Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE COMPLETED PERMIT INSP. | 1807 W 47TH ST | COMPLAINT | FAILED | View | |
PROVIDE | HEAT REQUIRED MAINTAIN AT LEAST 68 DEGREE'S IN FACTORIES AND WORK SHOPS OR OTHER PLACES OF EMPLOYMENT | 1807 W 47TH ST | COMPLAINT | FAILED | View |
PUBLIC NUISANCE 7-28-060 CONDITION DETRIMENTAL TO HEALTH-PUBLIC NUISANCE VIOLATION 7-28-060 NUISANCE IN CONNECTION WITH BUSINESS | 1807 W 47TH ST | COMPLAINT | FAILED | View | |
NO POSTED ADDRESS | ADDRESS #IS 2" - 6" REQUIRED | 1807 W 47TH ST | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD JUNK AND REFUSE ACCUMULATION | 1807 W 47TH ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR GRADE TO BASEMENT MISSING GUARDRAILS | 1807 W 47TH ST | PERIODIC | FAILED | View |
NO POSTED ADDRESS | ADDRESS #IS 2" - 6" REQUIRED | 1807 W 47TH ST | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD JUNK AND REFUSE ACCUMULATION | 1807 W 47TH ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL-MISSING AT PERIMETER OF STAIRWAY OPENING. PERMIT REQUIRED FOR REPAIRS. | 1807 W 47TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR NO ENTRY FOR ANNUAL AND REAR STAIR SYSTEM INSPECTION | 1807 W 47TH ST | PERIODIC | FAILED | View |
REPAIR LINTELS | WINDOW LINTELS-ERODED MORTAR; OPEN JOINTS. | 1807 W 47TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRS-4X4 COLUMNS ARE ONLY SET IN FRACTURED CONCRETE BASES THAT ARE ONLY SET ON TOP OF THE SERVICE WALK. FLIGHT OF STAIRS WITH 26 RISERS WITHOUT A MID-LANDING; FLIGHT SHIFTS FROM SIDE TO SIDE UPON LOAD. OVERCUT, SCABBED STRINGERS. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER AT THE CONNECTIONS. MISSING GUARDRAIL AT ROOFTOP PERIMETER. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 1807 W 47TH ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR GRADE TO BASEMENT MISSING GUARDRAILS | 1807 W 47TH ST | PERIODIC | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | STRUCTURAL MEMBERS-(NORTH) NEW FLOOR JOISTS ARE SUPPORTED UP WITH 4X6 BEAMS, SET ON TOP AND ONLY TOE NAILED INTO THE ROTTED 4X6 COLUMNS. (S/E) MAIN BEAM IS SET ON TOP AND ONLY TOE NAILED TO THE 4X4 COLUMNS SET ON CONCRETE PADS. DANGEROUS AND HAZARDOUS CONDITIONS. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 1807 W 47TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRS-LANDING IS SUPPORTED UP WITH ROTTED 4X6 COLUMNS, THAT ARE TOE NAILED INTO 2X6 MEMBERS, THAT ARE TOE NAILED TO THE BOTTOM OF THE FLOOR JOISTS. STRINGERS ARE ONLY SUPPORTED UP WITH 2X4 MEMBERS IN LIEU OF COLUMNS. FLIGHT SHIFTS FROM SIDE TO SIDE UPON LOAD. MISSING HANDRAILS. WORN TREADS; NAILS ARE PROTRUDING OUT. PLANS AND PERMIT REQUIRED FOR REPLACEMENT | 1807 W 47TH ST | PERIODIC | FAILED | View |
NO POSTED ADDRESS | ADDRESS #IS 2" - 6" REQUIRED | 1807 W 47TH ST | PERIODIC | PASSED | View |
DEBRIS, EXCESSIVE | REAR YARD JUNK AND REFUSE ACCUMULATION | 1807 W 47TH ST | PERIODIC | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL-MISSING AT PERIMETER OF STAIRWAY OPENING. PERMIT REQUIRED FOR REPAIRS. | 1807 W 47TH ST | PERIODIC | PASSED | View |
REPAIR LINTELS | WINDOW LINTELS-ERODED MORTAR; OPEN JOINTS. | 1807 W 47TH ST | PERIODIC | PASSED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRS-4X4 COLUMNS ARE ONLY SET IN FRACTURED CONCRETE BASES THAT ARE ONLY SET ON TOP OF THE SERVICE WALK. FLIGHT OF STAIRS WITH 26 RISERS WITHOUT A MID-LANDING; FLIGHT SHIFTS FROM SIDE TO SIDE UPON LOAD. OVERCUT, SCABBED STRINGERS. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER AT THE CONNECTIONS. MISSING GUARDRAIL AT ROOFTOP PERIMETER. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 1807 W 47TH ST | PERIODIC | PASSED | View |
STRUCTURAL MEMBER, PIER BLOCK | STRUCTURAL MEMBERS-(NORTH) NEW FLOOR JOISTS ARE SUPPORTED UP WITH 4X6 BEAMS, SET ON TOP AND ONLY TOE NAILED INTO THE ROTTED 4X6 COLUMNS. (S/E) MAIN BEAM IS SET ON TOP AND ONLY TOE NAILED TO THE 4X4 COLUMNS SET ON CONCRETE PADS. DANGEROUS AND HAZARDOUS CONDITIONS. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 1807 W 47TH ST | PERIODIC | PASSED | View |
REPAIR EXTERIOR STAIR | REAR GRADE TO 2ND COLUMNS TO SMALL NOT SET ON PROPER FOOTINGS, LOOSE TREADS ENTIRE STAIR SYSTEM SWAYS SIDE TO SIDE | 1807 W 47TH ST | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTSIN PERMIT FOR REPAIRS TO REAR STAIR SYSTEM | 1807 W 47TH ST | PERIODIC | FAILED | View |
ILLUMINATE EXIT AREAS | REAR STAIRS NO LIGHTS | 1807 W 47TH ST | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | 2ND FLOOR IS VACANT & LOCKED | 1807 W 47TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR LOOSE & BUCKLED CEILING TILES | 1807 W 47TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR NO ENTRY FOR ANNUAL AND REAR STAIR SYSTEM INSPECTION | 1807 W 47TH ST | PERIODIC | FAILED | View |
EXPOSED WIRING | EXPOSED WIRING THROUGHOUT. | 1807 W 47TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRS-LANDING IS SUPPORTED UP WITH ROTTED 4X6 COLUMNS, THAT ARE TOE NAILED INTO 2X6 MEMBERS, THAT ARE TOE NAILED TO THE BOTTOM OF THE FLOOR JOISTS. STRINGERS ARE ONLY SUPPORTED UP WITH 2X4 MEMBERS IN LIEU OF COLUMNS. FLIGHT SHIFTS FROM SIDE TO SIDE UPON LOAD. MISSING HANDRAILS. WORN TREADS; NAILS ARE PROTRUDING OUT. PLANS AND PERMIT REQUIRED FOR REPLACEMENT | 1807 W 47TH ST | PERIODIC | PASSED | View |
EXPOSED WIRING | EXPOSED WIRING THROUGHOUT. | 1807 W 47TH ST | PERIODIC | PASSED | View |