The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROVIDE | 3625 PROVIDE FLOOR DRAIN FOR WATER HEATER, SOUTHWEST ELEVATION. (18-29-412.4) | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 3625 PROVIDE LAVATORY FOR TOILET SOUTHEAST ELEVATION. (13-196-360) | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | SOUTH COURTYARD HAS DEBRIS, WOOD, GARBAGE, SHRUBS. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 3625 EAST MARKED EXIT DOOR AT 30" WHICH LEADS TO A COURTYARD THAT HAS A PADLOCKED SECURITY DOOR. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH CHIMNEY HAS LOOSE AND MISSING MORTAR WITH SPALLING BRICK OVER PUBLIC WALKWAY CAUSING A DANGEROUS AND HAZARDOUS CONDITION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 3625 REAR HEATING UNIT HAS FLUE PIPE HANGING FROM A WIRE AND EXHAUST TO OUTSIDE THROUGH A WINDOW. (18-28-801.2) | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 3625 MISSING CARBON MONOXIDE DETECTOR. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH WALL HAS LOOSE AND MISSING MORTAR. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 3625 REAR FLOOR IS ROTTED WITH DEFLECTION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | 3625 ELEVATED PLATFORM FOR EMPLOYEE COUNTER AREA REQUIRES PROPER FIRE BLOCKING AND CONSTRUCTED WITHOUT PERMITS. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 3625 SOUTH STAIRS GRADE TO OFFICE HAS INCORRECT TREADS AND RISERS, RISE AT 10 INCHES, RUN AT 9 INCHES. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | 3625 NO PERMIT FOR 3-COMPARTMENT SINK, HAND SINK, LAUNDRY TUB, SOUTHWEST ELEVATION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | 3625 REMOVE 1-1/2 PVC FOR LAUNDRY TUB AND HAND SINK, SOUTHWEST ELEVATION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | 3625 REMOVE FLEXIBLE SUPPLIES TO HAND SINK AND LAUNDRY TUB, SOUTHWEST ELEVATION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE TOILET SEAT | 3625 PROVIDE OPEN FRONT TOILET SEAT, TOILET SOUTHEAST ELEVATION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | 3625 REMOVE FLEXIBLE SUPPLIES TO TOILET, SOUTHEAST ELEVATION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN LICENSED PLUMBER TO DO PLUMBING WORK. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | 3625 REMOVE ALL UNAPPROVED EXTENSION CORDS THROUGHOUT COMMERCIAL SPACE. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | 3625 REMOVE EXPOSED WIRING TO LIGHT FIXTURES. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 3625 REPLACE DEFECTIVE LIGHT FIXTURE IN BATHROOM. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | 3625 REPLACE DEFECTIVE POWER SERVICE IMPROPERLY SIZED AND VANDALIZED. REMOVE WRENCHES USED AS JUMPERS TO BYPASS SMART METER - COM-ED DISCONNECT. RELOCATE METER TO REAR OF BUILDING. INSTALL MINIMUM 200 AMP SERVICE. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View | |
SOIL/WASTE,VENT PIPE MATRL | 3625 REMOVE 1-1/2 PVC WASTE PIPE FOR 3-COMPARTMENT SINK, SOUTHWEST ELEVATION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 3625 GREASE TRAP FOR 3-COMPARTMENT SINK TOO SMALL, SOUTHWEST ELEVATION. (18-29-1003.3.6) | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | 3625 PROVIDE PROPER CLEARANCE IN FRONT OF WATER HEATER. (18-29-502.6) | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | 3625 REMOVE EXPOSED WIRING AT ALL OPEN JUNCTION BOXES. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | PROVIDE A CANOPY FOR SOUTH CHIMNEY. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | 3625 INSTALL COVERS TO OPEN JUNCTION BOXES. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |
VENT SYSTEM TO PRVNT BACK PRES | 3625 NO VENTS ON LAUNDRY TUB OR HAND SINK, SOUTHWEST ELEVATION. | 3625 W CHICAGO AVE | COMPLAINT | FAILED | View |