Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 4:45 PM
PIN: 13324110140000
Property Address: 1656 N MAYFIELD AVE
City - Zip: CHICAGO - 60639
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71210
2023 Tax District: 71001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 48 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL SR# 06-01544775 - FRONT OPEN JOINTS / FRACTURES / BULGING BRICKS NORTH. 1656 N MAYFIELD AVE COMPLAINT CLOSED View
PARAPET FRONT AND NORTH BOWED THRU-OUT / BRICKS BULGING OUT DANGEROUS LEANING OUTWARD AT FRONT AND INWARD TOWARDS ROOF AT REAR. 1656 N MAYFIELD AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR PORCH - 6"X 6" COLUMNS OUT OF PLUMB, SEVERELY TWISTED / BOWED, LEDGER BEAMS ONLY 2X6 (ROTTING) AND STRINGERS ATTACHED WITH NAILS ONLY, UNDERSIZED 2X6 FLOOR JOISTS TOE-NAILED TO LEDGER BEAMS, STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS. OBTAIN PLANS AND PERMITS TO MAKE NECESSARY REPAIRS TO REAR PORCH. 1656 N MAYFIELD AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTORS TOP OF STAIRWAY AT 2 / APARTMENT 1 1656 N MAYFIELD AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID NO CARBON MONOXIDE DETECTOR APARTMENT 1. 1656 N MAYFIELD AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING UNVERIFIED DETECTORS. 1656 N MAYFIELD AVE COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S I.D. SIGN NOT POSTED. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS NORTH, EAST ELEVATION - OPEN JOINTS AT WINDOW SILLS. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION - OPEN JOINTS, STEP FRACTURES, LOOSE BRICKS AT EXTERIOR WALL. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS NORTH ELEVATION - 1ST FLOOR, BASEMENT - CRACKED WINDOW PANES. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR SILL NORTH ELEVATION - DOORSILL IS CRACKED, SPALLED. 1656 N MAYFIELD AVE COMPLAINT FAILED View
PARAPET NORTH ELEVATION - OPEN JOINTS; WALL IS LEANING INWARD AT NORTHWEST CORNER. OBTAIN PERMIT FOR REPAIRS. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE EAST ELEVATION - CLOSER MISSING ON SECURITY DOOR. 1656 N MAYFIELD AVE COMPLAINT FAILED View
CHIMNEY SOUTH ELEVATION - OPEN JOINTS AT CHIMNEY. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED WEST ELEVATION - FELT PAPER IS PEELING OFF GARAGE; SOFFIT IS HANGING; GUTTERS AND DOWNSPOUT ARE MISSING. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION - REAR PORCH - 6X6 COLUMN IS OUT OF PLUMB AND SEVERELY TWISTED; 2X6 LEDGER BOARD IS ATTACHED TO EXTERIOR WALL WITH NAILS ONLY; STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS. SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS TO REAR PORCH. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR COPING NORTH ELEVATION - OPEN JOINTS AT COPING STONE. 1656 N MAYFIELD AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING-OWNER'S ID SIGN NOT POSTED. 1656 N MAYFIELD AVE COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS WEST ELEVATION-HIGH WEEDS IN REAR YARD. SOUTH ELEVATION ALSO. 1656 N MAYFIELD AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE WEST, SOUTH ELEVATIONS- TRASH, DEBRIS IN REAR AND SIDE YARDS; GREASE HAS BEEN POURED AROUND CATCH BASIN. BRICKS IN REAR YARD. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR FENCE WEST ELEVATION-REAR FENCE IS BROKEN AND LEANING AGAINST GARAGE. 1656 N MAYFIELD AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY WEST ELEVATION-AREAWAY IS CRACKED, UNEVEN. 1656 N MAYFIELD AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH WEST ELEVATION-REAR PORCH 6X6 COLUMN IS TWISTING AWAY FROM BEAM AT 2ND FLOOR CEILING-VERY UNSTABLE, 2X6 RIM JOISTS SPAN 6'-10' TO 1'-3", 2X6 JOIST IS CURVED /DEFLECTED AT LOWER LANDING; STEEL ANGLE BRACKETS MISSING AT BEAM (COLUMN CONNECTIONS; BOLTS MISSING AT RAILS, STRINGERS; RAIL HEIGHT IS ONLY 35 1/2", SPLICE JOINTS ARE ONLY 10" WITH (2)TWO LAG BOLTS; PERMIT REQUIRED FOR REPAIRS TO REAR PORCH. 1656 N MAYFIELD AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH WEST ELEVATION-GUARDRAIL MISSING AT GRADE FOR BASEMENT AREAWAY. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR WEST ELEVATION-HANDRAIL MISSING FROM GRADE TO BASEMENT. 1656 N MAYFIELD AVE COMPLAINT FAILED View
CHIMNEY CAPPING SOUTH ELEVATION-CHIMNEY CAP IS MISSING. 1656 N MAYFIELD AVE COMPLAINT FAILED View
CHIMNEY HEIGHT SOUTH ELEVATION-CHIMNEY HEIGHT IS LESS THAN 2'-0" ABOVE ROOF LINE. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED WEST ELEVATION- GARAGE - FELT PAPER IS PEELING OFF GARAGE, SOFFIT IS SAGGING GUTTERS AND DOWNSPOUTS ARE MISSING; ALUMINUM CAPPING MISSING AT FASCIA, SOFFIT, ROTTING WOOD IS EXPOSED. 1656 N MAYFIELD AVE COMPLAINT FAILED View
SELF-CLOSE CLASS B FIRE DOOR INTERIOR-FOYER-CLOSER MISSING ON FRONT ENTRY DOOR. 1656 N MAYFIELD AVE COMPLAINT FAILED View
2-HR HEATING PLANT ENCLOSURE BASEMENT- HOT WATER TANK IS NOT SEPARATED BY DRYWALL PARTITIONS. DRYWALL ENCLOSURE MISSING. 1656 N MAYFIELD AVE COMPLAINT FAILED View
UNDERSIDE STAIR 1HR FIRE RES BASEMENT-DRYWALL MISSING UNDERNEATH STAIRWELL. 1656 N MAYFIELD AVE COMPLAINT FAILED View
GRADE AND DRAIN LOT INTERIOR- BASEMENT- STAGNANT WATER NEAR INTERIOR STAIRWELL. 1656 N MAYFIELD AVE COMPLAINT FAILED View
ILLUMINATE PUBLIC STAIR/HALL INTERIOR FOYER- LIGHT OUT AT FRONT ENTRANCE. 1656 N MAYFIELD AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS INTERIOR STAIRWELL-SMOKE DETECTOR MISSING AT 2ND FLOOR. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIRWELL- WIDTH OF STAIRS IS ONLY 31 1/2- 32 1/2" WIDE. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR SILL EAST ELEVATION-DOOR SILL IS CRACKED, SPALLED. 1656 N MAYFIELD AVE COMPLAINT FAILED View
BLANK-TEXT MUST CITE CODE SECT BASEMENT-CEILING EXPOSED; DRYWALL MISSING. 1656 N MAYFIELD AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. REAR YARD - LOCKED GATES, UNABLE TO INSPECT REAR PORCH. 1656 N. / APARTMENT # 2 - NO ENTRY, UNABLE TO VERIFY COMPLAINT OF ROOF LEAKING IN LIVING ROOM. 1656 N MAYFIELD AVE COMPLAINT FAILED View
PARAPET EAST ELEVATION / PARAPET WALL - OUT OF PLUMB AND LEANING INWARDS; BULGING AND SHIFTING MASONRY. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR LINTELS NORTH AND EAST ELEVATIONS / MULTIPLE LOCATIONS / METAL LINTELS - SEVERELY RUSTED AND BENT. PERMIT ONLY REQUIRED FOR METAL LINTELS REPLACEMENT. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH AND EAST ELEVATIONS / EXTERIOR WALL / MULTIPLE LOCATIONS / MASONRY ABOVE WINDOWS - BULGING AND SHIFTING. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR DOOR HARDWARE INTERIOR DOOR FRONT HALLWAY NO DOOR HANDLE. 1656 N MAYFIELD AVE COMPLAINT FAILED View
REPAIR COPING STONE COPING ON NORTH AND EAST PARAPET WALLS OPEN JOINTS AND SHIFTING. 1656 N MAYFIELD AVE COMPLAINT CLOSED View
CHIMNEY CAPPING MISSING CHIMNEY CAP. 1656 N MAYFIELD AVE COMPLAINT CLOSED View
CHIMNEY CHIMNET SPALLED BRICK / OPEN JOINTS 1656 N MAYFIELD AVE COMPLAINT CLOSED View
REPAIR LINTELS NORTH ELEVATION - OPEN JOINT AT LINTEL. 1656 N MAYFIELD AVE COMPLAINT FAILED View
CHIMNEY CAPPING SOUTH ELEVATION - CHIMNEY CAP IS MISSING. 1656 N MAYFIELD AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE. UNABLE TO INSPECT INTERIOR, BASEMENT. UNVERIFIED DETECTORS. 1656 N MAYFIELD AVE COMPLAINT FAILED View