The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | BUILDING REAR- 3 STORY WOOD PORCH, COLUMNS ARE FIRE CUT FOR BEAMS WITH ADJACENT RIM JOISTS CUT. 36" HIGH GUARD RAILS, NOT PROPERLY ATTACHED TO BRICK WALLS. COLUMNS ERECTED ON LIMESTONES WITH FOUNDATION STATUS UNKNOWN. 2X8X12' FLOOR JOIST. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE, UNVERIFIED DETECTORS. NO ENTRY TO PORCH STAIRS. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN NOT POSTED. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | BSMT. UNIT: FRONT ENTRY DOOR ONLY 30" WIDE WITH 5' OVERHEAD. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BSMT.UNIT: FLOOR TO CEILING HEIGHT ONLY 5'-10" IN MOST AREAS. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
PAINT SHUT | BSMT. UNIT: INADEQUATE NATURAL VENTILATIONS - WINDOW GLASS BLOCK INSTALLED WITH INSUFICIENT OPENINGS LESS THAN 4% OF FLOOR AREA. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES ( INCLUDING PLUMBING AND ELECTRIC ) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | THREE (3) FORCED AIR FURNACES INSTALLED WITHOUT PERMIT PREVIOUSLY A CENTRAL BOILER SERVICED ENTIRE BUILDING. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | NO VIEWING DEVICES 1 THRU 3RD. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT CONCRETE STEPS CAVED IN.RISER HEIGHTS UNEVEN | 7701 S UNION AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR PORCH ENCLOSED WITHOUT PLANS AND PERMITS | 7701 S UNION AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR ENCLOSED PORCH ROTTED COLUMNS, SISTERED WITH 2X4"AT GRADE. NO VISIBLE FOOTINFS. GRADE TO 3RD ROTTED AND LOOSE WINDER TREADS. ROTTED, BUCKLED DECKING AT EACH LANDING. BEAM TO COLUMN CONNECTION PULLING AWAY EXPOSED PORCH AREA:ROTTED BOWED COLUMN AT NORTH EAST CORNER. ALL LANDINGS HAVE ROTTED BUCKLED LANDINGS.GUARDRAILS MISSING ALL LEVELS.2X6 JOIST SPAN 22" PLANS AND PERMITS REQUIRED TO REPLACE DANGEROUS PORCH. GUARDRAILS 24'HIGH ON ALL LEVELS | 7701 S UNION AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT AND REAR SERVICE WALKS CONCRETE CRACKED | 7701 S UNION AVE | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | 7701 S UNION AVE | COMPLAINT | FAILED | View | |
REPAIR/REBUILD GARAGE OR SHED | REAR GARAGE - GUTTERS DAMAGED - ROTTED EAVES - FRONT WOOD EXTENSION ROOF IS SINKING. | 7701 S UNION AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTORS IN FRONT STAIRWAY AND ENCLOSED PORCH | 7701 S UNION AVE | COMPLAINT | FAILED | View |