Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | EAST STAIRS TO BASEMENT NO RAILING/EAST STAIRS TO 1-STRINGERS SEPERATED AND SCABBED FROM DECKING. | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
INSTALL DOOR VIEWING DEVICE | BASEMENT UNIT-2ND FLOOR | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | EAST STAIRS TO 2 AT TOP/NORTH STAIRS TO 1 AT TOP | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
CARPETING | EAST STAIRS TO 2-LOOSE/MISSING CARPETING | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | WEST STAIRS TO BASEMENT-NO RAILING | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | FOR PARTION FORMING WALLS, INSTALLATION OF KITCHEN AND BATHROOM IN BASEMENT-ORIGINAL 2 DWELLING UNIT BUILDING-CURRENTLY 3 DWELLING UNITS. | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
STAIRWELL ENCLOSURE - BASEMENT | NORTH STAIRS TO BASEMENT-NO DOOR AT TOP OF STAIRS. | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT-1/2" DRYWALL/NO SEPERATION AT NORTH STAIRS AT TOP OR BOTTOM-NO DOORS. | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
NATURAL LIGHT NEEDED | BASEMENT-NOT FULL SIZE WINDOWS | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
PAINT SHUT | BASEMENT NOT FULL SIZE WINDOWS. | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
HEATING PLANT ENCLOSURE | BASEMENT-BOILER ROO-1/2" DRYWALL ON 1 SIDE ONLY-OTHER SIDE EXPOSED FRAMING NOT ONE HOUR FIRE RATED. ALSO AT BOILER ROOM-EXPOSED JOISTS-NO FIRE SEPERATION. | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |
RATS | 07-00848350 EVIDENCE OF RODENT IN APTS. | 2550 N HAMLIN AVE | COMPLAINT | CLOSED | View |
ROACHES | EVIDENCE OF ROACHES THRU-OUT BUILDING. | 2550 N HAMLIN AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM WITH OUT BOLTS IN LEDGER BOARD ON SECOND AND 1ST FLOOR, NO BOLTS IN STRINGERS TO SUPPORT POST. NO BOLTS BEAM TO COLUMN CONNECTIONS, NO VISIBLE FOOTING. REQUIRE PERMITS FOR ALL REPAIRS. | 2550 N HAMLIN AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | BROKEN OR MISSING SCREENS THRU-OUT BUILDINGS. | 2550 N HAMLIN AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | NO WORKING SMOKE DETECTORS IN HALLWAYS. | 2550 N HAMLIN AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT. | 2550 N HAMLIN AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR EXTEIOR 2 STORY PORCH/ COLUMNS- BEAM FIRECUT, AND OUTSIDE BEAM NOTCHED IN AT ADJACENT LOCATIONS WITH ONLY 1+1/2 INCHES REMAINING. SOME FIRECUTS INTO COLUMNS 3 INCHES DEEP. UNDERSIZED 6X6 BEAMS SPAN 11 FEET- WEAK, AND SAGGING. UNDERSIZED SINGLE OUTSIDE 2X10 STAIR HEADER LOAD TRANSFER BEAMS SPAN 12 FEET 6 INCHES- WEAK AND SAGGING. 4X4 COLUMNS WITH 1+1/2 X 2 INCH NOTCH. UNDERSIZED 2X8 DECK JOISTS SPAN 12 FEET.STRINGERS AT WINDER SECTION JOINTS- MISSING COLUMNS. STRINGERS - BROKEN AND FASTENED TO COLUMNS WITH NAILS ONLY. UNEVEN RISER HEIGHTS RANGE FROM 4 TO 7 INCHES. PLANS, AND PERMIT REQUIRED FOR ALL REPAIRS TO REAR EXTERIOR 2 STORY PORCH. | 2550 N HAMLIN AVE | COMPLAINT | PASSED | View |