Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 12:07 PM
PIN: 13352130130000
Property Address: 3507 W LYNDALE ST
City - Zip: CHICAGO - 60647
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71180
2023 Tax District: 71163
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# NO OWNER POSTING 3507 W LYNDALE ST COMPLAINT PASSED View
WORK NOT ALLOWED STEEL PICKET FENCE OVER 5 FEET, REDUCE HEIGHT, REMOVE, OR OBTAIN PERMIT. 3507 W LYNDALE ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM FRONT WOOD FRAMED PORCH HAS BROKEN CONCRETE FOOTINGS. REAR WOOD FRAMED PORCH HAS UNDERSIZED GUARD RAILS ON 1ST FLOOR. LOOSE DECK BOARDS, SPLIT TREADS, UNEVEN TREAD HEIGHTS, AND UNKNOWN FOOTINGS. OBTAIN REPAIR PERMIT. 3507 W LYNDALE ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID MISSING CO DETECTORS. 1ST FLOOR. 3507 W LYNDALE ST COMPLAINT PASSED View
REPAIR EXTERIOR WALL CLOSET WHERE HOT WATER TANK IS HAS BROKEN PLASTER ON THE WALL. 3507 W LYNDALE ST COMPLAINT PASSED View
SOIL/WASTE,VENT PIPE MATRL PVC SOIL PIPE FOR DOWNSPOUT SOUTHWEST ELEVATION AND FLOOR DRAIN SOUTH ELEVATION IN BACKYARD. 3507 W LYNDALE ST COMPLAINT PASSED View
VENT SYSTEM TO PRVNT BACK PRES NO VENT FOR KITCHEN WASTE 1ST FLOOR 3507 W LYNDALE ST COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE FLEXIBLE SUPPLIES TO LAV, TOILET, AND WATER HEATER 1ST FLOOR UNIT. 3507 W LYNDALE ST COMPLAINT PASSED View
PROVIDE NO SAFE PAN UNDER WATER HEATER 1ST FLOOR 18-29-504.8 3507 W LYNDALE ST COMPLAINT PASSED View
OBTN PERMIT FOR PLUMBING WORK PERMIT FOR VIOLATIONS 3507 W LYNDALE ST COMPLAINT PASSED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN LICENSED PLUMBER TO DO PLUMBING WORK 3507 W LYNDALE ST COMPLAINT PASSED View
CORRODED CONDUIT & EQUIP REPLACE DEFECTIVE CONDUITS AND RUSTED BOX ON EXTERIOR. 3507 W LYNDALE ST COMPLAINT PASSED View
INSTALL ILLUMINATION INSTALL ILLUMINATION ON EXTERIOR OF BLDG AT FRONT AND REAR. 3507 W LYNDALE ST COMPLAINT PASSED View
PROVIDE NO FLOOR DRAIN FOR WATER HEATER 1ST FLOOR 18-29-412.4 3507 W LYNDALE ST COMPLAINT PASSED View