Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PARAPET | NORTH AND SOUTH PARAPET WALLS - WASHED OUT MORTAR. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT ONE STORY PORCH.COLUMNS - SHIFTING BRICKS AND WASHED OUT MORTAR.UNDERZISED 2"X8" DECK JOISTS SPAN 10'-8".DECK JOISTS ONLY FACE NAILED TO RIM JOIST.LEDGER BOARD - FASTENED TO EXTERIOR WALL WITH NAILS ONLY.STRINGERS FASTENED TO JOISTS BLOCKING WITH NAILS ONLY.GUARD RAILINGS HEIGHT - ONLY 32".HANDRAILS HEIGHT - ONLY 26".PLAN AND PERMIT ARE REQUIRED TO REPAIR OR REPLACE FRONT PORCH. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
RATS | BUILDING INFESTED WITH RATS, INCLUDING BASEMENT APT. | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT APT. MISSING CARBON MONOXIDE DETECTOR. | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD - REFUSE AND JUNK ACCUMULATION. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | 1ST AND 2ND FLOOR APTS. - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
RATS | BUILDING INFESTED WITH RATS, INCLUDING BASEMENT APT. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | BASEMENT APT. MISSING CARBON MONOXIDE DETECTOR. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD - HIGH WEEDS AND GRASS. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION/ EXTERIOR WALL- FRACTURED MASONRY, WITH WASHED OUT MORTAR. NORTH ELEVATION/ EXTERIOR WALL- SECTIONS OF SIDING MISSING. | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION/ EXTERIOR WALL- FRACTURED MASONRY, WITH WASHED OUT MORTAR. NORTH ELEVATION/ EXTERIOR WALL- SECTIONS OF SIDING MISSING. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT EXTERIOR 1 STORY PORCH- FRACTURED MASONRY COLUMNS, OUT OF PLUMB AND WITH WASHED OUT MORTAR. UNDERSIZED 2X8 DECK JOISTS SPAN 11 FEET. ALL JOIST CONNECTIONS FASTENED WITH NAILS ONLY. STRINGERS- BROKEN AND SCABBED SECTIONS. PLANS AND PERMIT REQUIRED TO REPLACE: FRONT EXTERIOR 1 STORY PORCH. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS, AND REAR ENCLOSED PORCH. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
CHIMNEY | CHIMNEY - BRICKS SPALLED WITH WASHED OUT MORTAR. | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH ELEVATION/ PARAPET WALLS - BRICKS SPALLED WITH WASHED OUT MORTAR. FRONT PARAPET WALL - CENTER PARAPET OUT OF PLUMB, WALL LEANS INWARD. PERMIT IS REQUIRED FOR ALL MASONRY REPAIRS. | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | PLANS FOR PERMIT # 100602611 ISSUED 7/10/2015 TO REPLACE FRONT PORCH NOT AVAILABLE FOR INSPECTOR'S REVIEW AT TIME OF INSPECTION. SUBJECT TO FIELD INSPECTION AND APPROVAL REQUIRED. | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO ENTRY AND NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | HEATING SYSTEM OFF AT TIME OF INSPECTION ROOM TEMP 1) BEDROOM 64 DEGREE'S 2) BEDROOM 68 DEGREE'S KITCHEN 90 DEGREE'S LIVING RM 82 DEGREE'S BATH RM 60 DEGREE'S BASEMENT APT | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | FURNACE OUT AT TIME OF SERVICE (BASE APT) | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | USING STOVE AS HEATING DEVICE | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | STOP ALL WORK UNTIL PERMIT IS OBTAINED SEC (13-12-080) AND (13-32-035) | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REPAIR & REPLACEMENT OF PLASTER AND LATH ON ALL 3 FLOORS AND BASEMENT | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - MISSING OWNER'S ID. SIGN. | 1008 N HAMLIN AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT GATES - DOUBLE KEYED LOCKED. | 1008 N HAMLIN AVE | COMPLAINT | FAILED | View |