The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN NOT POSTED. | 7517 S STEWART AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | BUILDING REAR 2 STORY WOOD PORCH, 2ND FLOOR SINGLE 2X8X12 BEING USED FOR BEAM TO CARRY THE FLOOR JOISTS, HAS A LARGE DOWNWARD SAG ON IT. OUTSIDE COLUMNS ARE DOUBLE CUT FOR BEAM AND RIM JOISTS. 4X4 COLUMN USED TO SUPPORT PART OF 2ND FLOOR DECK AND STAIRS MID-LANDING HAS BEEN CUT INTO AT SEVERAL AREAS. LEDGER BOARDS ON 1ST AND 2ND FLOOR ONLY ATTACHED WITH NAILS, 2ND FLOOR LEDGER AT SOUTH CORNER IS PULLING AWAY FROM THE WALL. GUARD RAILS ARE OVER SPANNED AND ATTACHED TO WALLS WITH NAILS ONLY. STRINGERS ATTACHED WITH NAILS ONLY AND BRACED AGAINST FLOOR JOISTS. DANGEROUS PLANS AND PERMIT REQUIRED FOR REPLACEMENT. | 7517 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH FLOOR JOISTS ARE OVER 12 FEET IN LENGTH AND ATTACHED WITH NAILS ONLY. PERMIT ONLY | 7517 S STEWART AVE | COMPLAINT | FAILED | View |
OBTAIN OR POST PERMIT | 7517 S STEWART AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 7517 S STEWART AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 7517 S STEWART AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 7517 S STEWART AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 7517 S STEWART AVE | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | VIOLATION CLOSED PER PCR 1180 | 7517 S STEWART AVE | COMPLAINT | CLOSED | View |
REPLACE HOUSE DRAIN PIPING | SEWAGE BACKING INTO CATCH BASIN 11-16-020)(18-59-301.3) | 7517 S STEWART AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | INTERIOR AND REAR YARD 18-29-705.1 THUR 11) | 7517 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR CATCH BASIN | CAN SEAL IN PRESENT CONDITION 18-29-1003. 1 THRU 4) | 7517 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 7517 S STEWART AVE | COMPLAINT | CLOSED | View | |
ARRANGE PREMISE INSPECTION | FIRST FLOOR, BASEMENT AND RAR YARD (18-29-601.2.3) | 7517 S STEWART AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 18-29-106-2) | 7517 S STEWART AVE | COMPLAINT | FAILED | View |
CLEAN CATCH BASIN | REAR YARD LOCATION (18-29-1003.4) | 7517 S STEWART AVE | COMPLAINT | FAILED | View |