The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING - ADDRESS PAINTED OVER, NOT VISIBLE FROM THE STREET. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | NORTH ELEVATION ABOVE ENTRY - ROTTED WOOD FACIA. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
CHIMNEY | EAST ELEVATION CHIMNEY - SPALING BRICKS AND WASHED OUT MORTAR. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 2ND FLOOR UNITS ENTRY DOORS - MISSING PEEP HOLES. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH -WOOD IS DRY ROTTED THROUGHOUT.6X6 COLUMNS DOUBLE NOTCHED.4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET IN HEIGHT, COLUMNS ALSO NOTCHED.2X10 JOIST SPAN 15 FEET.STRINGERS WRAPPED UNDER HEADERS AND NAILED TO JOIST.6X6 BEAMS SPAN 7 FEET, MISSING TIE STRAPS AT BUILDING CONNECTION AND NAILED TO COLUMNS.GUARDRAILS ONLY 32 INCHES IN HEIGHT WITH LADDER TYPE PICKETS.PLANS AND PERMIT REQUIRED. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | 2923 UNIT 1 REAR DOOR - MISSING CLOSER. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS TO BASEMENT - MISSING HANDRAIL. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | REAR PORCH 1ST FLOOR - STORAGE CLOSET CONSTRUCTED UNDER STAIRS. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST AND SOUTH ELEVATION - SILLS - WASHED OUT MORTAR. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
CHIMNEY | EAST ELEVATION - CHIMNEY - SPALLING BRICKS AND WASHED OUT MORTAR. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | EAST ELEVATION - CHIMNEY CAP - WASHED OUT MORTAR. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | GAINED ENTRY TO HALLWAY BUT NOT TO 2919 1ST FLOOR TO VERIFY COMPLAINT OF WATER LEAKING AND BLACK MOLD ON WALLS.UNVERIFIED DETECTORS AND CONDITIONS. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH ELEVATION BACK PORCH - CLUTTERED WITH STORAGE. | 2919 W ROSEMONT AVE | COMPLAINT | FAILED | View |