Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
TEST G & S ALL ELE | EV008098 | 1617 E 50TH PL | PERIODIC | PASSED | View |
TEST G & S ALL ELE | 5 YEAR SAFETY TEST. | 1617 E 50TH PL | PERIODIC | CLOSED | View |
FILE BLDG REGISTRATION | BLDG. - NOT REGISTERED FROM 2009 THRU 2014. | 1617 E 50TH PL | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | NO CODE DATA PLATE ON CONTROLLERS | 1617 E 50TH PL | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CAT1 ANNUAL SAFETY TEST ON ELEVATORS #1-2 | 1617 E 50TH PL | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT - LAUNDRY ROOM - MISSING SMOKE DETECTOR. | 1617 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE | BOTH STAIRWAYS - STAIR IDENTIFICATIONS AND GEOGRAPICAL LOCATIONS MISSING AT EACH FLOOR ON INTERIOR SIDE OF STAIRWELL AND CORRIDOR WALL (SEC. 13-76-075). | 1617 E 50TH PL | PERIODIC | FAILED | View |
INSTALL EXIT SIGN | BASEMENT: TENANT STORAGE / BIKE ROOM - EXIT AND DIRECTIONAL EXIT SIGNS MISSING. | 1617 E 50TH PL | PERIODIC | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | BOILER ROOM / REAR DOOR INTO BIKE ROOM - MISSING LABEL. TRASH CHUTES AT 1ST, 3RD AND 6TH FLOOR - NOT CLOSING. BOILER ROOM INTERIOR DOOR - BROKEN AND MISSING LABEL (NEW CLASS B DOOR REQUIRED). BASEMENT LAUNDRY ROOM - DOOR ONLY 3/4 HOUR. EMERGENCY II SYSTEM CLOSET - REVERSE CLOSER TO ALLOW DOOR TO SELF-CLOSE. 14TH FLOOR CEILING: BUILT-IN ACCESS HATCH PANEL DOOR, WITH STAIRCASE - MISSING FIRE RATED LABEL. BOILER ROOM REAR EXTERIOR DOOR TO BE EQUIPED WITH PANIC BAR RELEASE PER ARCHITECT'S RECOMMENDATION. | 1617 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE | BOILER / GARBAGE CHUTE ROOM: PROVIDE NON COMBUSTIBLE STAIRWAY SYSTEM FROM SUB-BASEMENT TO BASEMENT LEVEL AT DOORS OPENING INTO STORAGE / BIKE ROOM (SEC. 13-196-570). | 1617 E 50TH PL | PERIODIC | FAILED | View |
2HR SEP FOR STORAGE >100SF | SEPARATE STORAGE ROOMS INSIDE BOILER ROOM AND BIKE ROOM WITH 2-HOUR ENCLOSURE AND CLASS B DOOR ASSEMBLY. PLANS AND PERMIT REQUIRED . | 1617 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE CLASS A FIRE DOOR | ELECTRIC "MAIN" SERVICE DISCONNECT ROOM - DOUBLE SWING CLASS A DOOR HAS LARGE GAP AT BOTTOM, AND MISSING EDGE OVERLAP COVER. | 1617 E 50TH PL | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. - INCOMPLETE MANAGEMENT INFORMATION SIGN POSTED - MISSING MAILING ADDRESS AND CONTACT PHONE NUMBERS. | 1617 E 50TH PL | PERIODIC | FAILED | View |
PIPE OPENING W/NONCOMBUST MATL | PENTHOUSE - PIPE PENETRATIONS SEALED WITH SPRAY FOAM. 14TH FLOOR / TRASH ROOM, AND BASEMENT / LAUNDRY ROOM - UNUSED OPEN PIPE TO BE CAPPED OR REMOVED AND SEAL WITH FIRE CAULK. SPRAY FOAM DRAFT-STOPPING CANNOT BE USED FOR FIRE-STOPPING PENETRATIONS. PROPER FIRE STOPPING MATERIALS SUCH AS FIRE CAULK WITH MINERAL WOOL BACK-UP IS RECOMMENDED. SUBMIT DOCUMENTATION THAT FIRE STOPPING WAS INSTALLED TO MEET RECOGNIZED AGENCY TEST STANDARDS. | 1617 E 50TH PL | PERIODIC | FAILED | View |
1HR ENCL FLR TO FLR SHAFT/DUCT | PENTHOUSE AND ELEVATOR MACHINE ROOM - TRASH CHUTE PIPE SHAFT WITH LARGE CAVITY ON FLOORS. 3RD FLOOR / ELECTRIC CLOSET - HOLE AROUND THE SHAFT. STAIRWELLS - OPENING AROUND THE PIPE PENETRATIONS. CLOSE AND SEAL ALL PENETRATION HOLES WITH PROPER FIRE STOPPING MATERIALS. SUBMIT DOCUMENTATION THAT FIRE STOPPING WAS INSTALLED TO MEET RECOGNIZED AGENCY | 1617 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EXTERIOR BASEMENT TO GRADE STAIRWAY - GUARDRAIL SECTIONS ARE OF "LADDER" TYPE, WITH HORIZONTAL TIES SPACED 18 INCHES APART AND ONLY 36 INCHES HIGH. | 1617 E 50TH PL | PERIODIC | FAILED | View |
CLASS B DOOR IN STAIRWELL | EAST AND WEST STAIRWAYS - CLASS B DOORS WITH ONLY SPRING LOADED HINGE CLOSERS THROUGHOUT. PROVIDE BOTH STAIRWAY CLASS B DOORS WITH HEAVY DUTY 1-1/2 HOUR UL APPROVED DOOR SELF-CLOSING DEVICE. | 1617 E 50TH PL | PERIODIC | FAILED | View |
REMOVE | 14TH FLOOR CEILING: ACCESS PANEL HATCH DOOR, WITH STAIRCASE TO PENTHOUSE MOUNTED ON WOODEN BOARDS - REMOVE AND REPACE WITH NON-COMBUSTIBLE MATERIALS (SEC 15-12-030). | 1617 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE | PROVIDE 2-HOUR ENCLOSURE FOR TRASH CHUTE DISCHARGE SPACE, WITHIN THE BOILER ROOM PER SECTION 15-8-170(A). | 1617 E 50TH PL | PERIODIC | FAILED | View |
PROVIDE | FAILED TO OBTAIN APPROVAL FOR IMPLEMENTATION OF LIFE SAFETY EVALUATION COMPLIANCE PLAN. (13-196-206D) | 1617 E 50TH PL | COMPLAINT | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATAGORY 1 SAFETY TESTS ON CARS #1&2 | 1617 E 50TH PL | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SCHEDULE "FINAL" INSPECTION WITH CITY OF CHICAGO ELEVATOR BUREAU & URBAN ELEVATOR FOR ELEVATOR MODERNIZATION. PERMIT# 100117140 | 1617 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATAGORY 1 SAFETY TESTS ON CARS #1&2 | 1617 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR 2ND FLOOR DOWN HALL CALL FOR PASSENGER ELEVATOR | 1617 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR EMERGENCY LIGHT & ALARM BELL | 1617 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | UPDATE FIRE SERVICE LOG/ MAINTENANCE LOGS | 1617 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATEGORY 1 TEST ON ELEVATORS | 1617 E 50TH PL | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE ANTI-ROTATION DEVICE FOR SHACKLES ON BOTH ELEVATORS | 1617 E 50TH PL | PERIODIC | PASSED | View |
INSTALL | PROPER SIZE DISCHARGE PIPE SAFETY RELIEF #2 FITZ SM. | 1617 E 50TH PL | PERIODIC | CLOSED | View |
REMOVE | DISCHARGE PIPE FROM SAFETY RELIEF, WRONG SIZE, DISCHARGE PIPE CANNOT BE REDUCED. | 1617 E 50TH PL | PERIODIC | CLOSED | View |
REPAIR | LEAKING FITTINGS #7 BRADFORD 12 HWT. | 1617 E 50TH PL | PERIODIC | CLOSED | View |
OWNER OR LICENSED CONTRACTOR | 1617 E 50TH PL | PERIODIC | CLOSED | View | |
FILE BLDG REGISTRATION | NOT REGISTERED 2009-2011 | 1617 E 50TH PL | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | UNIT 3E - SHOE RACK OBSTRUCTING EGRESS. UNIT 2E - CARPET OBSTRUCTING FULL DOOR SWING, MAKING IT DIFFICULT TO OPEN AND CLOSE. | 1617 E 50TH PL | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | EAST AND WEST INTERIOR STAIRWAYS - RAILING AND GUARDRAIL SECTIONS ARE OF "LADDER" TYPE, WITH HORIZONTAL TIES SPACED 18 INCHES APART. GUARDRAIL HEIGHT ONLY 36 INCHES. PERMIT REQUIRED TO REPAIR BOTH STAIRWAYS. | 1617 E 50TH PL | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | WRONG ADDRESS PROVIDED. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS (?), AND BASEMENT. UNVERIFIED DETECTORS AND CONDITIONS. | 1617 E 50TH PL | PERIODIC | FAILED | View |