Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | FRONT PORCH-2X6 JOISTS OVERSPANNED AT 7'6", UKNOWN FOUNDATIONS, INSUFFICIENT CONNECTORS-BEAMS ,COLUMNS, GUARD AND HANDRAILS, GUARD RAILS UNDER 42", REAR 2 STORY OPEN WOOD PORCH- OPEN FIRE CUTS, MISSING JOIST HANGERS, 2X8 JOISTS AT 13', MISSING AND LOOSE PICKETS, MISSING AND LOOSE DECKING, OPEN BEAM POCKET IN BRICK, INSUFFICIENT CONNECTORS THROUGH OUT-BEAMS, COLUMNS, RAILINGS, STRINGERS-4X4 BEAMS AT 5'6" OVERSPANNED. LOOSE STAIR TREADS, ROTTED BEAMS AND COLUMNS, UNEVEN RISERS, PLANS AND PERMITS FOR REPLACING REAR PORCH. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT OPENING MISSING GUARD RAIL. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | EAST ROTTED WINDOW FRAMES. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | EAST STAIRWAY MISSING PICKETS, MISSING HANDRAIL SECTION. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT UNIT OR 2ND FLOOR UNIT. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER ID SIGN | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT WITH GAS HOT WATER HEATER MISSING SMOKE DETECTOR. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
RELOCATE SMOKE DETECTOR | EAST STAIRWAY RELOCATE SMOKE DETECTOR TO TOP OF STAIR. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT MISSING CARBON MONOXIDE DETECTOR. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING / NO RESPONSE TO BASEMENT TO VERIFY DETECTORS AND OCCUPANCY. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / NO OWNER'S I.D. SIGN POSTED. (NEW OWNER). | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST ELEVATION / GRADE TO BASEMENT / GUARDRAIL MISSING. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALK CRACKED AND BROKEN. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |
PARAPET | EAST PARAPET WASHED OUT MORTAR. | 2613 W ARMITAGE AVE | COMPLAINT | FAILED | View |