The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PROVIDE GUARD RAIL 42 IN HIGH | MISSING GUARDRAIL AT REAR (WEST ELEVATION) BASEMENT RETAINING WALL DROP-OFF. | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | MISSING SMOKE DETECTOR AT INTERIOR STAIRS. | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 3 BEDROOM DWELLING UNIT IN BASEMENT /SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE TO THE ORIGINAL STATE.(14A-4-401.1 THRU 14A-4-404.22, 14A-4-410.1, 14A-4-411 THRU 14A-4-411.3, TABLE 14A-12-1204.2) | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | 3 BEDROOM DWELLING UNIT IN BASEMENT CEILING HEIGHT 74'' THROUGHOUT THE BASEMENT DWELLING UNIT. | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | WEST, NORTH ELEVATIONS - WEEDS THRU-OUT | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS TOENAILED TO 6X6 BEAMS AT 2ND FLOOR; 2X8 JOISTS SPAN 11'-8"; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS. REVISED PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | SOUTH, NORTH ELEVATIONS - PARAPET WALL - WASHED OUT MORTAR; COPING STONE CRACKED (SOUTH) | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - STEP FRACTURES, CRACKS BELOW 1ST FLOOR WINDOW AND AT SE CORNER | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | TRASH, DEBRIS, GARBAGE ON SIDE OF BUILDING | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, AND SPECIFICALLY BASEMENT FOR COMPLAINT OF MISSING SMOKE DETECTORS. UNVERIFIED DETECTORS AND CONDITIONS. | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | 3 BEDROOM DWELLING UNIT BASEMENTREMOVE ALL PARTITIONS AND FIXTURES (INCLUDING HVAC, PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMNET WITHOUT PERMIT.( SEC 14-3-301.1 ,14A4-413.1, 14A-4-413.8.1 | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY - CAP MISSING | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | MISSING VIEWING DEVICE AT BASEMENT, 1ST AND 2ND FLOOR DOOR. | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | 2 STORY MASONRY BUILDINGWEST ELEVATION / 2 STORY WOOD PORCH SYSTEM / GRADE TO 2ND FLOOR / ENTIRE PORCH MISSING HARDWARE, INADEQUATELY BUILT WITH RUSTING PROTRUDING NAILS. FOUNDATION STATUS UNKNOWN. 6X6 COLUMNS TOENAILED, CRACKING AND TWISTING WITH UNDERSIZED LAP JOINTS AT 12''. STRINGERS - CRACKING , WEATHERED, INADEQUATELY SUPPORTED, MISSING HARDWARE AT COLUMNS. TREADS / DECK BOARDS - CRACKING, CUPPING, SEVERELY WEATHERED AND DETERIORATING. 2X8 JOIST - OVERSPANNING AT OVER 11'. PLANS AND PERMIT REQUIRED TO REPLACE PORCH SYSTEM. ALL WORK IS SUBJECT TO INSPECTION AND APPROVAL UPON COMPLETION. | 738 S KILBOURN AVE | COMPLAINT | FAILED | View |