Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | FOUNDATION STATUS UNKNOWN - NOT ACCESSIBLE. TEMPORARY POST AND BEAM SUPPORTS ERECTED UNDER 1ST FLOOR DECK. COLUMNS OVERNOTCHED. COLUMNS BUTT-JOINED. 2ND FLOOR COLUMN/BEAM CONNECTION ROTTEN. UNDERSIZED 2" X 6" DECK JOISTS SPAN 12'. SCABBING THROUGHOUT. STRINGERS ATTACHED TO COLUMNS, POSTS AND DECK JOISTS WITH NAILS ONLY. TREAD DEPTH IS ONLY 9". RIM JOISTS ATTACHED TO COLUMNS AND POSTS WITH NAILS ONLY. RAILS ATTACHED TO EXTERIOR WALL, COLUMNS AND POSTS WITH NAILS ONLY. PLANS AND PERMITS REQUIRED TO REPAIR OR REPLACE REAR PORCH. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | BROKEN OFF HINGES. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | PANE BROKEN. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID. SIGN NOT POSTED. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | OPEN JUNCTION BOXES. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | NO PERMITS ON FILE FOR INSTALLATION OF 6 FORCED AIR FURNACES AND 6 HOT WATER HEATERS IN BASEMENT.. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | STAGNANT SEWER WATER. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
RATS | RAT HARBORAGE. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | NO HOT WATER. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | ERECTED 160 FEET OF 6 FEET WIRE SCREEN FENCE. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | FINES FOR WORK DONE WITHOUT A BUILDING PERMIT,SEC.13-12-080,13-32-035,SR#131536567 FOR INTERIOR REHAB,NEED ENTRY TO INSPECT. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | THE 7220-2CD FLOOR FURNACE IS INOPERABLE. AT 11:08 THE TEMPERATURE IN THIS UNIT WAS 39 DEGREES. DANGEROUS AND HAZARDOUS.CB132016 - HEAT DWELLING UNIT ADEQUATELY (14X-8-802.2, 14X-8-802.2.1 AND 14X-8-802.2.2 | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | THE 7220-2CD FLOOR FURNACE IS INOPERABLE.CB132036 - HEAT OCCUPIABLE WORK SPACES ADEQUATELY (14X-8-802.3, 14X-8-802.3.1 AND 14X-8-802.3.2) | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH ELEVATION / PARAPET - SPALLED MASONRY WITH WASHED OUT MORTAR. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR PORCH - STORING BBQ GRILL. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / WOOD AND COMPOSITE DECK / UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. STRINGERS - SPACED UP TO 51 INCHES APART. COMPOSITE DECKING USED FOR TREADS - SAGGING UNDER FEET. DECKING IS POORLY INSTALLED, LOOSE AND RAN SHORT OF FRONT RIM JOIST ( TRIPPING HAZARD ). ALL RAILINGS - FASTENED WITH NAILS ONLY. WEST ELEVATION / 3 STORY WOOD PORCH / STAIR TREADS AT 3RD FLOOR - CRACKED. 4X4 AND HANDRAIL AT GRADE - SINGED. PERMIT REQUIRED TO REPAIR WOOD PORCH.SUBJECT TO FIELD INSPECTION AND APPROVAL. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION AT REAR EXIT DOORS / BRICK OPENINGS HAVE BEEN CUT. BRICKS HAVE GAPS WHERE BRICK MEETS SECURITY GATES. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION / 3RD FLOOR WINDOWS - BOARDED WITH PLYWOOD. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO ENTRY, UNVERIFIED DETECTORS AND CONDITIONS. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRING. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. | 7220 S WENTWORTH AVE | COMPLAINT | FAILED | View |