The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | PORCH MISSING RISERS, STRAPPING COLUMN TO LOOKOUTS, INSUFFICIENT NUMBER OF BOLTS IN LEDGER. | 2434 W 60TH ST | PERMIT | CLOSED | View |
REPAIR PORCH SYSTEM | 2X4'S FASTENED TO MASONRY WITH CUT NAILS, NEED BOLTS. GUARD RAIL SYSTEM NEEDS CENTER SUPPORT ON 1ST AND 2ND FLOORS. ONE STRINGER NO BOLTS. | 2434 W 60TH ST | PERMIT | CLOSED | View |
INSPECT CONSTRUCTION WORK | CALL TO SCHEDULE PORCH PERMIT INSPECTION APPOINTMENT-MUST HAVE PLANS AND PERMIT ON SITE. | 2434 W 60TH ST | PERMIT | CLOSED | View |
INSPECT CONSTRUCTION WORK | ARRANGE FOR INSPECTION REGARDING RECENTLY ISSUED PORCH PERMIT | 2434 W 60TH ST | PERMIT | CLOSED | View |
REPAIR PORCH SYSTEM | BUILDING CONNECTION/PICKETS ON OUTSIDE OF GUARD RAIL NO SIMPSON TILES AT GUARD RAILS 2X10 2X12 LEDGERS FOR HEANGER NOT INSTALLED 2X8 USED INSTEAM GUARD RAILS MISSING 4X4 NEWLS EVERY 4FT ROOF COLUMNS AND BEAM CONNNECTIONS NO STEEL STRAPS IMPROPER SPLICES AND MISSING BOLTS VARIOUS LOCATIONS LEDGERS NOT BOLTED PROPERLY LOOSE BOLTS GUARD RAILS AT STAIR LANDING UNDER 42 STAIR LANDING LEGS THAN WIDTH OF STAIR AS PER PLANNED CONTRARZ TO PLANS SUBSTANDARD WORK | 2434 W 60TH ST | PERMIT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP POSTED. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | FRONT EXT. DOOR DON'T CLOSE PROPERLY. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR 1ST BARB-Q GRILL ON PORCH. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH AT 1ST - WINDOW PANE - BROKEN. EAST AT BASEMENT - WINDOW PANE -BROKEN. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
PARAPET | WEST PARAPET - WASHED OUT MORTAR. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE- UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR FENCE | SOUTH ELEVATION / GATE - DETACHED. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
PARAPET | WEST ELEVATION / MULTIPLE LOCATIONS - WASHED OUT MORTAR JOINTS AND SPALLING BRICKS.SOUTH ELEVATION / ENTIRE PERIMETER - LEANING TOWARDS ROOF.PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS / MULTIPLE LOCATIONS - MISSING WINDOW SCREENS. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE / NORTH ELEVATION - MISSING DOWNSPOUTS. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION / 1ST FLOOR - BROKEN GLASS PANE. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | SOUTH AND EAST ELEVATIONS- #B:LINEAR LENGTH 10FT.AND #9 LINEAR LENGTH 4FT.WINDOW LINTELS RUSTING AND SAGGING.PLANS AND PERMIT REQUIRED FOR REPLACEMENT DANGEROUS AND HAZARDOUS CONDITIONS. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION / 1ST FLOOR - BROKEN GLASS PANE. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | VARYING RISER HEIGHT/NO STEEL ANGLES BEAM POCKET AT | 2434 W 60TH ST | PERMIT | CLOSED | View |
DEBRIS, EXCESSIVE | REAR UNDER PORCH JUNK AND DEBRIS | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FOYER BROKEN PLASTER | 2434 W 60TH ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2014 - 2016. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS / MULTIPLE LOCATIONS - TORN WINDOW SCREENS. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S IDENTIFICATION SIGN MISSING. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | NORTH ELEVATION / RETAINING WALL - MISSING GUARDRAIL. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAY. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION / MULTIPLE LOCATIONS NEAR GRADE - PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION / MULTIPE LOCATIONS - WASHED OUT MORTAR JOINTS.SOUTH ELEVATION / 2ND FLOOR TOWARDS WEST END OF BUILDING - VERTICAL FRACTURE AT WINDOW SILL. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | NORTH ELEVATION / TWO STORY OPEN WOOD PORCH - EXCESSIVE DEBRIS AT FIRST FLOOR LANDING AND SERVICE WALK. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH ELEVATION / TWO STORY OPEN WOOD PORCH - 6X6 COLUMNS ON CONCRETE PIERS, FOUNDATION STATUS UNKNOWN. 6X6 COLUMNS SCABBED AT MULTIPLE LOCATIONS. 24 INCH HIGH LAP JOINTS AT 6X6 COLUMNS ANCHORED WITH ONLY TWO BOLTS AT EACH JOINT. 6X6 ROOF BEAMS PULLING FROM 6X6 COLUMNS. LOOSE AND PULLING RAILING SYSTEM THROUGHOUT. END BEAM INSUFFICIENTLY ANCHORED TO EXTERIOR WALL, END BEAM DOES NOT CARRY LATERAL LOAD MAKING ANCHORING INEFFECTIVE. UPPER AND LOWER ENDS OF STAIRS STRINGERS INADEQUATELY ANCHORED WITH NAILS ONLY. STAIR SYSTEMS MISSING CARRIAGE BOARD.PLANS AND PERMIT REQUIRED FOR REPAIRS / REPLACE OF TWO STORY OPEN WOOD PORCH. | 2434 W 60TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH ELEVATION / STAIRS FROM GRADE TO BASEMENT - MISSING HANDRAIL. | 2434 W 60TH ST | COMPLAINT | FAILED | View |