The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CONNECT DOWNSPOUT TO SEWER | REAR DOWNSPOUT SECTION HANGING 3' ABOVE THE GRADE. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: ENTRY REFUSED BY 2ND FLOOR TENANT. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT REAR ENCLOSED PORCH, VERIFY COMPLAINT ON NO GAS, NO HEAT AND NO HOT WATER. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. MISSING OWNER'S I.D. SIGN. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/ OWNERS ID SIGN- MISSING. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT EXTERIOR ENTRY DOOR- ROTTING, WITH MISSING SECTIONS. REAR EXTERIOR EXIT DOOR- TOO LARGE FOR FRAME, DOESNT CLOSE. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION/ SERVICE WALK- BROKEN, AND SPALLING CONCRETE. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT, AND REAR YARD GATES- MISSING. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR YARD FENCE- BROKEN, WITH MISSING SECTIONS. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
CONNECT DOWNSPOUT TO SEWER | WEST ELEVATION/ DOWNSPOUT- NOT CONNECTED TO SEWER WITH 4 FOOT SECTION MISSING FROM GRADE. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | WEST ELEVATION/ GUTTER- RUSTING. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | WEST ELEVATION/ EAVES- ROTTING, WITH SOME SECTIONS MISSING. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD/ ACCUMULATION OF DEBRIS- BUCKETS, USED CONTAINERS, USED LUMBER, CONCRETE CHUNKS, PILLOWS, CANS, AND TARPS. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED PORCH, AND 6642S/ 1ST FLOOR APARTMENT- MISSING SMOKE DETECTORS. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | DANGEROUS, AND HAZARDOUS REAR ENCLOSED PORCH/ 2ND FLOOR STAIR HEADER BEAM- ROTTING, WEAK, AND SAGGING. COLUMNS- SCABBED, AND ERECTED ON CONCRETE BLOCKS, RESTING ON RETAINING WALL. STRINGERS- BROKEN, AND SCABBED. UNDERSIZED 2X10 DECK JOISTS SPAN 15 FEET 8 INCHES LONG. RAILING SECTIONS- LOOSE, PULLING, WITH OPENINGS FROM 18 TO 24 INCHES WIDE. UNEVEN RISER HEIGHTS RANGE FROM 7 TO 8+1/2 INCHES HIGH. ROOF SECTION- ROTTING, WEAK, AND SAGGING. PLANS, AND PERMIT REQUIRED TO REPLACE DANGEROUS, AND HAZARDOUS REAR ENCLOSED PORCH. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 6642S./ 1ST FLOOR APARTMENT/ FRONT BEDROOM- OUTLETS OUT OF SERVICE. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | 6642S./ 1ST FLOOR APARTMENT/ FRONT BEDROOM, AND BATHROOM/ OUTLETS, AND SWITCHES- COVERS MISSING | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | 6642S./ 1ST FLOOR APARTMENT- NO ACCESS TO ELECTRIC SERVICE PANEL. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 6642S./ 1ST FLOOR APARTMENT/ BATHROOM CEILING-WEAK,AND SAGGING PLASTER. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | 6642S./ 1ST FLOOR APARTMENT/ BATHROOM AROUND TUB- MILDEW BUILDUP. REAR BEDROOM CLOSET/ WALLS- PEELING PAINT. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | 6642S./ 1ST FLOOR APARTMENT- RODENT INFESTATION. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | 6642S./ 1ST FLOOR APARTMENT/ FRONT ENTRY DOOR- TOO SMALL FOR FRAME, WITH GAPS UP TO 1 INCH WIDE. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALKS - LOOSE AND BROKEN CONCRETE. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THROUGH 2011. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
ROACHES | 6642S./ 1ST FLOOR APARTMENT- ROACH INFESTATION. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION/ 1ST FLOOR WINDOW- BROKEN PANE. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 6642S./ 1ST FLOOR APARTMENT/ BATHROOM CEILING- LEAKING WATER. | 6642 S TALMAN AVE | COMPLAINT | FAILED | View |