Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | EAST ELEVATION,GRADE TO 1ST FLOOR STAIRS,STRNGERS ARE SPLIT,TREADS ARE ROTTED WITH POPPING NAILS, RISERS ARE ROTTED,RAILINGS HAS PICKETS 8 INCHES APART.PERMIT FOR REPAIRS. | 720 W 48TH PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 4 BY 6 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN.LEDGER IS FACED NAILED ONLY.JOISTS ARE 2 BY 8 AND SPAN OVER 11-FEET FACE NAILED ONLY.COLUMNS OVER NOTCHED AT RIM-JOISTS.RAILINGS ARE 36 INCHES HIGH MISSING PICKETS.STRINGERS ARE FACE NAILED AT TOP CONNECTION,TREADS SPLITTING,RISER BOARDS ROTTED AND CRACKED.DECKING BOARDS ARE 1 BY 6 ,CUPPING AND SPLITTING.PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT. | 720 W 48TH PL | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | NORTH ELEVATION,GARAGE WITH ROTTED EAVES,OVER HEAD DOOR BOTTOM PANEL ROTTED. | 720 W 48TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO CHECK OCCUPANCY,DETECTORS. | 720 W 48TH PL | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING NO OWNERS I D SIGN POSTED. | 720 W 48TH PL | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REPLACE ALL PLASTIC WATER PIPE UNDER KITCHEN SINK 1ST FLOOR LAVATORY IN BASEMENT AND NEAR WATER HEATERS IN BASEMENT | 720 W 48TH PL | COMPLAINT | FAILED | View |
STOP LEAKING WATER | IN BATHROOM CEILING IN BASEMENT | 720 W 48TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | SR#10-00419776 | 720 W 48TH PL | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | WEST ELEVATION,DOWNSPOUT MISSING AT GRADE. | 720 W 48TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO CHECK OCCUPANCY,DETECTORS. | 720 W 48TH PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST AND WEST ELEVATION,SERVICE WALK WITH BROKEN AND MISSING CONCRETE. | 720 W 48TH PL | COMPLAINT | FAILED | View |