The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | POST ID | 3253 W LELAND AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | BASEMENT, REAR DOOR: KNOB LOOSE | 3253 W LELAND AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH WALK: OPEN MORTAR JOINTS | 3253 W LELAND AVE | PERIODIC | FAILED | View |
PARAPET & COPING | NORTH PARAPET: OPEN MORTAR JOINTS | 3253 W LELAND AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH: ANCHOR COLUMNS, STRINGERS, BEAM; EXCESS JOIST SPAN; MISSING JOIST HANGERS; 36" RAIL | 3253 W LELAND AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | PERMIT TO REPAIR PORCH | 3253 W LELAND AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | GARAGE: WASHED OUT MORTAR | 3253 W LELAND AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | NORTH SILLS: OPEN MORTAR JOINTS | 3253 W LELAND AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR | 3253 W LELAND AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2003 THRU 2008 | 3253 W LELAND AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS TO BASEMENT: MISSSING HANDRAIL | 3253 W LELAND AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR STAIRS TO BASEMENT/GUARD RAIL: TOO LOW WITH LADDER TYPE PICKETS | 3253 W LELAND AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | TUCK POINT ERODED LOCATIONS-SILL JOINTS,PARAPET STONE JOINTS, WINDOW LINTELS | 3253 W LELAND AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH WITH THE FOLLOWING DEFECTS-DEFICIENT CONDITIONS. (1) SEVERELY ROTTED STRINGER SECTIONS, MOST NETICEABLE AT ANCHOR AREAS, LOOSE SECTION AT GUARD RAILING ANCHOR AREAS, LOOSE SECTION AT GRADE, IMPROPER HEIGHT AND LOOSE AND MISSING PICKETS (3) ROTTING AND CURLING FLOOR LANDING BOARDS. (4) POSTS AT CRITICAL ANCHOR AREAS 4X4 NOT 6X6 (5) BEAM TO COLUMN CONNECTION WITH-OUT TIE STRAPS. (6) ROTTING AND DRY-OUT STAIR TREADS (5) OBTAIN PERMIT TO UPGRADE -REPAIR | 3253 W LELAND AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /NO RESPONSE. UNABLE TO VERIFY DETECTORS AND CONDITIONS. | 3253 W LELAND AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR 3-STORY WOOD PORCH - NUTS MISSING ON BOLTS @ GRADE. | 3253 W LELAND AVE | PERIODIC | FAILED | View |