTERIOR STAIRS-(EAST 44 INCH HEIGHT; 8 SQ. FT.) ROTTED HEADER BEAM; FRACTURED, ROTTED STRINGERS; ROTTED TREADS; LOOSE RAILS; MOST MEMBERS ARE ONLY TOE NAILED TOGETHER AT THE CONNECTIONS. (WEST 44 INCH HEIGHT; 15 SQ. FT.) OUT OF PLUMB 4X4 COLUMNS; LEDGER IS ONLY SCREWED INTO THE EXTERIOR WALL CONNECTIONS; EDGE BEAM IS ONLY NAILED INTO THE COLUMN CONNECTIONS; DECK JOISTS ARE ONLY SCREWED INTO THE LEDGER / EDGE BEAM CONNECTIONS; WORN, OVERCUT STRINGERS ARE ONLY NAILED INTO THE HEADER BEAM CONNECTION; 2X4 MEMBERS WERE ADDED TO SUPPORT THE STRINGERS; FLIGHT SHIFTS LATERALLY UPON LOAD; LOOSE RAILS; HORIZONTAL 2X4 MEMBERS UTILIZED IN LIEU OF VERTICAL BALUSTERS AT RAILS. NO PERMIT REQUIRED FOR REPLACEMENT OF EAST / WEST EXTERIOR STAIRS. 6440 S SEELEY AVE COMPLAINT FAILED View
CHIMNEY CHIMNEY-OPEN JOINTS; MISSING CAP. 6440 S SEELEY AVE COMPLAINT FAILED View
REPAIR ROOF ROOF (SOUTH SLOPE)-EXPOSED PLYWOOD SHEATHING. 6440 S SEELEY AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT GUTTERS-LOOSE; BENT. SOUTH DOWNSPOUT-MISSING. 6440 S SEELEY AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION ENTRY DENIED (OCCUPANT AT THE REAR WINDOW)-UNVERIFIED COMPLAINT OF: SR#121893837-NO WORKING SMOKE DETECTORS. 6440 S SEELEY AVE COMPLAINT FAILED View
SUBMIT FOR APPROVAL PLANS 6440 S SEELEY AVE COMPLAINT CLOSED View
MAINTAN BLDG IN SAFE CONDITION 6440 S SEELEY AVE COMPLAINT CLOSED View
REPAIR/WRECK DANGER RESID PREM 6440 S SEELEY AVE COMPLAINT CLOSED View
WATCHMAN 6440 S SEELEY AVE COMPLAINT CLOSED View
VACANT BUILDING - REGISTER 6440 S SEELEY AVE COMPLAINT CLOSED View
POST OWNER INFO ON ABDN BLDG 6440 S SEELEY AVE COMPLAINT CLOSED View
WINDOW REPAIR FOR AIR SEEPAGE ALL WINDOWS ARE NOT WEATHER TIGHT ... EXTREMELY DRAFTY. 6440 S SEELEY AVE COMPLAINT CLOSED View
UNAPPROVED HEATING DEVICE GAS LEAK AT THIS PROPERTY CAUSED PEOPLE'S GAS CO. TO DISCONECT SERVICE. THE TENANATS ARE USING ELECTRIC SPACE HEATERS AS A PRIMARY HEAT SOURCE. 6440 S SEELEY AVE COMPLAINT CLOSED View
SUPPLY HOT WTR MIN TEMP 120DEG NO GAS SERVICE ... NO HOT WATER AT THIS SINGLE FAMILY HOME. 6440 S SEELEY AVE COMPLAINT CLOSED View
SAFE WORKING CONDITIONS MULTIPLE LEAKS IN THE PIPING THAT SUPPLIES GAS TO THE STOVE AND FURNACE ... DANGEROUS AND HAZARDOUS. 6440 S SEELEY AVE COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTORS IN THIS SINGLE FAMILY HOME. 6440 S SEELEY AVE COMPLAINT CLOSED View
CARB MONOX DETECT IN RESID NO CARBON MONOXIDE DETECTORS IN THE BASEMENT AND FIRST FLOOR OF THIS SINGLE FAMILY HOME. 6440 S SEELEY AVE COMPLAINT CLOSED View
HEAT UNIT ADEQUATELY THERE ARE MULTIPLE LEAKS IN THE GAS SUPPLY PIPING CAUSING THE FURNACE TO BE INOPERABLE. NO HEAT. TEMPERATURE READING OF 43 DEGREES. DANGEROUS AND HAZARDOUS. 6440 S SEELEY AVE COMPLAINT CLOSED View
POST OWNER NAME OF VACNT BLDG VIOLATIONS CLOSED WHEN INSPECTION IS CLOSED OR CANCELLED 6440 S SEELEY AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR EAST AND WEST STAIR SYSTEM ROOFED AND WEAK 6440 S SEELEY AVE COMPLAINT FAILED View