The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FILE BLDG REGISTRATION | 07-00194141/07-00180352 REGISTER BUILDING 2006-07. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO SIGN POSTED. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH STAIRS TO BASEMENT - NO RAILINGS AND GUARD. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BASEMENT DEFECTIVE. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
UNDERSIDE STAIR 1HR FIRE RES | BASEMENT UNDER NORTH STAIRS - EXPOSED FRAMING. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | EAST BREEZEWAY - PLYWOOD CEILING. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
SYSTEM III | INSTALL SYSTEM 3 EMERGENCY SERVICE | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
TENANT ACCESS TO SERVICE | PROVIDE ACCESS TO PUBLIC PANELS | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
REPAIR FENCE | REAR WOOD FENCE DILAPIDATED, FALLING AND LOOSE SECTIONS. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT ENTRY MARBLE WALL PANELS LOOSE AND BROKEN SECTIONS. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
CHIMNEY HEIGHT | CHIMNEY - BELOW ROOF LINE | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
CHIMNEY | CENTER CHIMNEY - FRACTURES WITH WEEDS GROWING FROM THE TOP. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEYS - MISSING CAPS | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
PARAPET | EAST PARAPET - FRACTURES , LOOSE BRICKS AND MORTAR. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | UNIT 4829 3 NO HEAT. FURNACE NOT OPERATING. 62 DEGREES LIVING ROOM, 64 DEGREES DINING ROOM, 56 DEGREES FRONT BED ROOM. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | FURNACE NOT OPERATING 4829 UNIT 3. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CO DETECTOR UNIT 4829 3, 4931 UNIT 3. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTORS NOT OPERATING 4829 UNIT 3, 4831 UNIT 3, TOP OF REAR ENCLOSED PORCH. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT ELEVATION/BALCONY LINTELS-RUSTED. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION/EAST EXTERIOR STAIRS,GRADE TO BASEMENT-CRACKED AND BUCKLING CONCRETE TREADS.(TRIP HAZARD). | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
CONNECT DOWNSPOUT TO SEWER | REAR ELEVATION/DOWNSPOUT MISSING SECTION AT GRADE. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | INTERIOR STAIRS/EXIT SIGN OUT OF ORDER AT TIME OF INSPECTION-NOT ILLUMINATED. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | INTERIOR STAIRS/EMERGENCY LIGHTING-OUT OF SERVICE AT TIME OF INSPECTION WITH LOW BATTERY. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR STAIRS/SMOKE DETECTOR OUT OF SERVICE AT TIME OF INSPECTION-WITH LOW BATTERY. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | FRONT ELEVATION/WEST DOWNSPOUT-LOOSE AND HANGING. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD/3 ABANDON AUTO'S. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR ELEVATION/EXTERIOR PORCH LANDINGS-JUNK AND REFUSE ACCUMALATING. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | REAR ELEVATION/2ND FLOOR EXTERIOR PORCH, WEST ELEVATION-OUTLET MISSING COVER-EXPOSED WIRES. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR ELEVATION/2ND FLOOR WINDOW-BOARDED-UP. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR ELEVATION/3RD FLOOR REAR PORCH AT WEST ELEVATION-DOG FOULING. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR PORCH/3DR FLOOR WEST-LOOSE AND BUCKLING DECK BOARD. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | REAR YARD/STANDING WATER IN TIRE TRACKS. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT ELEVATION/BALCONY LINTELS-RUSTED. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION/EAST EXTERIOR STAIRS,GRADE TO BASEMENT-CRACKED AND BUCKLING CONCRETE TREADS.(TRIP HAZARD). | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
CONNECT DOWNSPOUT TO SEWER | REAR ELEVATION/DOWNSPOUT MISSING SECTION AT GRADE. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
ROACHES | 4829 1E,4831 1W APARTMENTS-ROACHES. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
MAINTAIN EXIT SIGN ILLUMINATED | INTERIOR STAIRS/EXIT SIGN OUT OF ORDER AT TIME OF INSPECTION-NOT ILLUMINATED. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
RESTORE EXIT AND EM | INTERIOR STAIRS/EMERGENCY LIGHTING-OUT OF SERVICE AT TIME OF INSPECTION WITH LOW BATTERY. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR STAIRS/SMOKE DETECTOR OUT OF SERVICE AT TIME OF INSPECTION-WITH LOW BATTERY. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
REPAIR DOWNSPOUT | FRONT ELEVATION/WEST DOWNSPOUT-LOOSE AND HANGING. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | REAR YARD/3 ABANDON AUTO'S. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | REAR ELEVATION/EXTERIOR PORCH LANDINGS-JUNK AND REFUSE ACCUMALATING. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
EXPOSED WIRING | REAR ELEVATION/2ND FLOOR EXTERIOR PORCH, WEST ELEVATION-OUTLET MISSING COVER-EXPOSED WIRES. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR ELEVATION/2ND FLOOR WINDOW-BOARDED-UP. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
UNSANITARY CONDITIONS-ANIMALS | REAR ELEVATION/3RD FLOOR REAR PORCH AT WEST ELEVATION-DOG FOULING. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR PORCH/3DR FLOOR WEST-LOOSE AND BUCKLING DECK BOARD. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
GRADE AND DRAIN LOT | REAR YARD/STANDING WATER IN TIRE TRACKS. | 4829 W WEST END AVE | COMPLAINT | CLOSED | View |
REPAIR FENCE | REAR WOOD FENCE DILAPIDATED, FALLING AND LOOSE SECTIONS. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING PEELING PAINT | SKYLIGHT- WATER DAMAGE, FLAKING PAINT. FRONT ENTRY WALLS LOOSE AND FLAKING PAINT. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | BOTH SIDES REAR PORCH DANGEROUS AND HAZARDOUS CONDITIONS. PLY WOOD ENCLOSURE ROTTING, WATER DAMAGE, HOLES. DEFLECTING ENCLOSURE FRAMING AND PLYWOOD. GUARD RAILS 33'' IN HEIGHT. ROTTING, LOOSE AND DEFLECTING RAILS ANCHORED WITH NAILS ONLY. ROTTING AND LOOSE DECKING. WORN AND LOOSE TREADS. SEPARATING AND SINKING RISERS AND TREADS. SEVERELY PITCHED TREADS. 4X4 STRINGER COLUMNS EXTEND OVER 20' AND ALSO SUPPORT PORTION OF DECKS. STRINGERS, RAILS, POSTS, BEAMS, COLUMNS ALL ANCHORED WITH NAILS ONLY. 2X8 RIM JOISTS SPAN 12'. OTHER 2X8 JOISTS SPAN 11' 4''. OBTAIN COMPLETE PLAN AND PERMIT. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIRS FROM GROUND TO 1RST- ROTTING, SPLIT TREADS. ROTTING, LOOSE AND DEFLECTING RAILS. STRINGERS ANCHORED WITH NAILS ONLY. REAR EXTERIOR GANG WAY STAIRS- NO HAND RAILS. FRONT EXTERIOR BASEMENT STAIRS- NO HAND RAILS. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR ENCLOSED PORCH WITH CABLE WIRE EXTENDING FROM EXTERIOR ACROSS STAIRS TO BUILDING. TRIP HAZARD. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
1HR SEP-D.U. AND REST OF BLDG | GANG WAY CEILINGS COVERED WITH PLY WOOD. NO FIRE RATING. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REAR DOWNSPOUT DETACHED FROM GUTTER. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | REAR ENCLOSED PORCH SMOKE DETECTOR NOT OPERATING. 4832 #3 SWMOKE DETECTOR NOT OPERATING. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 4831 #3 NO CARBON MONOXIDE DETECTOR (FORCED AIR HEATING IN UNIT). | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | BOTH SIDES REAR PORCH DANGEROUS AND HAZARDOUS CONDITIONS. PLY WOOD ENCLOSURE ROTTING, WATER DAMAGE, HOLES. DEFLECTING ENCLOSURE FRAMING AND PLYWOOD. GUARD RAILS 33'' IN HEIGHT. ROTTING, LOOSE AND DEFLECTING RAILS ANCHORED WITH NAILS ONLY. ROTTING AND LOOSE DECKING. WORN AND LOOSE TREADS. SEPARATING AND SINKING RISERS AND TREADS. SEVERELY PITCHED TREADS. 4X4 STRINGER COLUMNS EXTEND OVER 20' AND ALSO SUPPORT PORTION OF DECKS. STRINGERS, RAILS, POSTS, BEAMS, COLUMNS ALL ANCHORED WITH NAILS ONLY. 2X8 RIM JOISTS SPAN 12'. OTHER 2X8 JOISTS SPAN 11' 4''. OBTAIN COMPLETE PLAN AND PERMIT. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 4831 #3 NO CARBON MONOXIDE DETECTOR (FORCED AIR HEATING IN UNIT). | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING PEELING PAINT | SKYLIGHT- WATER DAMAGE, FLAKING PAINT. FRONT ENTRY WALLS LOOSE AND FLAKING PAINT. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
1HR SEP-D.U. AND REST OF BLDG | GANG WAY CEILINGS COVERED WITH PLY WOOD. NO FIRE RATING. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | REAR PORCH DOORS ROTTING. FRONT DOORS NOT SECURING/ LOCKING. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR ENCLOSED PORCH WITH CABLE WIRE EXTENDING FROM EXTERIOR ACROSS STAIRS TO BUILDING. TRIP HAZARD. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | REAR ENCLOSED PORCH SMOKE DETECTOR NOT OPERATING. 4832 #3 SWMOKE DETECTOR NOT OPERATING. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
REPAIR DOWNSPOUT | REAR DOWNSPOUT DETACHED FROM GUTTER. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIRS FROM GROUND TO 1RST- ROTTING, SPLIT TREADS. ROTTING, LOOSE AND DEFLECTING RAILS. STRINGERS ANCHORED WITH NAILS ONLY. REAR EXTERIOR GANG WAY STAIRS- NO HAND RAILS. FRONT EXTERIOR BASEMENT STAIRS- NO HAND RAILS. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT ENTRY MARBLE WALL PANELS LOOSE AND BROKEN SECTIONS. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | REAR YARD AND GANG WAYS- GARBAGE AND DEBRIS. | 4829 W WEST END AVE | COMPLAINT | PASSED | View |
SYSTEM II | ALL LEVELS OF THE BUILDING | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD AND GANG WAYS- GARBAGE AND DEBRIS. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR PORCH DOORS ROTTING. FRONT DOORS NOT SECURING/ LOCKING. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |
ROACHES | 4829 1E,4831 1W APARTMENTS-ROACHES. | 4829 W WEST END AVE | COMPLAINT | FAILED | View |