The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER INFO ON ABDN BLDG | POST OWNERS INFORMATION VACANT PROPERTY | 5517 S SHIELDS AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | POST ADDRESS VACANT OPEN 1ST FLOOR SOUTH 1ST FLOOR WEST WINDOWS NOT COMPLETELY BOARDED NORTH ELEVATION BASEMENT WINDOW AND EAST | 5517 S SHIELDS AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | ALL ELEVATION OVERGROWN TREE BUSHES GRASS FIRE HAZARD | 5517 S SHIELDS AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | ALL ELEVATION RAT HARBORAGE | 5517 S SHIELDS AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | WEST ELEVATION ROTTED EAVES AND FASCIA BOARDS | 5517 S SHIELDS AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR EXCESSIVE AMOUNT OF GARBAGE AND DEBRIS | 5517 S SHIELDS AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH PARTIAL INSPECTION LEDGER UNDERSIZED 2X4 COLUMNS BOARD RAILING 1ST FLOOR GUARDRAIL SYSTEM MISSING TREADS DAMAGED REPAIR REAR PORCH REPAIR PERMIT NEEDED | 5517 S SHIELDS AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | HIGH WEEDS. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | 4X4 COLUMNS INADEQUATE, FOUNDATION IS UNKOWN, NO JOIST HANGERS, TREADS AND DECK WORN AND WOOD SPLIT, RAILS ARE 39" HIGH. SUBMIT PLANS AND OBTAIN PERMIT. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
REPAIR FENCE | WEST ELEVATION GATE IS MISSING, EAST AND NORTH ELEVATION SECTION OF FENCE MISSING. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | DEBRIS THROUGHOUT REAR AND FRONT YARD. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
REGISTER/SECURE/INSURE-VACANT | BOARDED AND SECURE. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
NO POSTED ADDRESS | NO ADDRESS POSTED. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | OWNERSHIP IS NOT POSTED. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
DEFECTIVE METER EQUIPMENT | METERS MISSING COVERS EXPOSING LIVE VOLTAGE. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
REMOVE STAGNANT WATER BSMT | STAGNAN WATER AND DEBRIS. | 5517 S SHIELDS AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY AND 2ND. FL. /MISSING SMOKE DETECTEOR; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST. FL. /SMOKE DETECTOR - OUT OF SERVICE, WITH MISSING BATTERY; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | 2ND. FL. /MISSING CARBON MONOXIDE DETECTOR; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
INT WALL/CEILING CHIP PLASTER | 1ST. FL. /KITCHEN, REAR BEDROOM AND BATHROOM - WATER DAMAGE, PEELING PLASTER; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
PROV HOT WTR TO ALL FIXTURES | 2ND. FL. /KITCHEN AND WASHROOM FIXTURES - HOT WATER NOT PROVIDED; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
PROVIDE COLD WATER TO FICTURES | 2ND. FL. /KITCHEN FIXTURE - COLD WATER NOT PROVIDED; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
RESET LOOSE FIXTURE | BASEMENT /2ND. FL. WATER HEATER - NOT CONNECTED; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
REPAIR FLOOR | BASEMENT /CONCRETE FLOOR - CRACKED, BROKEN; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | BASEMENT /6X6 COLUMNS ERECTED ON SOIL, WITH NO BASES; FOUNDATION STATUS UNKNOWN;PLANS AND PERMIT REQUIRED TO REPLACE 6X6 COULMNS; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
CUT OR REMOVE HIGH WEEDS | NORTH, SOUTH AND REAR ELEVATION /WEEDS OVER 14 INCHES; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | CHIMNEY CAPPING /MISSING; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | REAR AND SOUTH ELEVATION /EXTERIOR FRAME WALLS - BULGING [WAVY];PERMIT ONLY REQUIRED FOR ALL REPAIRS;FRONT ELEVATION /WING WALL - MISSING STONE CAP; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION /SERVICE WALK - MISSING; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT ELEVATION /WOOD STAIR AND GUARD RAILING SECTIONS - LOOSE AND PULLING; DEFLECTING UNDER LOAD; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS /SCREWS ONLY;PERMIT ONLY REQUIRED FOR ALL REPAIR; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
REPAIR STOOP | FRONT ELEVATION /CONCRETE STOOP - CRACKED AT [SOUTH]; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | REAR 2 STORY WOOD DANGEROUS AND HAZARDOUS WOOD PORCH;FOUNDATION /COLUMNS ERECTED ON CONCRETE AND SOIL, FOUNDATION STATUS UNKNOWN;LEDGER BEAMS /FASTENED TO BUILDING EXTERIOR WALL, WITH NAILS /SCREWS ONLY;DECK JOISTS /1ST. AND 2ND. FL. DECKS - STACKED ON TOP OF 6X6 COLUMNS, WITH TOW NAILS /METAL GUSSETS ONLY;STRINGERS /UPPER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; LOWER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY;STAIRS /TREADS ONLY 9 ¼ INCHES WIDE; RISERS NOT UNIFORMED, RANGING FROM 6 INCHES TO 7 INCHES TO 7 3/4 INCHES; TREADS AND RISERS ¿ WORN OUT, LOOSE, CRACKED, BROKEN, WEAK; LANDING BETWEEN 1ST. AND 2ND. ¿ UNSTABLE; PULLING; SWAYING;DECKING /ROTTING, DAMAGED, BUCKLED UP, LOOSE;RAILINGS /GUARD RAILING SECTIONS ONLY 36 TO 37 1/2 INCHES HIGH ¿ ROTTING, LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS ONLY 30 INCHES HIGH ¿ ROTTING, LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS /SCREWS ONLY; PICKETS ¿ ROTTING, LOOSE, BROKEN; PLANS AND PERMIT REQUIRED TO REPLACE 2 STORY DANGEROUS AND HAZARDOUS WOOD PORCH WITH ROOF. PLANS AND PERMIT REQUIRED TO REPLACE REAR 2 STORY WOOD DANGEROUS AND HAZARDOUS WOOD PORCH; | 5517 S SHIELDS AVE | COMPLAINT | CLOSED | View |