The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | SR 07 01597436/ SR 07 01597453 NO OWNERSHIP POSTED | 610 W 61ST PL | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT GATE KEY LOCK DOUBLE KEY LOCK | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH LEDGER NO BOLTS, AT 2ND MISSING PICKETS, IMPROPER BEAM TO COLUMNS CONNECTION IMPROPER LAP CONNECTION, OBTAIN PERMITS NEEDED FOR REPAIRS, NO PERMIT ON FILE FOR FRONT PORCH | 610 W 61ST PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK BROKEN | 610 W 61ST PL | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT FOR 6 FOOT WOODEN FENCE AT REAR | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH IMPROPER BEAM TO COLUMN CONNECTIONS | 610 W 61ST PL | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT MISSING GUARD RAILING | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF LEAKS, CAUSING WATER DAMAGE TO 2ND FLOOR CEILING. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | INPROPER STAIR DESIGN, AT 2ND FLOOR TOP 3 STEPS PIECED TOGETHER, LOW RAILS AND MISSING PICKETS, CONNECTIONS ARE NOT BOLTED; STRINGERS, RAILS AND COLUMNS. FOUNDATION IS UNKOWN. STAIRS HAVE A 1X6 TRIMED TO FIT IN GAP BETWEEN STAIRS AND WALL. SUBMIT PLANS AND OBTAIN PERMIT. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | PICKETS MISSING AT 2ND FLOOR.RAILS UNDER 42". RAILS, STRINGERS BEAM AND COLUMNS HAVE NO BOLTED CONNECTIONS. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR FENCE | 6 FOOT FENCE IS NOT SECURE SECTIONS ARE LEANING, ERECTED SUPERFICIALLY. OBTAIN PERMIT AND SECURE FENCE. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | KITCHEN CEILING HAS A LARGE HOLE, FROM WATER DAMAGE. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | HOLLOW CORE BEDROOM DOOR HAS HOLES. | 610 W 61ST PL | COMPLAINT | FAILED | View |
MICE/RODENTS | MICE IN UNIT. | 610 W 61ST PL | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | FLOOR TILES ARE CRACKED AND BROKEN. | 610 W 61ST PL | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | BEDROOM LIGHT IS NOT WORKING. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR ROOF | EVIDENCE OF WATER LEAKING IN 2ND FLOOR UNIT. FRONT ROOF AT SOUTH OVER PORCH HAS BEEN COVERED WITH A TARP. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | IMPROPER STAIR DESIGN; 2ND FLOOR TOP STEPS ARE INCONSISTANT AND POORLY SECURED, RAILS ARE WEAK AND TOO LOW, ALL STRUCTUAL CONNECTIONS ARE WITHOUT BOLTS AND HARDWARE, 4X4 COLUMNS SUPPORT THE ENTIRE STAIRSYSTEM. PLANS AND PERMIT REQUIRED TO REPLACE THIS STRUCTURE. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH SYSTEM; MISSING REQUIRED HARDWARE AT ALL STRUCTUAL AREAS; PLANS AND PERMIT REQUIRED FOR REQUESTED UPGRADES TO FRONT PORCH SYSTEM. | 610 W 61ST PL | COMPLAINT | FAILED | View |
REPAIR FLOOR | BASEMENT FLOOR AREA AT CENTER FRONT CORRIDOR HAS A SOFT SPOT AND ROTTED MATERIAL UNDER THE CARPET. | 610 W 61ST PL | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REQUIRED APPROVED PLANS AND PERMIT FOR ALL WORK THAT HAS BEEN DONE. ISSUED PERMIT B20316546 ISSUED ON 7-11-03 SHOWS NO FINAL INSPECTIONS FROM ANY BUREAU; NO FINAL OCCUPANCY. | 610 W 61ST PL | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT GATE LOCKED | 610 W 61ST PL | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR NO ENTRY | 610 W 61ST PL | COMPLAINT | FAILED | View |