Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | FRONT ELEVATION/ EXTERIOR WALL - WASHED OUT MORTAR.EXTERIOR MASONRY WING WALLS - LOOSE BRICKS WITH WASHED OUT MORTAR. | 7914 S GREEN ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR 2-SRORY ENCLOSED PORCH/ BEAMS - ROTTED AND ONLY NAILED TO COLUMNS. UNDERSIZED 2X8 DECK JOISTS SPAN 10 -12 FEET. LARGE HOLE IN 2ND FLOOR DECK. STRINGERS - MISSING. PLAN REQUIRED FOR REPLACEMENT. PERMIT OBTAINED ON 5/13/14 | 7914 S GREEN ST | COMPLAINT | CLOSED | View |
REPAIR FENCE | NORTH ELEVATION/ REAR WOOD FENCE - SECTIONS BUCKLED AND LEANING OUT OF PLUMB. | 7914 S GREEN ST | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | SOUTH ELEVATION - CHIMNEY CAPPING - MISSING. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH ELEVATION - WOOD FENCE BROKEN, LEANING AND OUT OF PLUMB, WITH PICKETS LOOSE, BROKEN AND MISSING; WEST ELEVATION - SECTIONS OF FENCE MISSING. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION - EXTERIOR WALL - WASHED OUT MORTAR. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRWAY - WINGWALL AND 24 X 24 MASONRY COLUMN BRICKS MISSING, LOOSE AND WASHED OUT MORTAR; CONCRETE STEPS BROKEN; OPEN CEILING, WITH EXPOSED JOISTS. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | REAR ENCLOSED PORCH AT 1 - WINDOW SASH MISSING. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH AT 2 - WINDOW PANE CRACKED; REAR ENCLOSED PORCH WINDOW PANES BROKEN AND BOARDED UP. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR ENCLOSED PORCH AT 1 - WINDOW FRAME - ROTTING AND PEELING PAINT. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1ST FLOOR TO BASEMENT INTERIOR STAIRWAY - MISSING HAND RAIL. | 7914 S GREEN ST | COMPLAINT | CLOSED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR BASEMENT TO 2ND FLOOR STAIR SYSTEMS - MISSING HANDRAIL. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
COMPLETE WORK | INTERIOR OF BLDG: INCOMPLETE DRYWALLS, DOORS AND WINDOW TRIMS, HEATING AND VENTILATIONS. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
WORK CONTRARY TO PERMIT | WORK PERFORMED CONTRARY TO APPROVED PLANS AND PERMIT - NEW PARTITION WALLS AND INTERIOR ALTERATIONS OBSERVED - PLAN REVISION WITH PERMIT REQUIRED. WORK SUJECT TO FIELD INSPECTIONS AND APPROVAL BY ALL RELATED TRADES. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | SINGLE FAMILY HOUSE ALTERED INTO A HOME DAY CARE. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN BASEMENT, 1ST AND 2ND FLOOR CONTRARY TO APPROVED PLANS AND PERMIT. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION - CHIMNEY CAPPING - MISSING. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH ELEVATION - WOOD FENCE BROKEN, LEANING AND OUT OF PLUMB, WITH PICKETS LOOSE, BROKEN AND MISSING; WEST ELEVATION - SECTIONS OF FENCE MISSING. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH AT 2 - WINDOW PANE CRACKED; REAR ENCLOSED PORCH WINDOW PANES BROKEN AND BOARDED UP. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR ENCLOSED PORCH AT 1 - WINDOW FRAME - ROTTING AND PEELING PAINT. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | REAR ENCLOSED PORCH AT 1 - WINDOW SASH MISSING. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH ELEVATION/ CHIMNEY - MISSING CAPPING. | 7914 S GREEN ST | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | 2-STORY REAR ENCLOSED PORCH IS IN DANGEROUS AND HAZARDOUS CONDITIONS: BEAMS ROTTING AND ONLY TOE-NAILED TO COLUMNS; UNDERSIZED 2X8 DECK JOISTS SPAN 11 TO 12 FEET AND ONLY TOE-NAILED TO RIM BEAMS; LARGE HOLE ON 2ND FLOOR DECK, WITH STRINGERS AND STAIR SYSTEM MISSING - PORCH IS NOT ACCESSIBLE. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 7914 S GREEN ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT REVISED PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, 1ST AND 2ND FLOOR, OR RESTORE THE BUILDING TO ITS ORIGINAL STATE. | 7914 S GREEN ST | COMPLAINT | FAILED | View |