Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 8:23 PM
PIN: 16234000870000
Property Address: 1850 S DRAKE AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77125
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 36 Violations
Violation Inspector Comments Address Category Status View
DEFECTIVE POWER SERVICE 1850 S DRAKE AVE COMPLAINT FAILED View
BOND AROUND FITTINGS PROVIDE BONDING 1850 S DRAKE AVE COMPLAINT FAILED View
PROPER SIZE OCP OVER FUSING #12 WIRE OR 30 AMP,#14 OR 20 AMP 1850 S DRAKE AVE COMPLAINT FAILED View
CLOSE BOX OPENINGS 1850 S DRAKE AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES MISSING COVERS 1850 S DRAKE AVE COMPLAINT FAILED View
INSTALL COVERS BASEMENT 1850 S DRAKE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE SMOKE DETECTORS TOP OF STAIRS 1850 S DRAKE AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY INADEQUATE TEMPERATURE NO HEAT IN UNIT (1) 64.9 DURING TIME OF INSPECTION 1850 S DRAKE AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NO SUPPLY OF HOT IN UNIT (1) DURING TIME OF INSPECTION 1850 S DRAKE AVE COMPLAINT FAILED View
DEFECTIVE BREAKER DEAD SHORT IN PANEL 1850 S DRAKE AVE COMPLAINT FAILED View
EXPOSED WIRING HEAT TRACE 1850 S DRAKE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER POSTING 1850 S DRAKE AVE COMPLAINT FAILED View
WORK NOT ALLOWED STEEL PICKET AND CHAIN LINK FENCE OVER 5 FEET. REDUCE HEIGHT, REMOVE, OR OBTAIN PERMIT. 1850 S DRAKE AVE COMPLAINT FAILED View
PARAPET SOUTH AND NORTH PARAPET HAS LOOSE AND MISSING MORTAR 1850 S DRAKE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH GRADE TO BASEMENT MISSING HANDRAIL 1850 S DRAKE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY 1850 S DRAKE AVE COMPLAINT FAILED View
RATS RAT HOLES AT REAR YARD 1850 S DRAKE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER I.D. SIGN POSTED 1850 S DRAKE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION WASHED OUT MORTAR 1850 S DRAKE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH ELEVATION MISSING HANDRAILS AT GRADE TO LOWER GRADE 1850 S DRAKE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH 2X8 JOISTS SPANNED AT 13 FEET 2 INCHES MISSING PICKETS THRU-OUT MISSING BOLTS OR STRINGER BEAM PULLING AWAY FROM COLUMN NO BOLTS BEAM TO COLUMN FOOTING STATUS UNKNOWN SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIR OF REAR PORCH 1850 S DRAKE AVE COMPLAINT FAILED View
PROVIDE REAR ELEVATOR MISSING GUTTER (18-29-1101-2-1) 1850 S DRAKE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION UNABLE TO VERIFY DETECTORS OCCUPANCY AND INSPECT FRONT STAIRS BASEMENT 1850 S DRAKE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S I.D SIGN POSTED. 1850 S DRAKE AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR EAST ELEVATION - GATE - DOUBLE KEY LOCK. 1850 S DRAKE AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU SOUTH ELEVATION - AREAWAY CEILING - COVERED WITH WOOD PANELING. 1850 S DRAKE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION - 2 STORY OPEN WIOOD PORCH. 6X6 COLUMNS ERECTED ON TOP OF CONCRETE SLAB,OVERNOTCHED,TWISTED AND PULLING AWAY ON NORTH END AT BEAM TO COLUMN FIRE CUT(1"). RAILINGS ARE LOOSE, TOENAILED TO COLUMNS AND ARE A LADDER TYPE DESIGN ON LANDING. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. 1850 S DRAKE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S I.D SIGN POSTED. 1850 S DRAKE AVE COMPLAINT PASSED View
NO KEY TO USE EXIT DOOR EAST ELEVATION - GATE - DOUBLE KEY LOCK. 1850 S DRAKE AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF COLD AIR COMING THRU DOORS AND BROKEN WINDOWS. 1850 S DRAKE AVE COMPLAINT PASSED View
1HR FLR OVER BSMT, 1 OR 2 DU SOUTH ELEVATION - AREAWAY CEILING - COVERED WITH WOOD PANELING. 1850 S DRAKE AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM WEST ELEVATION - 2 STORY OPEN WIOOD PORCH. 6X6 COLUMNS ERECTED ON TOP OF CONCRETE SLAB,OVERNOTCHED,TWISTED AND PULLING AWAY ON NORTH END AT BEAM TO COLUMN FIRE CUT(1"). RAILINGS ARE LOOSE, TOENAILED TO COLUMNS AND ARE A LADDER TYPE DESIGN ON LANDING. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. 1850 S DRAKE AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT LAUNDRY ROOM-MISSING CARBON MONOXIDE DETECTOR. 1850 S DRAKE AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE BASEMENT LAUNDRY ROOM / WALL MOUNTED GAS FIRED VENTLESS SPACE HEATER BEING USED.(REMOVE). 1850 S DRAKE AVE COMPLAINT FAILED View
PROPER SIZE GRD ELECTRODE COND IMPROPERLY GROUNDED 1850 S DRAKE AVE COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY ALSO PROVIDE PUBLIC PANEL AND METERING TO SERVE BUILDING COMMON AREAS 1850 S DRAKE AVE COMPLAINT FAILED View