Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR FENCE | FENCE - BROKEN GATE - LYING ON GROUND; LEANING; UNSECURED | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST, SOUTH ELEVATIONS - SERVICEWALK - CRACKED WITH HOLES, TRIP HAZARD. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | WEST, EAST ELEVATIONS - TRASH, DEBRIS IN FRONT, REAR YARDS AND REAR BASEMENT AREAWAY | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH - SPINDLES MISSING; RAIL HEIGHT ONLY 31 3/4". PERMIT REQUIRED TO REPAIR FRONT PORCH. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | LOTS OF ANIMAL FECES IN FRONT YARD | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BASEMENT - WINDOWS - BOARDED | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS - SPINDLES MISSING IN SOME AREAS AND SPACED 6 1/4"-7" APART; HANDRAIL MISSING FROM GRADE TO BASEMENT. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | LUMBER, MATERIALS UNDERNEATH REAR STAIRS | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | BASEMENT - REAR DOOR - DEADBOLT LOCK MISSING | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. UNABLE TO INSPECT STAIRWELL, 2ND FLOOR APARTMENT, ATTIC, BASEMENT, AND REAR ENCLOSED PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID. SIGN NOT POSTED. | 6619 S MARYLAND AVE | COMPLAINT | CLOSED | View |
CUT OR REMOVE HIGH WEEDS | OVERGROWN. 18" HIGH. | 6619 S MARYLAND AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS.UNVERIFIED COMPLAINT OF: "" FRONT PORCH FALLING DOWN". | 6619 S MARYLAND AVE | COMPLAINT | CLOSED | View |
SUPPORT FIXTURES | CONDUIT LOOSE. | 6619 S MARYLAND AVE | COMPLAINT | CLOSED | View |
RMV OBSTRN FROM HSE DRAIN PIPE | ROD HOUSE SEWER | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY 1ST AND SECOND FLOOR | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR; PARTIALLY ENCLOSED PORCH-6X6 COLUMNS ARE ROTTED AT GRADE LEVEL; NORTH COLUMN IS PULLING AWAY FROM THE 6X6 BEAM. ROTTED 2X6 DECK JOISTS SUPPORTING THE FIRST FLOOR; UNDERSIZED JOISTS SPAN 10 FEET - 11 FEET TO CENTER BEAM; JOISTS ARE OVER SPACED AT 24 INCHES APART. FRACTURED, SCABBED STRINGERS FROM (GRADE) TO (1). MISSING BALUSTERS. NOTE: NO ENTRY INTO PORCH ENCLOSURE; UNVERIFIED CONDITION OF STRUCTURAL & NON-STRUCTURAL MEMBERS. OBTAIN PLANS / PERMIT FOR REPAIRS. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN-NOT POSTED. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRING-OPEN ELECTRICAL BOXES; OPEN CICUIT BREAKER BOX, MISSING ACCESS PANEL; LOOSE CONDUIT. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | EXTERIOR DOOR FRAME-BROKEN; SPLINTERED; UNABLE TO LOCK THE DOOR. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | METAL FENCE - LEANING; UNSECURED | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | WEST, EAST - DIRT, TRASH, DEBRIS THROUGHOUT FRONT AND REAR YARDS AND REAR PORCH. UNSANITARY CONDITIONS | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | EAST, WEST ELEVATIONS - TRASH, DEBRIS IN FRONT AND REAR YARDS; MATTRESS IN BASEMENT AREAWAY (EAST); REAR PORCH DECKS CLUTTERED WITH CARPET PADDING; LADDER, FISH TANK, BIKE, CRATES, ETC. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | GUTTER - MISSING | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | FRONT PORTICO/EAVE - LOOSE CAPPING IN SOME AREAS EXPOSING ROTTING WOOD | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | EAST, WEST ELEVATIONS - VERY TALL WEEDS, BUSHES GRASS IN FRONT AND REAR YARDS. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND CONDITIONS. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; BROKEN SPINDLE AT RAIL AT LANDING BETWEEN 1ST & 2ND FLOOR | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST AND 2ND FLR.APARTMENT, INTERIOR STAIR; NO SMOKE DETECTORS. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 1ST FLR.FURNACE IN BASEMENT UNDER WATER.2ND FLR.FURNACE BROKEN, [HAVING ELECTRICAL PROBLEMS]. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST AND 2ND FLR.NO CARBON MONOXIDE | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 1ST FLR. 63DG NO HEAT.2ND FLR.61DG NO HEAT | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1ST AND 2ND FLR.TENANTS USING STOVES AND ELECTRICAL HEATERS FOR HEAT. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | BASEMENT AND BACK YARD - FLOODED WITH SEWAGE WATER. PLUMING PERMIT REQUIRED TO CLEAN SEWER. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION - BOARDED UP WINDOW. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | CONDUIT LOOSE. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALKS-FRACTURED, SPALLED CONCRETE; WEEDS PROTRUDING OUT OF THE GAPS. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR - MISSING CARBON MONOXIDE DETECTOR. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING WINDOW SCREENS. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY AND 2ND FLOOR APT. - MISSING SMOKE DETECTOR. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST AND 2ND FLOOR ENTRY DOORS - MISSING VIEWING DEVICES. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD - REFUSE ACCUMULATION. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | 2ND FLOOR APT. ENTRY DOOR - MISSING DOORKNOB. | 6619 S MARYLAND AVE | COMPLAINT | FAILED | View |