The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING OWNERS SIGN NOT POSTED | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
NO KEY TO USE EXIT DOOR | EAST ELEVATION-DOUBLE KEY LOCK ON FRONT GATE | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EAST ELEVATIONS-SIDING MISSING AT FRONT PORCH,NORTHSOUTH,AND WEST ELEVATIONS SIDING MISSING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION-FRONT STAIRS-STRINGERS ATTACHED LANDING WITH ONLY 2X4 USED AS A COLUMN;BOLTS MISSING AT STRINGER RAILS,RAIL HEIGHT ONLY 31 3/8",DECKBOARDS BUCKLING;BOLTS MISSING AT STRINGER RAILS,HANDRAILS MISSING FROM GRADE TO BASEMENT,PERMIT REQUIRED TO REPAIR REAR STAIRS FROM GRADE TO 1ST FLOOR | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW SASH | SOUTH,WEST ELEVATIONS WINDOW SASHES ROTTING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | SOUTH,WEST ELEVATIONS WINDOW FRAMES ROTTING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPUTTY WINDOW PANES | SOUTH,WEST ELEVATIONS WINDOW TRIM ROTTING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPAIR WINDOW SILLS | SOUTH,WEST ELEVATIONS WINDOW SILLS ROTTING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST ELEVATIONS GUARDRAILS MISSING AT GRADE FOR BASEMENT AREAWAY | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPAIR FENCE | WEST ELEVATIONS TOP RAIL MISSING AT CHAIN LINK FENCE | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | WEST ELEVATIONS REAR GATE PADLOCKED;GATE AT REAR STAIRS PADLOCKED PREVENTING EXIT;REAR DOOR AT 1ST FLOOR LOCKED FROM OUTSIDE OBSTRUCTING EXIT;FIRE HAZARD | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
ADDITIONAL EXIT | BUILDING REAR EXIT DOOR AT 1ST FLOOR IS LOCKED FROM OUTSIDE AND GATE SURROUNDING REAR STAIRS IS PADLOCKED ALSO PREVENTING EXIT | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION-1ST FLOOR WINDOW PANE CRACKED | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPAIR DOWNSPOUT | WEST ELEVATION-DOWNSPOUT RUSTING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
PROVIDE DEADLOCK FOR ENTRANCE | WEST ELEVATION-DEADBOLT LOCK MISSING AT 1ST FLOOR REAR EXIT DOOR | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | WEST ELEVATION-1ST FLOOR-REAR DOOR IS ROTTING;HOLES | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | WEST ELEVATION-ENCLOSED REAR PORCH-6X6 BEAMS AT 2ND FLOOR ROTTING;2X8 JOISTS SPAN 12'-6",2ND FLOOR DECK LEANING,RAIL HEIGHT IS 31",TREADS,DECKBOARDS ARE WORN,DILAPIDATED;PICKETS MISSING;BOLTS MISSING AT STRINGERS RAILS;STEEL ANGLE BRACKETS MISSING AT BEAM (COLUMN CONNECTIONS) PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | INTERIOR STAIRWAY SMOKE DETECTOR MISSING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
SELF-CLOSE CLASS B FIRE DOOR | EAST ELEVATION 1ST FLOOR CLOSER MISSING ON FRONT ENTRY DOOR | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | ATTIC-REMOVE ALL PARTITIONS AND FIXTURES (PLUMBING AND ELECTRICAL) INSTALLED IN THE ATIC WITHOUT PERMIT | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | ATTIC-SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
FLAKY INTERIOR PAINT | ATTIC-PEELING PAINT THRU OUT APARTMENT | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
INT WALL/CEILING CHIP PLASTER | ATTIC-CRACKED PLASTER AT BEDROOM CEILING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | ATTIC-CARBON MONOXIDE DETECTOR MISSING | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
HEAT UNIT ADEQUATELY | REAR COACH HOUSE 2ND FLOOR 65DEGREES ALSO GAS SERVICE SHUT OFF AT TIME OF INSPECTION. | 1646 N KIMBALL AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | REAR COACH HOUSE 2ND FLOR SPACE HEATER NOT IN SERVICE AT TIME OF INSPECTION. | 1646 N KIMBALL AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | REAR COACH HOUSE 2ND FLOOR CARBON MONOXIDE DETECTOR MISSING. | 1646 N KIMBALL AVE | COMPLAINT | FAILED | View |
OPEN | 1646 N KIMBALL AVE | PERMIT | FAILED | View | |
REPAIR EAVES | ALL ELVATIONS-ROTTING TRIM AT EAVES | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
INSTALL DOOR VIEWING DEVICE | 2ND FLOOR ATTIC-VIEWING DEVICE MISSING AT FRONT ENTRY DOOR | 1646 N KIMBALL AVE | COMPLAINT | CLOSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | REAR COACH HOUSE HOUSE 2ND FLOOR HOT WATER (64DEGREES) ALSO GAS SHUT OFF AT TIME OF INSPECTION. | 1646 N KIMBALL AVE | COMPLAINT | FAILED | View |