Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | SR#06-01325604 NORTH - BRICK FRACTURES / OPEN JOINTS | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH SPALLED BRICKS OPEN JOINTS | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | REAR OF BUILDING OVER BASEMENT ENTRANCE ROTTED ROOFING MATERIALS / ROTTED WOOD. | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR ENTRANCE TO BASEMENT STAIRS GATED AND PADLOCKED | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT GRADE TO 1 STAIRS CONCRETE SPALLED, ERODED, REAR GRADE TO BASEMENT STAIRS WOOD TREADS CRACKED / ROTTED, REAR GRADE TO 1 STAIRS TREADS ROTTED NO RISERS, ENTRANCE DECK AT REAR - RAILING ONLY 30" HIGH, LOOSE BOTTOM RAILS ON STAIRS LOOSE AND PULLING, LEDGER NAILED ONLY TO EXTERIOR WALL OF ENCLOSED PORCH. OBTAIN PERMITS FOR ALL REPAIRS TO FRONT AND REAR STAIR / DECK SYSTEMS. | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING UNVERIFIED DETECTORS AND OCCUPANCY | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER ID SIGN POSTED | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SR#06-01325604 SOUTH OPEN JOINTS BELOW ENTRANCE DOOR AT 1, SIDING AT ALLEY (WEST) BUCKLED / HOLES | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | EAST DANGEROUS AND HAZARDOUS PORCH SIGN POSTED / CAUTION TAPE COLUMNS ERECTED ON TOP OF CONCRETE SLAB, FOUNDATION STATUS UNKNOWN, COLUMNS ARE ONLY 4"X4" OUT OF PLUMB (BOWING TWISTING) WITH CRACKS THRU-OUT (2 STORIES) LEDGER BEAMS AND STRINGERS ATTACHED TO BUILDINGS EXTERIOR WITH NAILS ONLY VERY LOOSE. FLOOR JOISTS ARE TOE NAILED TO HEADER JOISTS THRU-OUT. STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS, STRINGERS DEPTH IS UP TO 7- 1/2 INCHES. RAILING SECTIONS ARE ONLY 30" HIGH, LOOSE AND PULLING, ESPECIALLY BOTTOM RAILS. DECKS ARE WEAK, WITH ROTTING FLOOR BOARDS. TREADS ARE CRACKED, WORN OUT, ONLY 8 INCHES WIDE. ENTIRE PORCH STRUCTURE IS UNSTABLE ANS SWAYING. OBTAIN PLANS AND PERMITS TO REPLACE 2 STORY REAR PORCH. | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
USE SANITARY REFUSE CONTAINERS | ALLEY AGAINST REAR BUILDING EXCESSIVE GARBAGE NOR IN REFUSE CONTAINERS | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
RATS | RATS IN GARBAGE PILE AGAINST BUILDING - ALLEY | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | TORN SCREENS THRU-OUT | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR APARTMENT DEFECTIVE SMOKE DETECTOR | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | SR#06-01325604 1ST AND 2ND FLOOR APARTMENTS NO CARBON MONOXIDE DETECTORS. | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 5610 INTERIOR STAIR SYSTEM 1ST TO 2ND FLOOR OBSTRUCTED COMPLETELY WITH TOOLS, JUNK AND CLOTHES | 1000 N CENTRAL AVE | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
FILE BLDG REGISTRATION | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
SUBMIT FOR APPROVAL PLANS | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | VIOLATION CLOSED PER PCR 1180 | 1000 N CENTRAL AVE | COMPLAINT | CLOSED | View |