Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR DOOR HARDWARE | 1ST FLOOR FRONT ENTRY DOOR DEAD BOLT LOCK-MISSING THUMB LATCH. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
PARAPET | EAST PARAPET WALL / WASHED OUT MORTAR. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION AT GRADE-WASHED OUT MORTAR,SPALLING BRICKS.REAR ENCLOSED PORCH SIDING-ROTTED WOOD,BUCKLING AND PULLING AWAY FORM BUILDING.PERMIT REQUIRED FOR REPAIRS. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
REPAIR BAY WALL | EAST ELEVATION / BASEMENT PASSAGE WAY CEILING-MISSING DRYWALL. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT 1 STORY WOODEN PORCH.4X4 COLUMNS SET IN CONCRETE,FOUNDATION STATUS UNKNOWN.LEDGER BEAM ONLY FACE NAILED TO BUILDING.2X6 JOISTS SPAN 9 FEET 3 INCHES.STRINGERS ARE ROTTED,TREADS ARE ROTTED AND LOOSE.DECKING IS ROTTED AND SPLITTING.METAL RAILINGS ARE ONLY 32 INCHES IN HEIGHT,LOOSE AND PULLING.PLANS AND PERMIT REQUIRED FOR REPAIRS. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
REPAIR DOWNSPOUT | FRONT PORCH ROOF GUTTER-MISSING DOWNSPOUT. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | REAR 1 STORY WOODEN EXTERIOR PORCH.4X4 SET ON SIDEWALK,FOUNDATION STATUS UNKNOWN.STRINGERS ROTTED AND PULLING AWAY FROM SUPPORTS,DANGEROUS CONDITION EXISTS,TREADS ARE ROTTED AND LOOSE.RAILINGS ONLY 36 INCHES,LOOSE AND PULLING. REAR 2 STORY ENCLOSED WOOD PORCH.COLUMNS ARE ROTTED,FOUNDATION STATUS UNKNOWN.4X6 BEAMS SPAN 7 FOOT 6 INCHES,ROTTED AND PULLING AWAY FROM COLUMNS AT FIRE CUTS.2X6 JOISTS SPAN 12 FOOT.STRINGERS ROTTED AND ONLY FACE NAILED TO SUPPORTS,RISERS NOT UNIFORM HEIGHT VARYING FROM 3 INCHES TO 9 INCHES,TREADS ARE WEAK AND LOOSE.PORCH WAS POSTED DANGEROUS AND HAZARDOUS AND CAUTION TAPED OFF.PLANS AND PERMIT REQUIRED TO REPLACE PORCH SYSTEM. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS AND REAR ENCLOSED PORCH-MISSING SMOKE DETECTORS. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
HEAT UNIT ADEQUATELY | 2ND FLOOR APT - ROOM TEMPERATURES WERE 61-66 DEGREES AT TIME OF INSPECTION; INSUFFICIENT HEAT PROVIDED | 3930 W POLK ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 2ND FLOOR APT - THERMOSTAT SET TO 74 DEGREES, BUT ROOM TEMPERATURES WERE 61-66 DEGREES AT TIME OF INSPECTION. | 3930 W POLK ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR APT - CARBON MONOXIDE DETECTOR - MISSING | 3930 W POLK ST | COMPLAINT | FAILED | View |
RATS | REAR ENCLOSED PORCH-RAT DROPPINGS THROUGHOUT. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / NO OWNER'S ID SIGN POSTED. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
ROACHES | 1ST FLOOR APARTMENT KITCHEN-ROACHES. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | REAR YARD / JUNK AND REFUSE ACCUMALATING. | 3930 W POLK ST | COMPLAINT | CLOSED | View |
REPAIR CORNICE | FRONT ELEVATION / CORNICE-RUSTED | 3930 W POLK ST | COMPLAINT | CLOSED | View |