Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY 8121 S 1ST FLOOR 55 DEGREES ROOM TEMPERATURE 8121 S COLES AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS FURNACE DEFECTIVE NOT CONNECTION TO GAS SUPPLY 1ST FLOOR APARTMENT 8121 S COLES AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID NO CARBON MONOXIDE DETECTOR 1ST FLOOR APARTMENT FURNACE ROOM 8121 S COLES AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS REPAIR DEFECTIVE OUTLET AND SWITCHES, 1ST FLOOR,1ST BEDROOM SOUTH WALL,1ST FLOOR,LIVING ROOM AND BATH,1ST FLOOR NORTH WALL KITCHEN 8121 S COLES AVE COMPLAINT FAILED View
ARMORED CABLE REMOVE EXCESSIVE USE OF ARMORED CABLE THROUGHOUT 1ST FLOOR ATTIC AND ELECTRICAL PANEL RUN IN A DANGEROUS AND HAZARDOUS MANNER NO CONNECTORS WERE USED AT ELECTRICAL PANEL AND JUNCTION BOXES 8121 S COLES AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS RESOLVE DANGEROUS AND HAZARDOUS CONDITIONS CAUSED BY UNPROVED WIRING METHODS AT ELECTRICAL PANELS, NO CONNECTIONS AT BOX ARMORED CABLE,UN-INSULATED OPEN CONDUCTORS AT ELECTRICAL PANEL, UN-STRAPPED BOX ARMORED CABLE 18-27-110.14 8121 S COLES AVE COMPLAINT FAILED View
EXPOSED WIRING DANGEROUS AND HAZARDOUS EXPOSED WIRING AT OPEN PANEL AND AT OPEN BOXES AT ATTIC 8121 S COLES AVE COMPLAINT FAILED View
NO PERMIT WIRING PROVIDE PERMIT FOR DANGEROUS AND HAZARDOUS WORK PERFORMED WITHOUT PROPER PERMITS, A PERMIT WILL BE REQUIRED TO CORRECT ELECTRICAL VIOLATIONS 8121 S COLES AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL; SIDING MISSING. 8121 S COLES AVE COMPLAINT FAILED View
GARAGE: DANGER S&S TEAR DOWN GARAGE EXTERIOR WALLS WOOD SIDING ROTTED AND BROKEN, WALL BUCKLING OUT, WOOD STUDE ROTTED. [SUBMIT PERMIT TO RAZE]. 8121 S COLES AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST PORCH; HAND RAILS AND GUARD RAILS ROTTED AND BROKEN, DECKING, TREADS AND STRINGERS SPLIT, REPLACE 4X4 WITH 6X6S.[SUBMIT PLANS AND PERMITS TO REPLACE].EAST ENCLOSE PORCH; UPRIGHT AND LOOKOUT ROTTED. 8121 S COLES AVE COMPLAINT FAILED View
INSTALL COVERS REPLACE MISSING OR BROKEN COVERS,1ST FLOOR BATH BROKEN,1ST FLOOR KITCHEN MISSING ATTIC CEILING AT BATH, ATTIC FRONT BEDROOM AT SWITCH,1ST FLOOR KITCHEN AT REAR DOOR SWITCH,1ST FLOOR AT SWITCH STAIR TO ATTIC 8121 S COLES AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR WEST AND SOUTH EXTERIOR DOORS; DRYROTTED. 8121 S COLES AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR. 8121 S COLES AVE COMPLAINT FAILED View