The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | 4302 W MONROE ST | COMPLAINT | CLOSED | View | |
OBTAIN OR POST PERMIT | 4302 W MONROE ST | COMPLAINT | CLOSED | View | |
POST OWNER/MANAGERS NAME/# | POST OWNER INFO | 4302 W MONROE ST | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALLS ERODED MORTAR LOOSE BRICKS | 4302 W MONROE ST | COMPLAINT | FAILED | View |
CHIMNEY | ERODED MORTAR LOOSE BRICKS | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY OPEN WOOD PORCH-COLUMNS SPLIT AND OVERNOTCHED.BEAMS NOTCHED INTO COLUMN AND SEPERATING.STRINGERS UNDERSIZED,OVERCUT,NO POSITIVE CONNECTION AT LANDINGS OR COLUMNS[ATTATCHED WITH NAILS].JOISTS SPACED 30" ON CENTER.6X6X10 BEAMS OVERSPANNED.RAIL SECTIONS AT 36" DEFLECT EASILY UNDER LOAD WITH FAILING CONNECTIONS.SUBMIT PLANS AND OBTAIN PERMIT TO REPAIR OR REPLACE PORCH. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | APT. 1: LIVING ROOM AND BEDROOM TEMPERATURES ARE 43.6F AND 38F RESPECTIVELY. HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED - FURNACE BROKEN. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | APT. 1 - TENANT USING COOKING STOVE AS HEATING DEVICE. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | MOST APARTMENT, INCLUDING APT. 1 - WINDOWS AND DOORS ARE DRAFTY, WITH AIR SEEPAGE. KITCHEN AND BEDROOM WINDOW PANES MISSING. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | APT. 1 - FURNACE - BROKEN AND OUT OF SERVICE. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | APT. 1 - BATHROOM - HOT WATER PIPE BUSTED - NO HOT WATER SUPPLIED TO THE FIXTURE, WITH EXCEPTION OF KITCHEN. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | APT. 1 - BATHROOM - NO COLD WATER SUPPLIED TO THE FIXTURE, WITH EXCEPTION OF KITCHEN. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION CONCRETE STAIRS GRADE TO 1ST RISERS UNEVEN HEIGHTS. GRADE TO BASEMEWNT SOUTH ELEVATION NO HANDRAIL. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTH ELEVATION, GUARDRAIL MISSING AROUND BASEMENT | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR CORNICE | SOUTH ELEVATION RUSTED LARGE HOLES IN CORNICE. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
PARAPET | PARAPET, ALL ELEVATIONS LOOSE BRICKS,WASHED OUT MORTAR.CHIMNEY ERODED MORTAR,LOOSE BRICKS 9SOUTH ELEVATION) | 4302 W MONROE ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION,LOOSE CONCRETE SIDE WALK. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | SOUTH ELEVATION,ENTRANCE DOOR LOCK AND KNOB MISSING. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | NORTH ELEVATIONS BASEMENT DOOR BOTTOM RAT DETERIORATION LOCK AND KNOB MISSING,FRAME ROTTED ON BASEMENT DOOR | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | ALL ELEVATIONS BROKE PANES,BASEMENT EAST GLASS BLOCKS CRACKED.WEST AND EAST 1ST TO 3RD,MISSING PANES. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | ALL ELEVATIONS 1ST TO 3RD AIR SEEPAGE FROM WINDOWS | 4302 W MONROE ST | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | APARTMENT 1-2-3 CEILINGS HAVE LARGE HOLES AND WATER DAMAGE IN BATHROOM AND KITCHENS. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
STOP LEAKING WATER | APARTMENTS 1-2-3- BASEMENT/ ABATE WATER LEAKS THRUOUT BUILDING. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | APARTMENT 3 - SMOKE DETECTOR MISISNG IN LIVING ROOM AND BASEMENT. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT CARBON MONOXIDE DETECTOR MISSING. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR DOOR FRAME, MULLION | 1-2-3- FRONT INTERIOR DOORS TO APARTMENTS HAVE GAPS AROUND PERIMETER, ALSO LOPSIDED INSTALLATION | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | APARTMENT 1- MAIN HALLWAY REAR KITCHEN AND BATH FLOORS VERY BOUNCY,ROTTED WOOD,SAGGING DANGEROUSLY APARTMENT 2 & 3 BATH AND KITCHEN FLOORS ROTTED AND SAGGING 1- WEAK UNDER LOAD - PERMITS REQUIRED FOR REPAIRS TO ALL FLOORS. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | APARTMENT 1-2- 3 BATH AND KITCHEN TILES LOOSE AND MISSING. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRS 1ST TO 2ND HANDRAIL MISSING 1ST TO 3RD TREADS WEAK UNDER LOAD,WINDERS AT ALL LEVELS LEANING,BOUNCY EXCESSIVELY UNDER LOAD.SLOPING TREADS 1ST TO 3RD. MISSING BALLUSTERS AT ALL LEVELS 2ND TO 3RD. PLAINS AND PERMITS REQUIRED FOR REPAIRS OF INTERIOR STAIR SYSTEM | 4302 W MONROE ST | COMPLAINT | FAILED | View |
CARPETING | INTERIOR STAIRS,1ST TO 3RD BADLY SOILED CARPET IS RIPPED AT TREAD EDGES. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | INTERIOR VESTIBULE TO 3RD GARBAGE STREWN ABOUT UNUSED DOORS ON 2ND FLOOR LANDING,BASEMENT HAS GARBAGE AND DEBRIS | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | BASEMENT STANDING SEWER WATER | 4302 W MONROE ST | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | BASEMENT NOXIOUS ODOR EMANATING FROM WITHIN. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | APARTMENT 1 BROKE FAUCETS IN BATHTUB AND KITCHEN | 4302 W MONROE ST | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | LOOSE TUB SURROUND IN APARTMENT 1 / CEILING HAS LARGE 3X8"SECTION. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
RATS | APARTMENT 1 RAT HOLES UNDER KITCHEN SINK. NORTH ELEVATION PERIMETER. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
ROACHES | ROACH INFESTATION EVIDENT THR-OUT BUILDING | 4302 W MONROE ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | VIEWING DEVICES MISSING ALL APARTMENTS | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NORTH ELEVATION ENTIRE FOUNDATION WALL COLLASPED UNDER NEATH PORCH. 4X8 FOOT SECTION MISSING FROM WALL | 4302 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH ELEVATION REAR 3 STORY WOOD PORCH COLUMNS SPLIT,OVER NOTCH, 12" LAP JOINTS.COLUMNS ARE SEPARATING AT JOINT CONNECTIONS.STRINGERS ARE OVERCUT BASEMENT TO 3RD,BASEMENT LANDING IS PLYWOOD. GUARDRAILS ARE 36" HEIGHT. 2X8 JOISTS SPAN 20 FEET ARE 20" ON CENTER. COLUMNS TOE NAILED, PICKETS MISSING ALL LEVELS ON GUARDRAILS. PLANS AND PERMITS REQUIRED TO REPLACE REAR PORCH. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | APARTMENTS 2-3 NO HOT WATER PROVIDED | 4302 W MONROE ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | APARTMENTS 2-3 NO HEAT PROVIDED GAS SHUT OFF | 4302 W MONROE ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMITS AUTHORING USING 3-DWELLING UNIT BUILDING AS ROOMING HOUSE.APARTMENT 1-2-3- ALL BEDROOMS ARE BEING RENTED SEPARATELY AS ROOMS. | 4302 W MONROE ST | COMPLAINT | FAILED | View |
MAINTAN BLDG IN SAFE CONDITION | 4302 W MONROE ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 4302 W MONROE ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 4302 W MONROE ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 4302 W MONROE ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 4302 W MONROE ST | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | VIOLATION CLOSED PER PCR 1180 | 4302 W MONROE ST | COMPLAINT | CLOSED | View |
VACANT BUILDING - REGISTER | 4302 W MONROE ST | COMPLAINT | CLOSED | View | |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR AND EXTERIOR ALTERATIONS TO AN EXISTING 3 STORY MASONRY MULTI UNIT DWELLING INCLUDING BUT NOT LIMITED TO 1. REBUILDING PARAPET WALLS @ EAST & WEST ELEVATIONS 2. ERECTING NEW PARTITIONS @ 1ST 2ND & 3RD FLOORS 3. REBUILDING MASONRY GARAGE IN REAR YARD | 4302 W MONROE ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL A BUILDING PERMIT IS ISSUED 14A-3-306 14A-4-401 14A-4-411 | 4302 W MONROE ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | NO CHIMNEY CAP | 4302 W MONROE ST | COMPLAINT | FAILED | View |