The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO POSTED ADDRESS | NORTH ENTRY DOORS - ADDRESS MISSING DIGITS. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 2747 W./, SKYLIGHT WALLS - WATER DAMAGED DRYWALL. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | NORTH EXTERIOR DOOR AT 2737 W./ - SHATTERED GLASS PANE. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / NO OWNER'S ID POSTED | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNERS I.D. SIGN | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE, UNVERIFIED OCCUPANCY AND DETECTORS, UNABLE TO INSPECT REAR PORCHES. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT AREA / LAUNDRY ROOM AREA-MISSING SMOKE DETECOR. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT AREA / LAUNDRY ROOM AREA-MISSING CARBON MONOXIDE DETECTOR. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 5456-INTERIOR STAIRWAY / 3RD FLOOR CEILING-WATER STAINS,LOOSE AND BUCKLING PLASTER. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
REPAIR ROOF | 5456 / 3RD FLOOR INTERIOR STAIRWAY CEILING-WATER STAINS. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | 5456 / INTERIOR STAIRWAY 3RD FLOOR LANDING-BUCKLING FLOOR BOARDS. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
RESTORE EXIT AND EM | BUILDING / INTERIOR STAIRWAYS-EMERGENCY LIGHTING THROUGH OUT-NOT ILLUMINATING WHEN TESTED. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR YARD / DOG FECES. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 2737-43 REAR 3 STORY WOODEN PORCH.6X6 COLUMNS SET IN CONCRETE PADS,FOUNDATION STATUS UNKNOWN.BEAM AND COLUMN CONNECTIONS,ONLY TOE NAILED AT FIRE CUTS,SOME COLUMNS ARE SPLITTING.UNDER SIZED 2X8 JOISTS SPAN 10 FEET.LEDGER BEAMS MISSING BOLTS.STRINGERS ONLY FACE NAILED AT TOP CONNECTIONS.RAILINGS ONLY TOE NAILED TO SUPPORTS,MASONRY NAILED TO BUILDING,MISSING 4X4 CENTER SUPPORTS AT 10'SPAN.3RD FLOOR GUARD RAIL-ONLY 36 INCHES IN HEIGHT.1454-56 / REAR 3 STORY WOODEN PORCH.6X6 COLUMN SET ON SIDEWALK,FOUNDATION STATUS UNKNOWN.STRINGERS ONLY FACE NAILED AT TOP CONNECTION,MASONRY NAILED TO BUILDING.RAILINGS ONLY TOE NAILED TO SUPPORTS AND MASONRY NAILED TO BUILDING.2ND FLOOR RAILING IS ROTTED,LOOSE AND PULLED AWAY FROM SUPPORT.(FALL HAZARD,DANGEROUS CONDITION EXISTS.-RAILING AREA WAS CAUTION TAPED OFF) PLANS AND PERMIT REQUIRED FOR REPAIRS TO REAR PORCHES. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
REPAIR AREAWAY WALL | REAR ELEVATION / EAST AND WEST ELEVATIONS,ENCLOSED AREA WAY CEILINGS-PLYWOOD COVERED. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | 1454-56 REAR EXTERIOR PORCH AT 3RD FLOOR-2X12 PLANK SET ON RAILING- CONNECTS TO 2735 3RD FLOOR REAR PORCH RAILING. | 1454 N FAIRFIELD AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | 2735 W LEMOYNE 2ND FLOOR UNIT NO ENTRY UNABLE TO VERIFY OCCUPANCY, CONDITIONS OR DETECTORS | 1454 N FAIRFIELD AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | 2735 W LEMOYNE 1ST FLOOR UNIT KITCHEN AND PANTRY HOLES IN DRYWALL WATER DAMAGE CEILING AND WALLS | 1454 N FAIRFIELD AVE | COMPLAINT | PASSED | View |