Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR STAIR EAST STAIRS TO BASEMENT NO RAILING/EAST STAIRS TO 1-STRINGERS SEPERATED AND SCABBED FROM DECKING. 2550 N HAMLIN AVE COMPLAINT PASSED View
INSTALL DOOR VIEWING DEVICE BASEMENT UNIT-2ND FLOOR 2550 N HAMLIN AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS EAST STAIRS TO 2 AT TOP/NORTH STAIRS TO 1 AT TOP 2550 N HAMLIN AVE COMPLAINT PASSED View
CARPETING EAST STAIRS TO 2-LOOSE/MISSING CARPETING 2550 N HAMLIN AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM WEST STAIRS TO BASEMENT-NO RAILING 2550 N HAMLIN AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR FOR PARTION FORMING WALLS, INSTALLATION OF KITCHEN AND BATHROOM IN BASEMENT-ORIGINAL 2 DWELLING UNIT BUILDING-CURRENTLY 3 DWELLING UNITS. 2550 N HAMLIN AVE COMPLAINT PASSED View
STAIRWELL ENCLOSURE - BASEMENT NORTH STAIRS TO BASEMENT-NO DOOR AT TOP OF STAIRS. 2550 N HAMLIN AVE COMPLAINT PASSED View
SEPARATION OF DWELLING ADEQUAT BASEMENT-1/2" DRYWALL/NO SEPERATION AT NORTH STAIRS AT TOP OR BOTTOM-NO DOORS. 2550 N HAMLIN AVE COMPLAINT PASSED View
NATURAL LIGHT NEEDED BASEMENT-NOT FULL SIZE WINDOWS 2550 N HAMLIN AVE COMPLAINT PASSED View
PAINT SHUT BASEMENT NOT FULL SIZE WINDOWS. 2550 N HAMLIN AVE COMPLAINT PASSED View
HEATING PLANT ENCLOSURE BASEMENT-BOILER ROO-1/2" DRYWALL ON 1 SIDE ONLY-OTHER SIDE EXPOSED FRAMING NOT ONE HOUR FIRE RATED. ALSO AT BOILER ROOM-EXPOSED JOISTS-NO FIRE SEPERATION. 2550 N HAMLIN AVE COMPLAINT PASSED View
RATS 07-00848350 EVIDENCE OF RODENT IN APTS. 2550 N HAMLIN AVE COMPLAINT CLOSED View
ROACHES EVIDENCE OF ROACHES THRU-OUT BUILDING. 2550 N HAMLIN AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR PORCH SYSTEM WITH OUT BOLTS IN LEDGER BOARD ON SECOND AND 1ST FLOOR, NO BOLTS IN STRINGERS TO SUPPORT POST. NO BOLTS BEAM TO COLUMN CONNECTIONS, NO VISIBLE FOOTING. REQUIRE PERMITS FOR ALL REPAIRS. 2550 N HAMLIN AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS BROKEN OR MISSING SCREENS THRU-OUT BUILDINGS. 2550 N HAMLIN AVE COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS NO WORKING SMOKE DETECTORS IN HALLWAYS. 2550 N HAMLIN AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION NO ENTRY TO BASEMENT. 2550 N HAMLIN AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR EXTEIOR 2 STORY PORCH/ COLUMNS- BEAM FIRECUT, AND OUTSIDE BEAM NOTCHED IN AT ADJACENT LOCATIONS WITH ONLY 1+1/2 INCHES REMAINING. SOME FIRECUTS INTO COLUMNS 3 INCHES DEEP. UNDERSIZED 6X6 BEAMS SPAN 11 FEET- WEAK, AND SAGGING. UNDERSIZED SINGLE OUTSIDE 2X10 STAIR HEADER LOAD TRANSFER BEAMS SPAN 12 FEET 6 INCHES- WEAK AND SAGGING. 4X4 COLUMNS WITH 1+1/2 X 2 INCH NOTCH. UNDERSIZED 2X8 DECK JOISTS SPAN 12 FEET.STRINGERS AT WINDER SECTION JOINTS- MISSING COLUMNS. STRINGERS - BROKEN AND FASTENED TO COLUMNS WITH NAILS ONLY. UNEVEN RISER HEIGHTS RANGE FROM 4 TO 7 INCHES. PLANS, AND PERMIT REQUIRED FOR ALL REPAIRS TO REAR EXTERIOR 2 STORY PORCH. 2550 N HAMLIN AVE COMPLAINT PASSED View