Chicago Building Violations Data: 55 Violations
Violation Inspector Comments Address Category Status View
ARRANGE COMPLETED PERMIT INSP. 4726 S LOOMIS BLVD PERMIT FAILED View
ARRANGE COMPLETED PERMIT INSP. 4726 S LOOMIS BLVD PERMIT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH - APARTMENT 1R - WINDOW - BROKEN PANE;WEST - (GRADE) WINDOWS MISSING; BOARDED 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR FENCE CHAIN LINK FENCE - LEANING, UNSECURED; TOP RAIL MISSING 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR EXTERIOR STAIR 1ST FLOOR REAR DOOR - STAIRS MISSING; 93 1/2" DROP, FALL HAZARD 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR EXTERIOR DOOR 1ST FLOOR REAR DOOR - PAINT PEELING;1ST FLOOR FRONT DOOR - ROTTING WOOD; PAINT PEELINGREAR ENTRY DOOR (AT GRADE) - ROTTING 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL - SOUTH - SIDING MISSING AT REAR; WEST - WASHED OUT MORTAR; SPALLING BRICKS AT GRADE;NORTH - SIDING BUCKLING ABOVE 2ND FLOOR WINDOW; SPALLING AND MISSING BRICKS AT GRADE (REAR) 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME ENTRY DOOR (REAR AT GRADE) - ROTTING TRIM AND JAMB 4726 S LOOMIS BLVD COMPLAINT FAILED View
MAINTAIN WINDOW SASH REAR WINDOWS - ROTTING SASH, TRIM, FRAME, AND SILLS 4726 S LOOMIS BLVD COMPLAINT FAILED View
STOP/REMOVE NUISANCE GRAFFITI ON EXTERIOR WALL AT NW CORNER 4726 S LOOMIS BLVD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND ATTIC (IF ANY). UNVERIFIED DETECTORS AND OCCUPANCY. 4726 S LOOMIS BLVD COMPLAINT FAILED View
CHIMNEY CHIMNEY AT THE SOUTH ELEVATION OF THE PROPERTY MISSING BRICKS POORLY STABLYZED AND BARELY STANDING. REPAIRS NEEDED IN A VERY EMERGENCY MANNER CHIMNEY SHOWING SIGNS OF COLLAPSE. (DANGEROUS AND HAZARDOUS CONDITIONS.) 4726 S LOOMIS BLVD COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK FIRST FLOOR SHIFTING IN SUCH A MANNER THAT SHOWS SIGNS OF FAILING STRUCTURE BELOW A STRUCTURAL ENGINEER'S REPORT IS REQUIRED TO DETERMINE IF THIS AREA IS ABLE TO CARRY THE MINIMUM LOAD CAPACITY FOR THIS PROPERTY. (B) THE EXTERIOR WALLS ARE SPLAYING OUTWARD AND INWARD AT THE NORTH AND SOUTH ELEVATIONS SHOWING SIGNS OF FAILING A STRUCTURAL ENGINEER'S REPORT IS REQUIRED TO DETERMINE A SAFE FIX FOR THESE AREAS. (DANGEROUS AND HAZARDOUS CONDITIONS.) 4726 S LOOMIS BLVD COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) OBTAIN AN ENGINEERS REPORT TO DETERMINE IF THE STRUCTURAL ISSUES, AND BUT NOT LIMITED ALL OTHER ADDITIONS THAT MAY REQUIRE ENGINEERS APPROVALS. 4726 S LOOMIS BLVD COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN THE PROPER PLANS AND PERMITS FOR THE WORK THAT HAS BEEN PERFORMED AND THE WORK THAT HAS TO BE PERFORMED THROUGHOUT THIS PROPERTY. (ADDITION) 4726 S LOOMIS BLVD COMPLAINT FAILED View
STOP/REMOVE NUISANCE BULLET HOLES VISIBLE AT THE FRONT OF THE PROPERTY EAST ELEVATION. 4726 S LOOMIS BLVD COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE UNAPPROVED FLEXIBLE WATER SUPPLIES TO BATHROOM TOILET, LAVATORY AND KITCHEN SINK. 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS UNAPPROVED FLEXIBLE GAS HOSE SUPPLYING NATURAL GAS TO WATER HEATER IN KITCHEN. 4726 S LOOMIS BLVD COMPLAINT FAILED View
PRV DISCHARGE PIPE FROM PRV UNAPPROVED PVC TEMPERATURE AND PRESSURE RELIEF VALVE PIPING RAT WATER HEATER. PROVIDE RIGID METALLIC PIPING FROM VALVE AND TERMINATE 6" ABOVE FINISHED FLOOR. 4726 S LOOMIS BLVD COMPLAINT FAILED View
REMOVE WATER HEATER IN KITCHEN AREA LACKS PROPER ACCESS FOR OBSERVATION, MAINTENANCE, SERVICING OR REPLACEMENT. (18-29-502.6) 4726 S LOOMIS BLVD COMPLAINT FAILED View
RMV WATER,SOIL,WASTE,VENT PVC DRAINAGE PIPING OBSERVED IN KITCHEN CABINET STUBBED OUT OF WALL INDICATING NEW DRAINAGE PIPING INSTALLED WITHOUT PERMITS OR INSPECTIONS. 4726 S LOOMIS BLVD COMPLAINT FAILED View
OPEN REAR COACH HOUSE 2 INCH KITCHEN WASTE PIPING DISCHARGES INTO OPEN CLAY TILE SEWER WITHOUT PROPER SEALING AT BASEMENT. EXPOSING REAR COACH HOUSE TO DANGEROUS AND HAZARDOUS SEWER GASES 18-29-304.4 4726 S LOOMIS BLVD COMPLAINT FAILED View
INSTALL COVERS PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES WITH EXPOSED WIRES THROUGHOUT ALL ATTIC SPACE AREAS 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS LEAK IN GAS PIPING AT SECOND FLOOR FRONT HOUSE REAR UNIT ACCORDING TO PEOPLE'S GAS SHUT OFF REPORT 4726 S LOOMIS BLVD COMPLAINT FAILED View
STOP ODORS RPR DFT SEWAGE SYS REAR COACH HOUSE SHOWER DRAIN VENT TIED INTO 4 INCH SANITARY STACK VIA OVERSIZED SQUARE HOLE IN PIPE. UNAPPROVED TIE IS EXPOSING REAR COACH HOUSE TO DANGEROUS AND HAZARDOUS SEWER GASES 4726 S LOOMIS BLVD COMPLAINT FAILED View
OBTAIN ELECTRICAL PERMIT TO CORRECT VIOLATIONS 13-12-360 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS UNAPPROVED FLEXIBLE GAS SUPPLIES TO ALL WATER HEATERS IN ENTIRE BUILDING INCLUDING REAR COACH HOUSE 4726 S LOOMIS BLVD COMPLAINT FAILED View
PERMIT REQUIRED AT SOUTH ELEVATION, SECTIONS OF EXTERIOR WALLS ARE BEING REMOVED AND SECTIONS OF FLOORING HAVE BEEN CUT OUT. THIS IS A DANGEROUS AND HAZARDOUS CONDITION 4726 S LOOMIS BLVD COMPLAINT FAILED View
CONTINUITY OF RACEWAY PROVIDE GROUND CONTINUITY FOR BARE WIRES LOCATED THROUGHOUT ATTIC SPACE AREAS TO CONDUIT RUNS, DANGEROUS AND HAZARDOUS CONDITION 4726 S LOOMIS BLVD COMPLAINT FAILED View
ARMORED CABLE PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREA, BASEMENT AREA, AND GARAGE 4726 S LOOMIS BLVD COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NO HOT WATER DUE TO LACK OF NATURAL GAS AT FIRST FLOOR FRONT HOUSE FRONT UNIT AND SECOND FLOOR FRONT HOUSE REAR UNIT 4726 S LOOMIS BLVD COMPLAINT FAILED View
SCAVENGER SERVICE BUILDING MATERIAL FROM THE REMOVAL OF WALLS SECTIONS ARE BEING STORED AT THE REAR EXTERIOR OF THE BUILDING CREATING A RAT HARBORAGE. THIS IS A DANGEROUS AND HAZARDOUS CONDITION. 4726 S LOOMIS BLVD COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING. (18-29-106.1) 4726 S LOOMIS BLVD COMPLAINT FAILED View
EXPOSE FOR INSPECT APPROVAL EXPOSE PLUMBING SYSTEM FOR INSPECTION AND APPROVAL. 4726 S LOOMIS BLVD COMPLAINT FAILED View
OBTAIN PERMIT FOR PLUMBING OBTAIN PERMIT BEFORE CONSTRUCTING, ALTERING OR USING PLUMBING SYSTEM. (13-12-080, 13-32-010) 4726 S LOOMIS BLVD COMPLAINT FAILED View
DEFECTIVE FIXTURES NEED TO REPAIR EXTERIOR LIGHT AT FRONT ENTRANCE. 4726 S LOOMIS BLVD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING/ OWNERS ID SIGN- MISSING. 4726 S LOOMIS BLVD COMPLAINT FAILED View
CHIMNEY SOUTH ELEVATION/ 2 CHIMEYS- SPALLING BRICKS, WITH WASHED OUT MORTAR. 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION/ EXTERIOR WALL FROM 1ST FLOOR TO GRADE- WALL BULGING OUT AT 2 PLACES, AND OUT OF PLUMB. SOUTH, WEST, AND NORTH EXTERIOR WALLS AT REAR BUILDING- SPALLING BRICKS, WITH WASHED OUT MORTAR. 4726 S LOOMIS BLVD COMPLAINT FAILED View
SUBMIT 2 COPY STRUCTURAL RPT SOUTH ELEVATION/ EXTERIOR WALL FROM 1ST FLOOR TO GRADE- WALL BULGING OUT AT 2 PLACES, AND OUT OF PLUMB. 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPLACE D&H PORCH DANGEROUS AND HAZARDOUS REAR ENCLOSED 3 STORY PORCH/ COLUMNS- BEAMS AND JOISTS NOTCHED IN AT SAME LOCATION, SITTING ON SERVICE WALK, LEANING, AND OUT OF PLUMB.STRINGERS, JOISTS, AND LEDGER BEAMS- SCABBED SECTIONS, AND FASTENED WITH NAILS ONLY. GUARDRAILS WITH OPENINGS UP TO 30 INCHES [FALLING HAZARD]. ENTIRE STRUCTURE- WEAK, SAGGING, WITH EXPOSED WOODEN FRAMING AND ROOF SECTIONS.PLANS, AND PERMIT REQUIRED FOR REPLACEMENT OF: DANGEROUS, AND HAZARDOUS REAR 4726 S LOOMIS BLVD COMPLAINT FAILED View
HEAT UNIT ADEQUATELY FRONT BUILDING/ APARTMENTS #1F, AND 2R- GAS SHUTOFF, NO HEAT PROVIDED. APARTMENT #1F- 2 ADULTS, AND 2 CHILDREN AGES 3 AND 2. APARTMENT #2R- 2 ADULTS, AND 2 CHILDREN AGES 1, AND 9 MONTHS. 4726 S LOOMIS BLVD COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG FRONT BUILDING/ GAS SHUTOFF ENTIRE BUILDING- NO HOT WATER PROVIDED. 4726 S LOOMIS BLVD COMPLAINT FAILED View
PROV PRES/TEMP RLF VAL FOR HWH APARTMENT #2R- HOT WATER HEATER INSTALLED IN KITCHEN, ON COMBUSTIBLE FLOOR, WITH FLEX TYPE TUBING FROM GAS SUPPLY LINE, AND NO DRAIN PROVIDED FOR PRESSURE RELIEF VALVE PIPING [WOULD EMPTY ONTO FLOOR/ HAZARDOUS CONDITION]. 4726 S LOOMIS BLVD COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT BUILDING/ APARTMENTS # 1F, 2R, AND 2ND FLOOR THROUGH CORRIDOR- MISSING SMOKE DETECTORS. 4726 S LOOMIS BLVD COMPLAINT FAILED View
CARB MONOX DETECT IN RESID FRONT BUILDING/ APARTMENTS #1F, AND #2R- MISSING CARBON MONOXIDE DETECTORS. 4726 S LOOMIS BLVD COMPLAINT FAILED View
EXPOSED WIRING FRONT BUILDING ATTIC- ELECTRICAL BOX COVERS MISSING, WITH EXPOSED WIRING. 4726 S LOOMIS BLVD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS, AND OCCUPANCY. 4726 S LOOMIS BLVD COMPLAINT FAILED View
MICE/RODENTS ENTIRE BUILDING- RODENT/ RAT INFESTATION. 4726 S LOOMIS BLVD COMPLAINT FAILED View
DEBRIS, EXCESSIVE UNDER REAR ENCLOSED PORCH/ ACCUMULATION OF DEBRIS- 2 ABANDONED REFRIGERATORS, LARGE SCREEN TV, AND USED HOUSEHOLD ITEMS. 4726 S LOOMIS BLVD COMPLAINT FAILED View
MAINTAIN PROJECTIONS FRONT PORTICO - PEELING PAINT 4726 S LOOMIS BLVD COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE 1ST FLOOR REAR DOOR - HARDWARE MISSING 4726 S LOOMIS BLVD COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS WEEDS 4726 S LOOMIS BLVD COMPLAINT FAILED View
PROVIDE PLANS AND PERMITS FOR WORK DONE WITHOUT PERMITS FOR CONDUIT, BOXES, WIRING, DEVICES, AND EQUIPMENT (13-12-360) 4726 S LOOMIS BLVD COMPLAINT FAILED View
NEED ROUGH INSPECTION FOR RENOVATED UNITS THROUGHOUT ENTIRE BUILDING (13-12-380). 4726 S LOOMIS BLVD COMPLAINT FAILED View