Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | FRONT ELEVATION/ EXTERIOR WALL - ROTTED WOOD SECTIONS WITH PEELING PAINT.NORTH AND EAST ELEVATIONS/ FOUNDATION WALLS - SPALLING BRICKS WITH WASHED OUT MORTAR; CRACKED AND MISSING PARGING. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | ALL ELEVATIONS/ ROOF EAVES - ROTTED WITH PEELING PAINT. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | FRONT YARD - ACCUMULATION OF USED LUMBER, CONSTRUCTION MATERIAL, CHAIRS AND A LAWNMOWER. FIRE HAZARD. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | FRONT YARD - OVERGROWN AND HIGH WEEDS. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT AND EAST ELEVATION/ BASEMENT AND ENTRANCE DOOR - ROTTED AND CHIPPED WOOD. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | FRONT 1-STORY METAL AND WOOD BALCONY/ UNDERSIZED 2X8 DECK JOISTS SPAN 10 FEET. METAL RAILINGS - LADDER TYPE WITH 10 INCHES BETWEEN MEMBERS.PLANS AND PERMIT REQUIRED TO REPAIR BALCONY. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION/ BASEMENT WINDOW - BOARDED UP. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | EAST ELEVATION/ WINDOW FRAMES - ROTTED WITH PEELING PAINT. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | EAST ELEVATIONS/ WINDOWS - MISSING SCREENS. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | EAST ELEVATION/ WOOD FENCE - BROKEN BOARDS. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS, LAYOUT AND OCCUPANCY.UNABLE TO INSPECT INTERIOR STAIRWAYS AND REAR PORCH. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | FRONT WROUGHT IRON 67 INCH HIGH FENCE - BUILT WITHOUT A PERMIT. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | WEST ELEVATION - ROTTED EAVES | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH ATTIC ELEVATION - RIOTTED WINDOW FRAME, BROKEN WINDOWS.BASEMENT FRONT ,NORTH ROOM - ROTTED WINDOW FRAME/CASING BOARDS. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT BASEMENT STAIRS - MISSING HANDRAIL, UNEVEN RISER HEIGHTS.FRONT GRADE TO 1ST FLOOR - LOOSE TREADS AND RISERS, BOTTOM STEPS SINKING AT CORNER.REAR GRADE TO 1ST FLOOR - LARGE 6" GAP BETWEEN STAIRS AND WALL. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | PROVIDE CONDITIONS ASSESMENT REPORT OF REAR 1 STORY ROOF STRUCTURE, BASEMENT AND 1ST FLOOR SYSTEMS PER SECTIONS (14X-1-1-4.1, 104X-1-104.2, 14X.1.104.3, 14X-1-104.4, 14A-4-411.1, 14A-4-412.1.1, 14A-6-603.5)PLANS AND PERMITS ARE REQUIRED PER REPORT FOR REPAIRS/REBUILD . ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL (SEC 14A-4-401.1) | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | BASEMENT - SOFT AND SINKING FLOOR SYSTEM AT VARIOUS LOCATIONS.CEILING AT LAUNDRY ROOM - 1ST FLOOR JOISTS BRACED WITH A PLANK AND FLOOR SCREW JACK . | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR 1STORY ROOF - UNDERSIZED RAFTERS WITH A 2X10 PIECE SUPPORTING A SECTION , NAILED TO A 2X4 COLUMN. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT PERMIT.( SEC 14-3-301.1 ,14A4-413.1, 14A-4-413.8.1 | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT OR RESTORE TO THE ORIGINAL STATE.(14A-4-401.1 THRU 14A-4-404.22, 14A-4-410.1, 14A-4-411 THRU 14A-4-411.3, TABLE 14A-12-1204.2) | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
RATS | INTERIOR OF BUILDING - RAT DROPPINGS OBSVERVED AT LAUNDRY ROOM. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT, 1ST FLOOR FRONT AND REAR STAIRWAYS - MISSING SMOKE ALARMS. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND 1ST FLOOR - MISSING CARBON MONOXIDE ALARMS. | 2047 N LECLAIRE AVE | COMPLAINT | FAILED | View |