OPEN TYPE VIOLATION | WORK INCOMPLETE / NOT READY FOR FINAL / WILL CALL | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | INSTALL MISSING GIBS AND BEND DOWN FIRE TABS. | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE MECHANICAL PROTECTION FOR TOP OF CAR WORK LIGHT. | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PIPE ELEVATOR MACHINE ROOM (EMR)LIGHTING PERMANENTLY | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE MECHANICAL PROTECTION FOR EMR LIGHTING | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE GFI RECEPTACLES IN EMR | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE MECHANICAL PROTECTION FOR EMR LIGHTING | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | REMOVE OR ENCLOSE ALL PIPING IN EMR NOT RELATED TO ELEVATOR OPERATION | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE GFI RECEPTACLES IN EMR | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE ABC RATED FIRE EXTINGUISHER IN EMR | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | TELEPHONE LINE TO BE IN APPROVED CONDUIT-EMR | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROPERLY FASTEN OIL LINE BRACKET IN EMR | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | CAR CALL BRAILLE TAGS MUST MATCH FLOOR DESIGNATES | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | INSTALL BRAILLE TAGS ON ALL LANDING DOOR FRAMES | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | INSTALL CERTIFICATE FRAME IN ELEVATOR CAB. | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | ADJUST DOORS TO FULLY OPEN | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE NUDGING BUZZER | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | INSTALL TOP ACCESS-TEST SAME | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | SEAL ESCUTCHEON HOLES THAT ARE NO LONGER IN USE | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE TEST WEIGHTS TO FINISH INSPECTION. | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | STENCIL INSIDE OF LANDING DOORS | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | INSTALL SWITCH ON ESCAPE HATCH | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE ABC RATED FIRE EXTINGUISHER IN EMR | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PROPERLY FASTEN OIL LINE BRACKET IN EMR | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | CAR CALL BRAILLE TAGS TO MATCH FLOOR DESIGNATIONS | 2501 W TOUHY AVE | PERMIT | FAILED | View |
REPAIR STOOP | FRONT STOOP CRACKED CONCRETE | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MANAGEMENT NOT POSTED | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY UNIT 204 CHECK SR#801874434 | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
OPEN TYPE VIOLATION | STENCIL INSIDE OF LANDING DOORS | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE MECHANICAL PROTECTION FOR TOP OF CAR WORK LIGHT. | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PIPE ELEVATOR MACHINE ROOM LIGHTING PERMANENTLY | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | REMOVE OR ENCLOSE ALL PIPING IN EMR NOT RELATED TO ELEVATOR | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PIPE ELEVATOR MACHINE ROOM LIGHTING PERMANENTLY | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | REMOVE OR ENCLOSE ALL PIPING IN EMR NOT RELATED TO ELEVATOR OPERATION | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE GFI RECEPTACLES IN EMR | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE ABC RATED FIRE EXTINGUISHER IN EMR | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | TELEPHONE LINE TO BE IN APPROVED CONDUIT-EMR | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROPERLY FASTEN OIL LINE BRACKET IN EMR | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | CAR CALL BRAILLE TAGS MUST MATCH FLOOR DESIGNATES | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | INSTALL BRAILLE TAGS ON ALL LANDING DOOR FRAMES | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | INSTALL CERTIFICATE FRAME IN ELEVATOR CAB. | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | ADJUST DOORS TO FULLY OPEN | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE NUDGING BUZZER | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | INSTALL TOP ACCESS-TEST SAME | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | SEAL ESCUTCHEON HOLES THAT ARE NO LONGER IN USE | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE TEST WEIGHTS TO FINISH INSPECTION. | 2501 W TOUHY AVE | PERMIT | PASSED | View |
REPAIR ROOF | ROOF LEAK ABOVE BATHROOM UNIT 404. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | PEELING PAINT/MOLD CEILING OF BATHROOM 404. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | STAIR SIGN NOT ILLUMINATED 3RD FLOOR WEST; ALSO 2ND EAST. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | MOTORCYCLE & LAWNMOWER STORED BASEMENT LANDING WEST STAIRS (FIRE SAFETY HAZARD; GASOLINE & BLOCKING EGRESS). | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | STAIR SIGN NOT ILLUMINATED 3RD FLOOR WEST; ALSO 2ND EAST. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | MOTORCYCLE & LAWNMOWER STORED BASEMENT LANDING WEST STAIRS (FIRE SAFETY HAZARD; GASOLINE & BLOCKING EGRESS). | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
NO ENTRY | NO ENTRY. EV006869 | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR DOOR HARDWARE | WEST INTERIOR STAIRWAY SYSTEM /DOOR AT 3RD FLOOR - CLOSER BROKEN, HANGING OFF; NOT LATCHING PROPERLY. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
REPAIR SCREENS | WEST ELEVATION /WINDOW SCREENS - RIPPED AT MULTIPLE LOCATIONS. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
HOLDOPEN DEVICE, STAIR 3+ FLRS | WEST INTERIOR STAIRWAY SYSTEM /DOORS - REMOVE HOLD OPEN DEVICE AT 2ND AND 4TH FLOORS. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
CLASS B DOOR IN STAIRWELL | ESAT AND WEST INTERIOR STAIRWAY SYSTEMS /DOORS - MISSING FIRE RATED LABELS. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION /WINDOW PANE - BROKEN AT 2ND FLOOR. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | MULTIPLE EXIT AND STAIR SIGNS NOT ILLIUMINATED AT TIME OF INSPECTION. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | WORKING TWO WAY COMMUNICATION (PHONE) REQUIRED IN ELEVATOR CAB. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | CLEAN ELEVATOR PIT. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR MALFUNCTIONING DOOR RESTRICTOR | 2501 W TOUHY AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | CLEAN ELEVATOR PIT | 2501 W TOUHY AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | DISCONTINUE THE PRACTICE OF MECHANICALLY BLOCKING BASEMENT CAR CALL. KEYED LOCK-OUT IS REQUIRED SO FIRE SERVICE OPERATES CORRECTLY. | 2501 W TOUHY AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE MONTHLY FIRE SERVICE TEST LOG ON SITE PER CODE REQUIREMENT. | 2501 W TOUHY AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PERFORM CATEGORY 1 TESTING OF PASSENGER ELEVATOR. TAG EQUIPMENT & PROVIDE REQUIRED DOCUMENTATION IN MACHINE ROOM. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR EMERGENCY 2-WAY COMMUNICATION (PHONE). | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR ALARMBELL. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR ELEVATOR CAB EMERGENCY LIGHTING. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL METAL CODE DATA PLATE ON ELEVATOR CONTROLLER WITH CORRECT CODE REFERENCE PERMANENTLY ENGRAVED. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR ELEVATOR CAB LIGHTING & PROPERLY PROTECT. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE CURRENT MONTHLY ELEVATOR FIRE SERVICE TEST LOG IN MACHINE ROOM. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL MISSING FIRE ALARM INITIATING DEVICES AT BASEMENT LANDING. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REMOVE ACCUMULATED DEBRIS FROM ELEVATOR PIT. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE CURRENT MONTHLY ELEVATOR FIRE SERVICE TEST LOG IN MACHINE ROOM (PREVIOUSLY CITED) | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL MISSING FIRE ALARM INITIATING DEVICES AT BASEMENT LANDING (PREVIOUSLY CITED) | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
OPEN TYPE VIOLATION | POST MANAGEMENT INFORMATION NEAR NEAR ENTRANCE | 2501 W TOUHY AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL FAIDS BASEMENT | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
OPEN TYPE VIOLATION | PIPE PHONE LINE | 2501 W TOUHY AVE | PERMIT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY INTO INTERIOR TO CHECK STAIRWAYS NOR EXISTENCE OF SMOKE DETECTORS. | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
SEE INSPECTOR COMMENTS | NOT COMPLETE | 2501 W TOUHY AVE | PERMIT | FAILED | View |
ARRANGE FOR RE-INSPECTION | WIP | 2501 W TOUHY AVE | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | INSTALL SWITCH ON ESCAPE HATCH | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | INSTALL MISSING GIBS AND BEND DOWN FIRE TABS. | 2501 W TOUHY AVE | PERMIT | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE MECHANICAL PROTECTION FOR EMR LIGHTING | 2501 W TOUHY AVE | PERMIT | PASSED | View |
REPAIR STOOP | FRONT STOOP CRACKED CONCRETE | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR EMERGENCY 2-WAY COMMUNICATION - PHONE (PREVIOUSLY CITED) | 2501 W TOUHY AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | WORKING ALARM BELL REQUIRED. | 2501 W TOUHY AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | WORKING EMERGENCY CAB LIGHTING AND MACHINE ROOM LIGHTING REQUIRED. | 2501 W TOUHY AVE | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF APT. #203: BED BUGS. | 2501 W TOUHY AVE | COMPLAINT | FAILED | View |