POST OWNER/MANAGERS NAME/# | (SR#07-009244525) OWNERS I.D. SIGN IS NOT POSTED. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR FROM (G) TO (R)- MISSING HANDRAIL. REAR FROM (G) TO (I) - COLUMS ARE RESTED ON A CONCRETE BASE, FOUNDATION STATUS IS UNKNOWN. LEDGER IS ONLY NAILED INTO THE BUILDING CEPTER BEAM IS ONLY ONE 2X6 MEMBER. WORN THREADS LOOSE HAND AND GUARDRAILS WITH MISSING PICKETS. IMPROPER CONNECTIONS- MOST MEMBERS ARE TOENAILED TOGETHER AND ARE SEPERATED AT THE CONNECTIONS PERMIT IS REQUIRED FOR REPAIRS. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | LOOSE METAL TRIM AROUND THE OVERHEAD DOOR OPENING. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR- NO RESPONSE UNVERIFIED DECTORS, OCCUPANCY AND CONDITIONS. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH ELEVATION - CHIMNEY /BRICKS - CRUMBLING AT TOP. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | REAR ELEVATION - AREAWAY TO ALLEY /CONSTRUCTION EQUIPMENT AND MATERIAL - OBSTRUCTING PASSAGE TO ALLEY. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR OF BUILDING - TOP OF REAR STAIR /SMOKE DETECTOR - MISSING. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING /BASEMENT AND SECOND FLOOR - NO ENTRY. UNABLE TO VERIFY DETECTORS, CONDITIONS, AND OCCUPANCY. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | INTERIOR OF BUILDING /CONVERTED BASEMENT APARTMENT - NO PERMITS OBTAINED; REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT (ATTIC, 1ST FLOOR, 2ND FLOOR, ETC.) WITHOUT A PERMIT. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR OF BUILDING /CONVERTED BASEMENT APARTMENT - NO PERMITS ON FILE; PERMITS ARE NOW REQUIRED. SUBMIT PLANS AND OBTAIN A PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT (ATTIC, 1ST FLOOR, 2ND FLOOR, ETC.) OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 5755 S MEADE AVE | COMPLAINT | FAILED | View |